Plan Review Details - Permit 16110914
| Plan Review Stops For Permit 16110914 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-12-14 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-12-14 |
Time |
08:33 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-12-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-12-06 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-12-06 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2016-12-06 09:41:34 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | 1. PROVIDE SITE PLAN WITH SETBACKS OF NEW BUILDING. | | | | | | 3. ALL PLANS AND DOCUMENTS SHALL BE SUBMITTED IN | | | DUPLICATE. | | | | | | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | THE CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY | | | CHAPTER 471, FLORIDA STATUTES& 61G15 FLORIDA | | | ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA STATUTES& | | | 61G1 FLORIDA ADMINISTRATIVE CODE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-12-19 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-12-19 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2016-12-19 13:07:48 | NO ELECTRICAL WITHIN THIS SCOPE OF WORK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-12-05 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-12-05 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-12-05 |
Time |
18:08 |
Sent To |
B |
|
| Notes |
| 2016-12-05 18:18:55 | 1ST REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1] PLEASE PROVIDE ELECTRICAL PLANS WITH ALL ELECTRICAL | | | OUTLETS SHOWN, DOCUMENTS MUST BE SUBMITTED IN SETS OF 2 | | | OR MORE PER APPLICATION . FBC 107 | | | | | | 2] SHOW GFCI PROTECTION FOR GARAGE RECEPTACLES PER NEC | | | 210.8(A)(2). | | | | | | 3] IF MORE THAN A SINGLE BRANCH OR MULTI-BRANCH CIRCUIT | | | IS BEING SUPPLIED FOR POWER A GROUNDING ELECTRODE | | | SYSTEM SHALL BE INSTALLED AND CONNECTED TO THE | | | EQUIPMENT GROUNDING CONDUCTOR. NEC 250.32 (SEPERATE | | | STRUCTURE) | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-12-19 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-12-09 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2016-12-12 11:31:54 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-12-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-12-06 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-11-21 |
Time |
14:33 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-12-13 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-12-12 |
Time |
16:24 |
Sent To |
B |
|
| Notes |
| 2016-12-13 16:00:56 | 12/13/16- PASSED | | | | | | NO TREES CAN BE MOVED WITHOUT A TREE ALTERATION PERMIT. | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-11-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-12-06 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-11-22 |
Time |
13:55 |
Sent To |
E |
|
| Notes |
| 2016-12-06 10:25:15 | CHECK E-MAIL | | 2016-11-23 15:24:46 | 11/23/16- FAILED | | | | | | 1. PLEASE PROVIDE TWO(2)COPIES OF A SURVEY SHOWING | | | WHERE THE ACCESSORY STRUCTURE IS GOING. | | | 2. PLEASE PROVIDE MEASUREMENTS ON HOW BIG THE GARAGE | | | WILL BE | | | | | | PASSED | | | 1. ONE STORY DOES NOT EXCEED THE 25FT. HEIGHT LIMIT | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|
|