Plan Review Details - Permit 16110992
Plan Review Stops For Permit 16110992
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-02-08 Cont ID  
Sent By jgomez Date 2017-02-08 Time 18:04 Rev Time 0.00
Received By jgomez Date 2017-02-08 Time 16:45 Sent To  
Notes
2017-02-08 17:37:37BUILDING REVIEW APPROVED WITH PROVISO:
 1- ENERGY CALCULATIONS: CONTRACTOR TO FILL THE ENERGY
 PERFORMANCE LEVEL (EPL) DISPLAY CARD.
 2- PROVIDE PRODUCT APPROVAL FOR: A) SLIDING GLASS
 DOORS. B) WINDOW. C) WINDOW MULLION IF USED. D) SIMPSON
 STRUCTURAL CONNECTOR H10S. NOTE: FLORIDA PRODUCT
 APPROVAL "F25" SPECIFIED ON SHEET 03 IS NOT VALID.
 FLORIDA PRODUCT APPROVALS LISTED ON SHEET D-1 ARE NO
 CURRENT. OR DESIGNER OF RECORD TO LIST EACH FLORIDA
 PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED
 CONNECTOR.
 3- DESIGNER OF RECORD TO APPROVE IN WRITING ABOVE
 PRODUCT APPROVALS.
 4- TRUSS PACKAGE: A) TRUSS ENGINEER TO PROVIDE ORIGINAL
 SIGNATURE (NOT COPY). CHAPTER 471 FLORIDA STATUTE. B)
 COVER PAGE IS MISSING THE INFORMATION OF THE DESIGN
 PROFESSIONAL OF RECORD. FAC SEC. 61G15-31.003. C) NEED
 THE TITLE BLOCK OF THE TRUSS ENGINEER ON EACH DRAWING.
 FAC SEC. 61G15-31.003. D) DESIGN PROFESSIONAL OF RECORD
 TO REVIEW AND APPROVE ALL TRUSS DRAWINGS PRIOR TO
 SUBMITTAL. FAC SEC. 61G15-31.003.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-02-02 Cont ID  
Sent By jgomez Date 2017-02-02 Time 07:57 Rev Time 0.00
Received By jgomez Date 2017-02-01 Time 18:19 Sent To  
Notes
2017-02-01 18:49:38RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
  
  
 NOTE:
 OLD SETS WERE VOIDED. SHEETS 03 AND E-1 WERE REVISED
 BUT THEY WERE NOT REPLACED BY THE OLD ONES. ONE OF THE
 VOIDED SETS DON'T HAVE THE ARCHITECT'S SEAL AND
 SIGNATURE. PLEASE PROVIDE TWO COMPLETE SETS SIGNED AND
 SEALED FOR PROPER PROCESSING.
  
  
  
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 2- REVISE ENERGY CALCULATIONS SUBMITTED:
 A) OWNER OR LEGALLY DESIGNATED AGENT NEED TO CERTIFY AT
 THE BOTTOM OF THE FORM AS REQUIRED BY SEC. R103.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). NOTE:
 PERMIT CAN NOT BE ISSUED WITHOUT THE OWNER'S
 CERTIFICATION.
  
 B) ITEM #1 IS INCORRECT. THIS IS NOT NEW CONSTRUCTION.
 THE CALCULATIONS ARE DONE FOR THE ENTIRE HOUSE., THIS
 IS AN EXISTING CONSTRUCTION PLUS THE ADDITION. REVISE
 AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C) ITEM # 6 IS INCORRECT. ACCORDING TO PLANS (SHEET 01)
 THE EXISTING LIVING AREA IS 1945 S.F. AND THE LIVING
 ROOM EXTENSION IS 351 S.F. THEREFORE, THE TOTAL AREA IS
 2296 S.F. NOT 1967 S.F.. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) ITEM #8 IS INCORRECT. ACCORDING TO PLANS THERE IS NO
 CRAWLSPACE. REVISE AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 E) PROVIDE THE NAME (NOT JUST THE SIGNATURE) OF THE
 PERSON WHO PREPARED THE ENERGY CALCULATIONS AS REQUIRED
 BY SEC. R405.4.2 FBC-ENERGY CONSERVATION.
  
 F) ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 IS INCORRECT.
 THERE ARE NOT SHINGLES ON THIS HOUSE. SEE PLANS AND
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 NOTE:
 LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL
 BE REQUIRED, WHEN ENERGY CALCULATIONS ARE NOT USING THE
 DEFAULT FACTOR FOR GLAZING.
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) SLIDING GLASS WINDOWS AS SHOWN ON PLANS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 B) WINDOWS AS SHOWN ON PLANS.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
 C) SIMPSON STRUCTURAL CONNECTOR H10S AS SPECIFIED ON
 PLANS. NOTE: FLORIDA PRODUCT APPROVAL "F25" SPECIFIED
 ON SHEET 03 IS NOT A VALID FLORIDA PRODUCT APPROVAL
 NUMBER. REVISE AS REQUIRED. ALSO, FLORIDA PRODUCT
 APPROVALS LISTED ON SHEET D-1 ARE NO CURRENT. UPDATE TO
 THE CURRENT 2014 CODE.
 NOTE: JAX APEX TECHNOLOGY COVER PAGE OF REPORT NO
 SIM201501 SUBMITTED IS NOT AN OFFICIAL PRODUCT APPROVAL
 AND IT DOESN'T LIST SPECIFIED CONNECTORS. PROVIDE
 FLORIDA PRODUCT APPROVAL (OR MIAMI-DADE) COVER PAGE AND
 PAGE SHOWING THE SPECIFIED CONNECTOR OR DESIGNER OF
 RECORD TO LIST EACH FLORIDA PRODUCT APPROVAL NUMBER
 NEXT TO EACH SPECIFIED CONNECTOR.
  
 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ABOVE PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1
 CITY AMENDMENTS.
  
 5- TRUSS PACKAGE SUBMITTED:
 A) ENGINEER TO PROVIDE ORIGINAL SIGNATURE (NOT COPY) AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. SUBMITTED SAME
 SHEETS AGAIN.
  
 B) COVER PAGE IS MISSING THE INFORMATION OF THE DESIGN
 PROFESSIONAL OF RECORD. FAC SEC. 61G15-31.003.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. SUBMITTED SAME
 SHEETS AGAIN.
  
 C) NEED THE TITLE BLOCK OF THE TRUSS ENGINEER ON EACH
 DRAWING AS REQUIRED BY FAC SEC. 61G15-31.003.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. SUBMITTED SAME
 SHEETS AGAIN.
  
 D) DESIGN PROFESSIONAL OF RECORD TO REVIEW AND APPROVE
 ALL TRUSS DRAWINGS AS REQUIRED BY FAC SEC.
 61G15-31.003.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. SUBMITTED SAME
 SHEETS AGAIN.
  
 6- NEW COMMENT: CLARIFY WHAT IS THE PURPOSE OF
 SUBMITTING LETTER FOR "EQUIVALENCE OF PUBLISHED
 VERSIONS OF ASTM D1761 AND ASTM D7147."?
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS..
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-12-20 Cont ID  
Sent By jgomez Date 2016-12-19 Time 15:11 Rev Time 0.00
Received By jgomez Date 2016-12-19 Time 11:34 Sent To  
Notes
2016-12-19 15:14:32RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
 NOTE: THIS MAY BE DONE LATER AT TIME OF ISSUING THE
 PERMIT.
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 3- PROVIDE COMPLETE GABLE END DETAIL AND SPECIFICATIONS
 SHOWING COMPLIANCE WITH SEC. R609.4 FBC-RESIDENTIAL.
  
 4- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR NEW
 CRICKET. IT LOOKS LIKE IS A BIG CRICKET. ROOF PLAN TO
 SHOW THE CRICKET LOCATION. NEED COMPLETE DETAIL SHOWING
 FRAMING MEMBERS AND FASTENERS SHOWING COMPLIANCE WITH
 SEC. R301.1 FBC-RESIDENTIAL.
  
 5- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS AS
 REQUIRED BY SEC. R315 FBC-RESIDENTIAL.
  
 6- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS
 REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. IF
 SPECIFYING SCREWS, THEN SPECIFY SIZE AND NUMBER OF
 SCREWS. IF SPECIFYING ADHESIVE, THEN PROVIDE PRODUCT
 APPROVAL FOR THE ADHESIVE.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) SLIDING GLASS WINDOWS AS SHOWN ON PLANS.
  
 B) WINDOWS AS SHOWN ON PLANS
  
 C) PRECAST LINTELS AS SHOWN ON PLANS.
  
 D) SIMPSON STRUCTURAL CONNECTORS AS SPECIFIED ON PLANS.
 NOTE: FLORIDA PRODUCT APPROVAL "F25" SPECIFIED ON SHEET
 03 IS NOT A VALID FLORIDA PRODUCT APPROVAL NUMBER.
 REVISE AS REQUIRED. ALSO, FLORIDA PRODUCT APPROVALS
 LISTED ON SHEET D-1 ARE NO CURRENT. UPDATE TO THE
 CURRENT 2014 CODE.
  
 E) ROOF TILE AS SPECIFIED ON PLANS.
  
 F) PEEL AND STICK ROOF TILE UNDERLAYMENT AS SPECIFIED
 ON PLANS.
  
 G) ROOF TILE ADHESIVE IF SPECIFIED BY THE DESIGNER OF
 RECORD. SEE ROOF TILE PRODUCT APPROVAL FOR LISTED
 ADHESIVES.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ( NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 9- STRUCTURAL NOTES ON SHEET 03:
 A) SPECIFICATIONS ON ROOF NAILING PATTERN DON'T MATCH
 SPECIFICATIONS SHOWN AT THE BOTTOM OF THE TRUSS
 CONNECTOR SCHEDULE ON THE SAME SHEET. REVISE AS
 REQUIRED TO MATCH. NOTE: SEC. R803.2.3.1
 FBC-RESIDENTIAL REQUIRES 8D RING SHANK NAILS. IF USING
 10D NAILS, THEN PROVIDE COMPLETE ENGINEERING SHOWING
 THAT 10D NAILS ARE EQUAL OR BETTER THAN 8D RING SHANK
 NAILS.
  
 B) REVISE STRUCTURAL NOTE #3. THE HIGH RIB METAL LATH
 REQUIRES 1-3/4" MIN. EMBEDMENT INTO THE WOOD MEMBER.
 REVISE THE SIZE OF NAIL SPECIFIED. 1-1/2" NAILS DON'T
 PROVIDE THE REQUIRED EMBEDMENT. ASTM C1063.
  
 10- TRUSS PACKAGE SUBMITTED:
 A) ENGINEER TO PROVIDE ORIGINAL SIGNATURE (NOT COPY) AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTE.
  
 B) COVER PAGE IS MISSING THE INFORMATION OF THE DESIGN
 PROFESSIONAL OF RECORD. FAC SEC. 61G15-31.003.
  
 C) NEED THE TITLE BLOCK OF THE TRUSS ENGINEER ON EACH
 DRAWING AS REQUIRED BY FAC SEC. 61G15-31.003.
  
 D) DESIGN PROFESSIONAL OF RECORD TO REVIEW AND APPROVE
 ALL TRUSS DRAWINGS AS REQUIRED BY FAC SEC.
 61G15-31.003.
 NOTE: CHECK PROFILE OF TRUSSES AT BOTH ENDS. THEY DON'T
 MATCH PROFILES SHOWN ON PLANS.
  
 11- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS REVISED TO $35,000. THE
 PERMIT FEE BALANCE IS $315.52.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS..
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-02-07 Cont ID  
Sent By rlecky Date 2017-02-07 Time 12:16 Rev Time 0.00
Received By rlecky Date 2017-02-07 Time 12:06 Sent To  
Notes
2017-02-02 11:20:42NEW DRAWING SUBMITTED. NEED RE-STAMP. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-12-15 Cont ID  
Sent By rlecky Date 2016-12-15 Time 09:43 Rev Time 0.00
Received By rlecky Date 2016-12-15 Time 08:52 Sent To  
Notes
2016-12-15 09:44:44THIS PLAN HAS BEEN RELEASED FOR CONSTRUCTION UNDER THE
 FOLLOWING PROVISO:
  
 PROVISO:
  
 SECTION R315 CARBON MONOXIDE ALARMS
  
 R315.1 CARBON MONOXIDE PROTECTION.
 EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING
 BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS
 ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR
 APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER
 FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE
 AS BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL
 CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET (3048
 MM) OF EACH ROOM USED FOR SLEEPING PURPOSES.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-02-08 Cont ID  
Sent By jgomez Date 2017-02-08 Time 18:54 Rev Time 0.00
Received By jgomez Date 2017-02-07 Time 16:35 Sent To  
Notes
2017-02-08 16:36:03CONTRACTOR SUBMITTED ENERGY CALCULATIONS AND PLANS WITH
 IMPACT FEES STAMP. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-08 Cont ID  
Sent By jgomez Date 2017-02-07 Time 16:34 Rev Time 0.00
Received By jgomez Date 2017-01-24 Time 11:16 Sent To  
Notes
2017-01-31 11:16:20R17

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-12-20 Cont ID  
Sent By jgomez Date 2016-12-20 Time 10:09 Rev Time 0.00
Received By jgomez Date 2016-11-22 Time 08:19 Sent To  
Notes
2016-11-23 08:20:07R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2017-02-08 Cont ID  
Sent By jgomez Date 2017-02-08 Time 18:51 Rev Time 0.00
Received By jgomez Date 2017-02-08 Time 18:51 Sent To  
Notes
2017-02-08 18:54:08$236.59 PAID. MU-2017-72.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-02-02 Cont ID  
Sent By jgomez Date 2017-02-02 Time 11:15 Rev Time 0.00
Received By jgomez Date 2017-02-02 Time 11:15 Sent To  
Notes
2017-02-02 11:15:591- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
 NOTE: THIS MAY BE DONE LATER AT TIME OF ISSUING THE
 PERMIT.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-12-19 Cont ID  
Sent By jgomez Date 2016-12-19 Time 15:14 Rev Time 0.00
Received By jgomez Date 2016-12-19 Time 15:14 Sent To  
Notes
2016-12-19 15:14:531- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
 NOTE: THIS MAY BE DONE LATER AT TIME OF ISSUING THE
 PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-02-08 Cont ID  
Sent By jgomez Date 2017-02-08 Time 18:27 Rev Time 0.00
Received By jgomez Date 2017-02-08 Time 18:27 Sent To  
Notes
2017-02-08 18:31:34MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 1- THERE IS NOT INFORMATION IF THE EXISTING A/C UNIT IS
 ADEQUATE TO TAKE THE ADDITIONAL LOAD OR IF NEW A/C WILL
 BE REQUIRED. IF EQUIPMENT NEEDS TO BE REPLACED, THEN
 PROVIDE COMPLETE EQUIPMENT INFORMATION ON THE EQUIPMENT
 SIZING CALCULATIONS AND PLANS. SEC. 107.3.5.3(10). CITY
 AMENDMENTS AND SEC. R403.6.1 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-02-02 Cont ID  
Sent By jgomez Date 2017-02-02 Time 11:21 Rev Time 0.00
Received By jgomez Date 2017-02-02 Time 11:21 Sent To  
Notes
2017-02-02 11:36:00RESIDENTIAL (R3) ADDITION, SECOND MECHANICAL REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- REVISE EQUIPMENT SIZING CALCULATIONS SUBMITTED.
 ACCORDING TO PLANS (SHEET 01) THE EXISTING LIVING AREA
 IS 1945 S.F. AND THE LIVING ROOM EXTENSION IS 351 S.F.
 THEREFORE, THE TOTAL AREA IS 2296 S.F. NOT 1967 S.F..
 REVISE AS REQUIRED. SEC. R403.6.1 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 2- THERE IS NOT INFORMATION IF THE EXISTING A/C UNIT IS
 ADEQUATE TO TAKE THE ADDITIONAL LOAD OR IF NEW A/C WILL
 BE REQUIRED. IF EQUIPMENT NEEDS TO BE REPLACED, THEN
 PROVIDE COMPLETE EQUIPMENT INFORMATION ON THE EQUIPMENT
 SIZING CALCULATIONS AND PLANS. SEC. 107.3.5.3(10). CITY
 AMENDMENTS AND SEC. R403.6.1 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS..
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-12-20 Cont ID  
Sent By jgomez Date 2016-12-20 Time 10:01 Rev Time 0.00
Received By jgomez Date 2016-12-20 Time 07:48 Sent To  
Notes
2016-12-20 10:06:42RESIDENTIAL (R3) ADDITION, MECHANICAL REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS TO
 VERIFY THAT EXISTING A/C UNIT IS ADEQUATE FOR THE
 ADDITIONAL LOAD. SEC. R403.6.1 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
 NOTE: IF EQUIPMENT NEEDS TO BE REPLACED, THEN PROVIDE
 COMPLETE EQUIPMENT INFORMATION ON THE EQUIPMENT SIZING
 CALCULATIONS AND PLANS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS..
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-02-02 Cont ID  
Sent By jgomez Date 2017-02-02 Time 11:16 Rev Time 0.00
Received By jgomez Date 2017-02-02 Time 11:16 Sent To  
Notes
2017-02-02 11:18:26SUBMITTED PRODUCT APPROVALS:
 A) BORAL TILESEAL UNDERLAYMENT NOA 12-0417.06.
  
 B) ENTEGRA ROOF TILE NOA 16-0112.06.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2016-12-20 Cont ID  
Sent By jgomez Date 2016-12-20 Time 10:44 Rev Time 0.00
Received By jgomez Date 2016-12-20 Time 10:44 Sent To  
Notes
2016-12-20 10:45:551- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) ROOF TILE AS SPECIFIED ON PLANS.
  
 B) PEEL AND STICK ROOF TILE UNDERLAYMENT AS SPECIFIED
 ON PLANS.
  
 C) ROOF TILE ADHESIVE IF SPECIFIED BY THE DESIGNER OF
 RECORD. SEE ROOF TILE PRODUCT APPROVAL FOR LISTED
 ADHESIVES.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ( NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.

Review Stop Z ZONING
Rev No 3 Status P Date 2017-02-07 Cont ID  
Sent By njwira Date 2017-02-07 Time 15:23 Rev Time 0.00
Received By njwira Date 2017-02-07 Time 15:23 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2017-02-03 Cont ID  
Sent By njwira Date 2017-02-03 Time 15:00 Rev Time 0.00
Received By njwira Date 2017-02-03 Time 15:00 Sent To  
Notes
2017-02-03 15:02:272/3/17- FAILED
  
 BEAR LAKES
  
 FAILED
 1. MISSING ELEVATION DRAWING FROM PREVIOUS SUBMITTAL
  
 PASSED
  
 REAR SETBACK 41F.T MEETING 25FT. REQUIREMENT
 SIDE SETBACK IS 13FT. MEETING 10FT. REQUIREMENT
 NO TREES BEING MOVED
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-12-01 Cont ID  
Sent By njwira Date 2016-12-01 Time 10:32 Rev Time 0.00
Received By njwira Date 2016-11-30 Time 13:26 Sent To  
Notes
2016-12-01 10:33:3312/1/16- FAILED
  
 DID NOT PROVIDE TWO COPIES OF A SURVEY SHOWING THAT THE
 BUILDING MEETS SETBACK REQUIREMENTS
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  