| Plan Review Stops For Permit 16111038 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-01-05 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-05 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2017-01-05 08:08:53 | APPROVED WITH EXCEPTION | | | 1) PROVIDE SHORING AND OTHER SAFEGUARDS TO PROTECT | | | ADJACENT FOUNDATIONS AND PROPERTY DURING POOL | | | CONSTRUCTION. FBC 3304.1 AND 3307.1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-14 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-14 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2016-12-14 09:41:01 | THE ELECTRICAL AND PLUMBING SUB-PERMIT APPLICATIONS ARE | | | REQUIRED TO BE SUBMITTED BEFORE THE POOL PERMIT CAN BE | | | ISSUED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-01-05 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-05 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-14 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-14 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2016-12-14 09:07:09 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT TWO SETS OF MANUFACTURER'S SPECIFICATIONS | | | WITH ELECTRICAL REQUIREMENTS FOR THE ELECTRIC HEAT PUMP | | | POOL HEATER. FBC 107.2.1 | | | | | | 2) SUBMIT TWO SETS OF ELECTRICAL LOAD CALCULATIONS THAT | | | SHOW THE EXISTING ELECTRICAL IS ADEQUATE FOR THE NEW | | | POOL EQUIPMENT. THE NAME, LICENSE NUMBER AND SIGNATURE | | | OF THE PERSON PROVIDING THE CALCULATIONS ARE REQUIRED | | | TO BE ON THEM. FBCR-E3602.2 | | | | | | 3) AN ELECTRICAL SUB-PERMIT IS REQUIRED. FBC 105.1 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-12-13 |
Time |
04:17 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-12-13 |
Time |
04:15 |
Sent To |
|
|
| Notes |
| 2016-12-13 04:17:00 | THERE IS NO GAS HEATER ON THIS POOL. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-12-12 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-12-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-01-05 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-04 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2017-01-04 14:48:58 | SENT TO TKL DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-14 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-11-23 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2016-12-12 13:41:36 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-01-05 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-01-05 |
Time |
06:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-12-13 |
Time |
04:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-12-13 |
Time |
03:46 |
Sent To |
|
|
| Notes |
| 2016-12-13 04:14:47 | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN | | | DRAINS, HEAT PUMP, POOL PUMP AND PUMP CURVE. WPB AMEND. | | | TO FBC SEC. 107.2.1. | | | 2) THE HEAT PUMP SHALL COMPLY WITH THE 2014 FBC ENERGY | | | SEC. R403.9.1.2. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-12-12 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-12-12 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2016-12-12 16:40:26 | 12/12/16- PASSED | | | | | | 1. LANDSCAPE PERMIT IS NOT REQUIRED | | | 2. NO TREES WILL BE REMOVED | | | 3. SF14-C2 HISTORIC | | | 4. SIDE SETBACK IS 5FT. MEETING THE 5FT. REQUIREMENT | | | 5. REAR SETBACK IS 8FT. 9IN. MEETING THE 5FT. | | | REQUIREMENT | | | 6. POOL EQUIPMENT IS NOT IN A REQUIRED SETBACK | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|