| Plan Review Stops For Permit 16110325 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-02-13 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-02-08 |
Time |
19:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-12 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-12 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2016-12-12 18:59:54 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ON SHEET 2, GENERAL NOTE 6 SPECIFIES CITRUS COUNTY | | | AMMENDMENTS. THIS SHOULD BE CITY OF WEST PALM BEACH | | | AMENDMENTS. FBC 107.2.1 | | | | | | 2) ALSO ON SHEET 2, UNDER SOIL, NOTE 1 IS NOT LEGIBLE. | | | I BELIEVE IT SHOULD STATE 95 PERCENT DENSITY. FBC | | | 107.2.1 | | | | | | 3) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED. | | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | | RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE | | | SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE | | | ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL | | | HAVE A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM | | | AND 1/4 INCH (6.4 MM) MAXIMUM. VENTILATION OPENINGS | | | HAVING A LEAST DIMENSION LARGER THAN 1/4 INCH (6.4 MM) | | | SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH | | | SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH | | | OPENINGS HAVING A LEAST DIMENSION OF 1/16 INCH (1.6 MM) | | | MINIMUM AND 1/4 INCH (6.4 MM) MAXIMUM. OPENINGS IN ROOF | | | FRAMING MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF | | | SECTION R802.1.8. REQUIRED VENTILATION OPENINGS SHALL | | | OPEN DIRECTLY TO THE OUTSIDE AIR. | | | R806.2 MINIMUM VENT AREA. THE MINIMUM NET FREE | | | VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE | | | VENTED SPACE. | | | | | | 4) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR | | | R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY COMPLIANCE | | | FORMS AS REQUIRED. | | | | | | 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE ASPHALT ROOF SHINGLES, MODIFIED BITUMEN ROOFING | | | MATERIAL (WITH ENHANCED FASTENING CALCULATIONS), | | | CASEMENT WINDOWS, STRUCTURAL MULLIONS AND THE GABLE | | | LOUVER VENT. | | | | | | 6) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-01-31 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-01-31 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-11-15 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2016-11-15 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2016-11-15 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2016-11-15 12:10:48 | 16110325 | | | 288 FLAMINGO DRIVE | | | SF REMODEL | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | | | | PROVIDE THE LOCATION OF THE PANEL BOARD. INCLUDE A | | | PANEL SCHEDULE SHOWING THE NEW CIRCUITS WITH | | | APPROPRIATE OVERCURRENT PROTECTION. NEC 230.70, FBC R | | | E3405.1 | | | | | | VERIFY ALL NEW RECEPTACLES ARE TAMPER RESISTANT. NEC | | | 406.2; FBC R E4002.14 | | | | | | VERIFY ALL NEW CIRCUITS ARE AFCI PROTECTED. NEC 210.12; | | | FBC R E3902.12 | | | | | | CEILING ELECTRICAL BOXES IF INTENDED FOR SUPPORT OF | | | PADDLE FANS MUST BE LISTED FOR THAT USE. NEC 422.18; | | | FBC R 3905.9 | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | | OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS | | | APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON | | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | | ROOM USED FOR SLEEPING. 2014 FBC R314, 315 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6654(OFFICE) | | | 561-373-3701(CELL) | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-02-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-02-08 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-02-08 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-02-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-02-06 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-02-06 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2017-02-06 13:48:17 | COA SUBMITTED BY ROB WITH TDGONE HOWEVER, REVISIONS | | | FROM COA NOT REFLECTED IN PERMITTED SET. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-11-21 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-11-21 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-11-21 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2016-11-21 15:11:14 | REQUIRES SUBMITTAL OF COA. FHM SPOKE TO CAREY THE | | | CONTRACTOR, SENT FORM AND EXPLAINED PROCESS. QUESTIONS | | | CONTACT FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION | | | PLANNER AT 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-02-13 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-26 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-12 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-11-08 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2017-02-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-02-21 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-02-21 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2017-02-21 11:03:56 | MU-2017-4373 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-12 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-12 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2016-12-12 15:54:11 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-12 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-12 |
Time |
18:24 |
Sent To |
|
|
| Notes |
| 2016-12-12 18:26:29 | NO MECHANICAL WORK IS SHOWN ON THE PLANS. A SEPARATE | | | PERMIT, APPLICATION AND REVIEW OF PLANS IS REQUIRED FOR | | | MECHANICAL WORK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-30 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-30 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-02-10 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-02-10 |
Time |
18:55 |
Sent To |
|
|
| Notes |
| 2017-02-10 18:59:50 | GAF ASPHALT SHINGLES FL10124-R10124-R19 | | | POLYGLASS MODIFIED BITUMEN FL1654-R19, SYSTEM W-141 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-12 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-12 |
Time |
19:00 |
Sent To |
|
|
| Notes |
| 2016-12-12 19:00:40 | NO ROOFING PRODUCT APPROVALS WERE SUBMITTED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-21 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-11-21 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-11-21 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|