| Plan Review Stops For Permit 16110989 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-02-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-02-02 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-02-02 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-01-06 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-01-06 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2017-01-06 08:21:50 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. COMMENTS FROM 1ST REVIEW NOT ADDRESSED. | | | 2. PROVIDE FLOOR PLAN TO IDENTIFY ADJOING ROOMS TO | | | PROPOSED SUN ROOM. CANNOT VERIFY EGRESS. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-12-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-12-07 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-12-07 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2016-12-07 09:09:48 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | 1. PROVIDE FLOOR PLAN IDENTIFYING EACH ADJOINING ROOM | | | TO THE PROPOSED SUN ROOM. CANNOT VERIFY EGRESS. | | | 2. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE | | | THEIR PRINTED NAME AND SIGNATURE ON THE PLAN PER FBC | | | 107. | | | | | | R301.2.1.1.2.2 | | | FOR THE PURPOSE OF APPLYING THE CRITERIA OF THE | | | AAMA/NPEA/NSA 2100, SUNROOMS SHALL BE CATEGORIZED IN | | | ONE OF THE FOLLOWING CATEGORIES BY THE PERMIT | | | APPLICANT, DESIGN PROFESSIONAL OR THE PROPERTY OWNER | | | WHERE THE SUNROOM IS BEING CONSTRUCTED. | | | | | | CATEGORY II: A THERMALLY ISOLATED SUNROOM WITH ENCLOSED | | | WALLS. THE OPENINGS ARE PERMITTED TO BE ENCLOSED WITH | | | TRANSLUCENT OR TRANSPARENT PLASTIC OR GLASS. THE SPACE | | | IS DEFINED AS A NONHABITABLE, NONCONDITIONED SUNROOM. | | | | | | R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2017-01-04 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-04 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-04 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-12-02 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-12-02 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-12-02 |
Time |
08:50 |
Sent To |
B |
|
| Notes |
| 2016-12-02 08:50:45 | PLEASE ADDRESS ZONING COMMENTS FOR AN ELECTRICAL | | | APPROVAL | | | | | | VAL PEREZ | | | *6717 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-02-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-02-02 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-01-30 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2017-01-31 11:10:51 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-01-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-01-06 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-12-22 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2016-12-22 15:24:10 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-12-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-12-07 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-11-22 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2016-11-23 09:20:09 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-02-01 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-02-01 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-01-31 |
Time |
14:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-12-30 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-12-30 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-12-28 |
Time |
15:29 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-11-30 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-11-30 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-11-23 |
Time |
14:06 |
Sent To |
E |
|
| Notes |
| 2016-11-30 12:01:37 | 11/30/16- FAILED | | | | | | NEED BUILDING ELEVATION DRAWINGS. | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|