| Plan Review Stops For Permit 16110180 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-02-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-02-15 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-02-15 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-01-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-01-26 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-01-26 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2017-01-26 17:58:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | TWO COMMENTS REMAINING FROM PREVIOUS LIST (NOTE THAT A | | | PROVISO WILL BE CONSIDERED; CONTACT S.KENNEDY IF I AM | | | UNAVAILABLE): | | | | | | 3. INCORRECT OCCUPANT LOAD FOR MERCANTILE, SEE FBC B | | | TABLE 1004.1.2. | | | | | | THIS WAS CHANGED FROM 100 TO 60. SEE THE TABLE - GRADE | | | FLOOR REQUIRES 30 SF PER PERSON. REVISE PLAN | | | ACCORDINGLY. | | | | | | 14. OFFICE DOOR LACKS MANEUVERING CLEARANCE, PULL SIDE, | | | FBC ACCESSIBILITY 404.2.4.1. | | | | | | THIS WAS ADDRESSED BY SHOWING CLEAR FLOOR SPACE ON THE | | | OPPOSITE SIDE. PLEASE REFER TO DIAGRAMS, 18" PULL SIDE | | | REQUIRED, REVISE PLAN ACCORDINGLY. | | | | | | THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING PROVISOS: | | | | | | A. FBC 1006.1, MEANS OF EGRESS ILLUMINATION IS REQUIRED | | | IN THE EXIT DISCHARGE; TO BE VERIFIED AT INSPECTION. | | | | | | B. PRODUCT APPROVALS TO BE SUBMITTED AS A REVISION | | | PRIOR TO INSTALLATION | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-01-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-01-04 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-01-04 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2017-01-04 18:00:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | FROM PREVIOUS LIST: | | | | | | 1. THIS APPEARS TO BE A CHANGE OF OCCUPANCY. REVISE | | | PLAN TO SHOW COMPLIANCE WITH FBC EXISTING | | | BUILDING CHAPTER 10. | | | | | | 2ND REVIEW, PLAN REVISED TO STATE THAT THE PREVIOUS | | | OCCUPANCY WAS "INDUSTRIAL". SEE FBC B CHAPTER | | | 10 AND REVISE PLAN TO DECLARE AN OCCUPANCY FROM THE | | | BUILDING CODE FOR . DO YOU MEAN FACTORY | | | INDUSTRIAL (F)? F1 OR F2? | | | | | | REVISE PLAN TO SHOW COMPLIANCE WITH FBC EB CHAPTER 10. | | | NO INFORMATION PROVIDED. IT APPEARS THAT | | | YOU PROPOSE TO GO TO A HIGHER RISK IN SOME OR ALL OF | | | THE TABLES. WHILE I AM ABLE TO DETERMINE | | | COMPLIANCE IN SOME INSTANCES, NO SURVEY WAS PROVIDED SO | | | COMPLIANCE WITH FBC EB TABLE 1012.6 CANNOT | | | BE DETERMINED. WITHOUT A SURVEY AND OCCUPANCY | | | CLASSIFICATION, COMPLIANCE CANNOT BE DETERMINED. | | | | | | 2. SEE COMMENT 3. | | | | | | 3. OCCUPANT LOAD WAS PROVIDED USING 100 SF PER PERSON, | | | BUT IT APPEARS THAT A PORTION OF THIS AREA | | | SHOULD USE MERCANTILE, SEE FBC TABLE 1004.1.2. | | | | | | 2ND REVIEW, INCORRECT OCCUPANT LOAD FOR MERCANTILE, SEE | | | FBC B TABLE 1004.1.2. | | | | | | 3. 2ND REVIEW, REVISE PLAN TO CLARIFY: | | | | | | BUILDING CLASSIFICATION IIIB; CLARIFY | | | | | | 2ND REVIEW, DO YOU MEAN CONSTRUCTION TYPE? REVISE PLAN | | | TO TERMINOLOGY CONSISTENT WITH THE BUILDING | | | CODE OR PROVIDE CLARIFICATION. | | | | | | 4. FBC 1006.1, MEANS OF EGRESS ILLUMINATION IS REQUIRED | | | IN THE EXIT DISCHARGE. NO LIGHTING IS SHOWN | | | IN THE OUTDOOR AREA WHICH IS A PART OF THE EXIT | | | DISCHARGE. | | | | | | 2ND REVIEW, RESPONSE LETTER STATES TO SEE A2. THIS IS | | | THE DEMO PAGE. SHEET E2 HAS SOME LIGHTING | | | ADDED BUT NOT IN ALL OUTDOOR AREAS. | | | | | | 5. FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | | FOR COMPONENTS AND CLADDING, FBC 1609. | | | | | | 2ND REVIEW, DRAWING SHEETS ARE ILLEGIBLE. LOOSE SHEETS | | | WERE ALSO PROVIDED. IT APPEARS THAT THE | | | NOAS WERE NOT PROPERLY BOUND. ONLY ONE PRODUCT APPROVAL | | | WAS PROVIDED (GLAZED DOOR). ANY PRODUCT | | | APPROVALS NOT SUBMITTED PRIOR TO PERMIT ISSUANCE WILL | | | BE REQUIRED TO BE SUBMITTED AS A REVISION, | | | WITH FEES. | | | | | | 6. FBC 1011.1, THE EXIT DISCHARGE WHICH GOES THROUGH | | | THE OUTDOOR FENCED PLAY AREAS IS NOT READILY | | | APPARENT. IT APPEARS THAT EXIT SIGNS ARE REQUIRED IN | | | THIS AREA, REVISE PLAN. | | | | | | 2ND REVIEW, NOT ADDRESSED. PLAY AREAS 1, 2, 3 DO NOT | | | PROVIDE A CLEAR PATH TO EXIT. IF THE | | | OCCUPANT LEAVES THE BUILDING AND TURNS LEFT, THEY DEAD | | | END. IF THEY TAKE GATE INTO PLAY AREA 3, | | | THEY ARE ALSO REQUIRED TO BACKTRACK. IT IS NOT CLEAR | | | HOW AN OCCUPANT SHOULD KNOW THAT THEY NEED TO | | | EGRESS THROUGH DOG PLAY AREAS 1 OR 2 TO GET TO THE | | | PUBLIC WAY. A CLEAR PATH TO THE PUBLIC WAY IS | | | NOT PROVIDED, REVISE. | | | | | | EXPLAIN RATIONALE OF FORCING OCCUPANTS TO TRAVEL | | | THROUGH ANIMAL AREAS TO EXIT. IT APPEARS THAT A | | | SAFER MEANS OF EGRESS SHOULD BE PROVIDED. | | | | | | 7. REVISE PLAN TO SHOW EXIT DISCHARGE (PATH OF EXIT TO | | | THE PUBLIC WAY), FOR THE REAR EXIT, | | | INCLUDING THE MEANS OF EGRESS ILLUMINATION FBC 1008. | | | | | | 2ND REVIEW, NOT ADDRESSED. | | | | | | 8. OK | | | | | | 9-10. OK | | | | | | 11. PROVIDE A DETAIL FOR THE CHECK OUT COUNTER, FBC | | | ACCESSIBILITY 904. | | | | | | 2ND REVIEW, THE DETAIL SHOWS THE COUNTER TOP AT 3', A | | | SECOND COUNTER AT 3'6. SEE FBC A 904. | | | | | | 12. REVISE PLAN TO SHOW COMPLIANCE WITH ACCESSIBLE | | | ROUTE, FBC ACCESSIBILITY 202.4, 206.2. | | | INFORMATION REGARDING THE ENTRY DOOR AND PARKING | | | LOCATION WAS NOT PROVIDED; DOES THE ROUTE COMPLY | | | WITH FBC A 303? | | | | | | 13. SEE IMPACT FEE REVIEW. | | | | | | NEW COMMENT: | | | | | | 14. OFFICE DOOR LACKS MANEUVERING CLEARANCE, PULL SIDE, | | | FBC ACCESSIBILITY 404.2.4.1. | | | | | | 15. PLAN PAGES ARE NUMBERED | | | | | | CVR OF 10 | | | A-0 OF 9 | | | ETC | | | | | | IT IS NOT CLEAR WHETHER THERE SHOULD BE 9 OR 10 PAGES. | | | REVISE TO BE CONSISTENT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-11-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-29 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-29 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2016-11-29 12:43:25 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. THIS APPEARS TO BE A CHANGE OF OCCUPANCY. REVISE | | | PLAN TO SHOW COMPLIANCE WITH FBC EXISTING BUILDING | | | CHAPTER 10. | | | | | | 2. OCCUPANT LOAD FOR A SMALL PORTION OF THE BUILDING | | | HAS BEEN DETERMINED. PROVIDE OCCUPANT LOAD FOR THE | | | REMAINDER OF THE BUILDING (6,885 SF). SEE FBC 1004.1.2, | | | PROPOSE AN OCCUPANT LOAD WHICH MOST CLOSELY RESEMBLES | | | THE USE OF THE SPACE. | | | | | | 3. OCCUPANT LOAD WAS PROVIDED USING 100 SF PER PERSON, | | | BUT IT APPEARS THAT A PORTION OF THIS AREA SHOULD USE | | | MERCANTILE, SEE FBC TABLE 1004.1.2. | | | | | | 3. REVISE PLAN TO CLARIFY: | | | IN THE TABLE ASCE7 10: | | | OCCUPANCY TYPE IIIB, CLARIFY | | | BUILDING CLASSIFICATION IIIB; CLARIFY | | | | | | TYPE OF CONSTRUCTION; SEE FBC CHAPTER 6. PLAN STATES | | | UNPROTECTED (NOT SPRNKLERED). THIS IS NOT A BUILDING | | | TYPE. | | | | | | 4. FBC 1006.1, MEANS OF EGRESS ILLUMINATION IS REQUIRED | | | IN THE EXIT DISCHARGE. NO LIGHTING IS SHOWN IN THE | | | OUTDOOR AREA WHICH IS A PART OF THE EXIT DISCHARGE. | | | | | | 5. FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | | FOR COMPONENTS AND CLADDING, FBC 1609. | | | | | | 6. FBC 1011.1, THE EXIT DISCHARGE WHICH GOES THROUGH | | | THE OUTDOOR FENCED PLAY AREAS IS NOT READILY APPARENT. | | | IT APPEARS THAT EXIT SIGNS ARE REQUIRED IN THIS AREA, | | | REVISE PLAN. | | | | | | 7. REVISE PLAN TO SHOW EXIT DISCHARGE (PATH OF EXIT TO | | | THE PUBLIC WAY), FOR THE REAR EXIT, INCLUDING THE MEANS | | | OF EGRESS ILLUMINATION FBC 1008. | | | | | | 8. A2 HAS CONFLICATING NOTES REGARDING DOOR HARDWARE. | | | ONE STATES THAT DOORS SHOULD HAVE PANIC DEVICES, | | | ANOTHER SPECS LEVERS, FBC 107. | | | | | | 9. SEE PLUMBING COMMENTS REGARDING ACCESSIBLITY; ALL | | | ARE APPLICABLE FOR BUILDING REVIEW. | | | | | | 10. A4 HAS A FIRE ALARM LEGEND, FIRE ALARM FIXTURES NOT | | | SHOWN, FBC 107. | | | | | | 11. PROVIDE A DETAIL FOR THE CHECK OUT COUNTER, FBC | | | ACCESSIBILITY 904. | | | | | | 12. REVISE PLAN TO SHOW COMPLIANCE WITH ACCESSIBLE | | | ROUTE, FBC ACCESSIBILITY 202.4, 206.2. INFORMATION | | | REGARDING THE ENTRY DOOR AND PARKING LOCATION WAS NOT | | | PROVIDED; DOES THE ROUTE COMPLY WITH FBC A 303? | | | | | | 13. SEE IMPACT FEE REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2017-04-05 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-04-05 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-04-05 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2017-03-06 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-06 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-06 |
Time |
09:19 |
Sent To |
Z |
|
| Notes |
| 2017-03-06 09:19:55 | ADDRESS MECHANICAL COMMENTS FOR AN ELECTRICAL APPROVAL | | | | | | V PEREZ | | | *6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2017-02-27 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-02-27 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-02-27 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2017-02-27 13:30:59 | ADDRESS MECHANICAL COMMENTS FOR AN ELECTRICAL APPROVAL | | | | | | V PEREZ | | | *6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-01-26 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-26 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-26 |
Time |
06:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-01-06 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-06 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-06 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2017-01-06 09:52:52 | 2ND ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS NOT ADDRESSED FROM INITIAL REVIEW: | | | | | | 5. SHOW CIRCUIT DESIGNATION FOR ALL NEW LIGHTING AND | | | POWER OUTLETS AND EQUIPMENT. SHOW WHAT PANEL THEY | | | ORIGINATE FROM TO VERIFY LOAD CALCULATION DO NOT | | | EXCEEDED AMPS PER SIZE OF MAINS. | | | 6. SHOW DESIGN COMPLIANCE PER FBC ENERGY CONSERVATION | | | CODE. A GENERAL NOTE WILL NOT SUFFICE, SHOW SYMBOLS OF | | | AUTOMATIC CONTROL LIGHTING AND LIGHTING DENSITIES FOR | | | AREAS. | | | | | | 11. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL | | | FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS | | | REGARDING THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-11-12 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-11-12 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-11-12 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2016-11-12 16:21:01 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | 1. PLEASE PROVIDE AN ACCURATE ONE-LINE RISER THAT | | | EXISTING AS CONDUCTORS SIZE AT 1/0 IS UNDERSIZED FOR A | | | 200A MAIN. FBC 107.3.5 | | | 2. DELETE RESIDENTIAL CODE NOTES FROM THE ELECTRICAL | | | NOTES, ONLY PROVIDE WHAT IS APPLICABLE FOR THIS | | | PROJECT. FBC 107.3.5 | | | 3. CLARIFY HEX NOTES TO FLOOR PLAN. NOT SHOWN. | | | 4. SHOW A COMPLETE PANEL BOARD SCHEDULE NOT JUST | | | ADDITIONAL AS SHOWN. THERE ARE NEW POWER AND LIGHTING | | | OUTLETS SHOWN. NEW EXHAUST FANS, NEW A/H AND A/C MUST | | | BE ACCOUNTED FOR. | | | 5. SHOW CIRCUIT DESIGNATION FOR ALL NEW LIGHTING AND | | | POWER OUTLETS AND EQUIPMENT. SHOW WHAT PANEL THEY | | | ORIGINATE FROM TO VERIFY LOAD CALCULATION DO NOT | | | EXCEEDED AMPS PER SIZE OF MAINS. | | | 6. SHOW DESIGN COMPLIANCE PER FBC ENERGY CONSERVATION | | | CODE. A GENERAL NOTE WILL NOT SUFFICE, SHOW SYMBOLS OF | | | AUTOMATIC CONTROL LIGHTING AND LIGHTING DENSITIES FOR | | | AREAS. | | | 7. NEW A/C EQUIPMENT MUST PROVIDE A W/P GFCI RECEPTACLE | | | WITHIN 25FT OF UNIT FOR SERVICE. NEC 210.63. SHOW A | | | DISCONNECT FOR A/C UNIT AND A/H UNIT INSIDE. | | | 8. LABEL ON FLOOR PLAN WHAT IS NEW OR EXISTING FOR A | | | COMPLETE REVIEW. | | | 9. EM LIGHTING TO BE PROVIDED TO NEW BATHROOM AREA. | | | 10. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM | | | TO INDICATE NEC 110.24- AVAILABLE FAULT CURRENT- FIELD | | | MARKINGS; SEE VERBIAGE IN CODE. | | | 11. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL | | | FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS | | | REGARDING THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2016-11-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-29 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-29 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2016-11-29 17:09:32 | CONFIRMED W/MG THAT REVIEW IS NOT REQUIRED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2017-02-24 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2017-02-24 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2017-02-24 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-01-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-01-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-01-19 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2017-01-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-01-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-12-30 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2016-12-30 10:32:48 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) PREVIOUS COMMNET 1) - NOT COMPLIED - SHEET A 4 - | | | EXIT SIGNS ARE INDICATED AT DOORS LEADING TO THE | | | OUTSIDE PLAY AREA; HOWEVER, THERE ARE SEVERAL GATES AND | | | PLAY AREAS THAT MUST BE NAVIGATED UNTIL THE EXIT | | | DISCHAGE IS REACHED. THE EXIT IS NOT REACHED UNTIL THE | | | POINT OF PUBLIC WAY. | | | | | | 8.1.2.4* EXIT TRAVEL DISTANCES. | | | 8.1.2.4.1 IN ANIMAL HOUSING FACILITIES NOT SPRINKLERED | | | IN ACCORDANCE WITH SECTION 9.2, EXIT TRAVEL DISTANCE | | | SHALL NOT EXCEED 75 FT (23 M) FROM ANY POINT IN THE | | | FACILITY. | | | | | | 8.1.2.1 NUMBER OF MEANS OF EGRESS. | | | 8.1.2.1.1 TWO MEANS OF EGRESS FOR HUMAN AND ANIMAL | | | OCCUPANTS, AS A MINIMUM, SHALL BE PROVIDED IN EVERY | | | FACILITY, SECTION,AND AREA WHERE SIZE, OCCUPANCY, AND | | | ARRANGEMENT ENDANGER OCCUPANTS ATTEMPTING TO USE A | | | SINGLE MEANS OF EGRESS | | | THAT IS BLOCKED BY FIRE OR SMOKE. | | | 8.1.2.1.2 WHERE TWO MEANS OF EGRESS ARE REQUIRED, THEY | | | SHALL BE ARRANGED TO MINIMIZE THE POSSIBILITY THAT BOTH | | | MIGHT BE RENDERED IMPASSABLE BY THE SAME EMERGENCY | | | CONDITION. | | | | | | 11.2 MEANS OF EGRESS REQUIREMENTS. | | | 11.2.1 GENERAL. EACH REQUIRED MEANS OF EGRESS SHALL BE | | | IN ACCORDANCE WITH THE APPLICABLE PORTIONS OF CHAPTER | | | 8. | | | 11.2.2 MEANS OF EGRESS COMPONENTS. | | | 11.2.2.1 GENERAL. COMPONENTS OF MEANS OF EGRESS SHALL | | | BE LIMITED TO THE TYPES DESCRIBED IN NFPA 101, LIFE | | | SAFETY CODE, CHAPTER 7; OR NFPA 5000, BUILDING | | | CONSTRUCTION AND SAFETY CODE, CHAPTER 11; CHAPTER 8 OF | | | THIS STANDARD; AND AS MODIFIED IN THIS SUBSECTION. | | | | | | NFPA 101, CHAPTER 3, DEFINITIONS. | | | 3.3.81* EXIT. THAT PORTION OF A MEANS OF EGRESS THAT IS | | | SEPARATED FROM ALL OTHER SPACES OF A BUILDING OR | | | STRUCTURE BY CONSTRUCTION OR EQUIPMENT AS REQUIRED TO | | | PROVIDE A PROTECTED WAY OF TRAVEL TO THE EXIT | | | DISCHARGE. | | | | | | 3.3.82 EXIT ACCESS. THAT PORTION OF A MEANS OF EGRESS | | | THAT LEADS TO AN EXIT. | | | 3.3.83 EXIT DISCHARGE. THAT PORTION OF A MEANS OF | | | EGRESS BETWEEN THE TERMINATION OF AN EXIT AND A PUBLIC | | | WAY. | | | | | | 3.3.218 PUBLIC WAY. A STREET, ALLEY, OR OTHER SIMILAR | | | PARCEL OF LAND ESSENTIALLY OPEN TO THE OUTSIDE AIR | | | DEEDED, DEDICATED, OR OTHERWISE PERMANENTLY | | | APPROPRIATED TO THE PUBLIC FOR PUBLIC USE AND HAVING A | | | CLEAR WIDTH AND HEIGHT OF NOT LESS THAN 10 FT (3050 | | | MM). | | | | | | | | | THE PROPOSED TRAVEL DISTANCES INDICATED ON A 4 ARE | | | NONCOMPLIANT AND NOT APPROVED. YOUR PROPOSED EXITS ARE | | | EXIT ACCESSES WITH YOUR EXIT ACTUALLY BEING AT THE END | | | OF YOUR OCUTDOOR PALY AREA. PLEASE CORRECT. | | | | | | | | | 2) PREVIOUS COMMENT 2) - COMPLIED. | | | | | | | | | 3) PREVIOUS COMMENT 3) - COMPLIED. | | | | | | | | | 4) PREVIOUS COMMENT 4) - NOT COMPLIED - SHEET A 4 - | | | THERE IS ONE EXIT INDICATED FROM THE MERCANTILE AREA; | | | HOWEVER, PER NFPA 150, 8.1.2.1 NUMBER OF MEANS OF | | | EGRESS. | | | 8.1.2.1.1 TWO MEANS OF EGRESS FOR HUMAN AND ANIMAL | | | OCCUPANTS, AS A MINIMUM, SHALL BE PROVIDED IN EVERY | | | FACILITY, SECTION, AND AREA WHERE SIZE, OCCUPANCY, AND | | | ARRANGEMENT ENDANGER OCCUPANTS ATTEMPTING TO USE A | | | SINGLE MEANS OF EGRESS | | | THAT IS BLOCKED BY FIRE OR SMOKE. | | | | | | SHOULD A FIRE OCCUR IN THE AREA OF THE GROOMING THE | | | MAIN EXIT COULD BE INACCESSIBLE. A SECOND EXIT SHALL BE | | | IDENTIFIED AND PROVIDED FROM THIS AREA. | | | | | | | | | | | | ADDITIONAL COMMENTS: | | | | | | | | | | | | 5) SHEET A 2 & A 4 - AN EXIT ACCESS IS INDICATED | | | PASSING THROUGH A DOOR LEADING INTO INDOOR INDOOR PLAY | | | AREA # 1 THAT THEN LEADS TO THE EXIT IN THE CORNER. | | | | | | THE DOOR LEADING TO INDOOR PLAY AREA # 1 IS NOT | | | INDICATED ON THE DOOR SCHEDULE AND DOES NOT SHOW | | | COMPLIANT EXIT HARDWARE. | | | | | | PLEASE CORRECT. | | | | | | | | | | | | 6) SHEET A 2 - DOORS INDICATED AS E ARE EXIT DOORS AND | | | ARE NOT SHOWING COMPLIANT EXIT HARDWARE ON THE DOOR | | | SCHEDULE, INCLUDING LOCKING AND LATCHING DEVICES. | | | | | | PLEASE CORRECT. | | | | | | | | | | | | 7) SHEET A 4 - ONE EXIT IS INDICATED FROM THE OVERNIGHT | | | DOG PLAY AREA. | | | | | | 8.1.2.1.1 TWO MEANS OF EGRESS FOR HUMAN AND ANIMAL | | | OCCUPANTS, AS A MINIMUM, SHALL BE PROVIDED IN EVERY | | | FACILITY, SECTION, AND AREA WHERE SIZE, OCCUPANCY, AND | | | ARRANGEMENT ENDANGER OCCUPANTS ATTEMPTING TO USE A | | | SINGLE MEANS OF EGRESS | | | THAT IS BLOCKED BY FIRE OR SMOKE. | | | | | | PLEASE CORRECT. | | | | | | | | | | | | 8) SHEET A 2 & A 4 - EXIT ACCESS IS BEING SHOWN FROM 2 | | | DOORS LEADING TO THE OUTDOOR PLAY AREA AND GATE | | | SYSTEMS. THESE ARE EXIT ACCESS AND NOT EXITS. ONCE INTO | | | THE AREA THERE IS NO INDICATIONS SHOWING THE WAY | | | LEADING TO AN EXIT. HOW WILL SOMEONE KNOW WHERE TO GO | | | ONCE THEY LEAVE THE DOORS. | | | | | | PLEASE PROVIDE CODE COMPLIANT EXIT SIGNAGE. | | | | | | | | | | | | 9) SHEET A 2 & A 4 - THE GATES WITHIN THE OUTDOOR PLAY | | | AREA ARE NOT INDICATED BY DETAIL ON THE DOOR SCHEDULE | | | OR ANY PLAN SHEET. THESE GATES ARE PART OF THE EXIT | | | ACCESS AND SHALL COMPLY WITH CODE. | | | | | | PLEASE PROVIDE THE SEPCIFIC DETAIL REGARDING THE GATES, | | | INCLUDING LOCKING AND LATCHING DEVICES. | | | | | | | | | | | | 10) SHEET E 1 - THERE ARE NO EXIT PATH ILLUMINATION AT | | | THE OUTDOOR AREAS. | | | | | | NFPA 101, CHAPTER 7, MEANS OF EGRESS | | | 7.8 ILLUMINATION OF MEANS OF EGRESS. | | | 7.8.1 GENERAL. | | | 7.8.1.1* ILLUMINATION OF MEANS OF EGRESS SHALL BE | | | PROVIDED IN ACCORDANCE WITH SECTION 7.8 FOR EVERY | | | BUILDING AND STRUCTURE WHERE REQUIRED IN CHAPTERS 11 | | | THROUGH 43. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT | | | ACCESS SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, | | | CORRIDORS, RAMPS, ESCALATORS, AND PASSAGEWAYS LEADING | | | TO AN EXIT. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT | | | DISCHARGE SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, | | | CORRIDORS, RAMPS, ESCALATORS, WALKWAYS, AND EXIT | | | PASSAGEWAYS LEADING TO A PUBLIC WAY. | | | 7.8.1.2 ILLUMINATION OF MEANS OF EGRESS SHALL BE | | | CONTINUOUS DURING THE TIME THAT THE CONDITIONS OF | | | OCCUPANCY REQUIRE THAT THE MEANS OF EGRESS BE AVAILABLE | | | FOR USE, UNLESS OTHERWISE PROVIDED IN 7.8.1.2.2. | | | | | | PLEASE PROVIDE ILLUMINATION AS REQUIRED. | | | | | | | | | | | | 11) SHEET CVR - A BUNESS & MERCANTILE OCCUPANCY CLASS | | | IS INDICATED. ON SHEET A 4 AN ASSEMBLY OCCUPANCY IS | | | INDICATED.FOR THE MEANS OF EGRESS. | | | | | | THIS IS CONFUSING AND SHALL BE EXPLAINED AND/OR | | | CORRECTED. | | | | | | | | | | | | 12) SHEET CVR - UNDER THE SCOPE OF WORK # 2. - FENCE | | | NEW PLAY AREA WITH 6' CHAIN LINK AND WOOD FENCE AS | | | INDICATED ON PLAN. THERE IS NO INDICATION AND/OR DETAIL | | | REGARDING THIS NOTE. | | | | | | PLEASE PROVIDE SPECIFIC DETAIL FOR THIS COMMENT | | | INCLUDING EITHER AT EACH LOCATION. ENSURE THAT | | | CONSIDERATION IS GIVEN TO THE WALL FINISH RATING ALONG | | | THE EXIT PATH OF TRAVEL. | | | | | | | | | | | | 13) THIS COMMENT IS FOR INFORMATIONAL PURPOSES. | | | | | | SHEET A 4 - A FIRE ALARM IS INDICATED WITH 24/7 | | | MONOTORING. PLEASE BE ADVISED THAT MONITORING IS NOT | | | REQURED PER NFPA 105 REQUIRMENTS FOR THE SIZE OF THIS | | | OCCUPANCY | | | | | | CHAPTER 11, CLASS 1 ANIMAL HOUSING FACILITIES | | | | | | 11.3.1 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | | 11.3.1.1 GENERAL. A FIRE ALARM SYSTEM IN ACCORDANCE | | | WITH SECTION 9.3 SHALL BE REQUIRED IN ACCORDANCE WITH | | | THIS SUBSECTION. | | | 11.3.1.1.1 IN ANIMAL HOUSING FACILITIES GREATER THAN | | | 3000 FT2 (280 M2) BUT NO MORE THAN 20,000 FT2 (1860 | | | M2), A LOCAL FIRE ALARM SYSTEM SHALL BE PROVIDED. | | | 11.3.1.1.2 IN ANIMAL HOUSING FACILITIES GREATER THAN | | | 20,000 FT2 (1860 M2), A MONITORED FIRE ALARM SYSTEM | | | SHALL BE PROVIDED. | | | | | | 9.3 FIRE ALARM SYSTEMS. | | | 9.3.1 WHERE FIRE ALARM SYSTEMS ARE REQUIRED BY THIS | | | STANDARD THROUGHOUT THE ANIMAL HOUSING FACILITY, ALARM | | | SYSTEMS SHALL BE IN ACCORDANCE WITH NFPA 72, NATIONAL | | | FIRE ALARM CODE, AND THE REQUIREMENTS OF THIS SECTION. | | | 9.3.2 THE ALARM SYSTEM SHALL SOUND AN AUDIBLE AND | | | VISUAL EXTERIOR ALARM FOR PURPOSES OF INITIATING | | | EMERGENCY ACTION. | | | 9.3.2.1 MODIFICATIONS TO 9.3.2 SHALL BE PERMITTED TO | | | ACCOMMODATE THE NEEDS OF THE ANIMAL OCCUPANTS WITH | | | APPROVAL OF THE AHJ. | | | | | | YOU HAVE THE OPTION OF PROVIDING A LOCAL FIRE ALARM | | | SYSTEM. | | | | | | | | | | | | 14) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 15) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-11-07 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-11-07 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2016-11-07 11:57:46 | PERMIT #16110180 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | FAIL COMMENTS: | | | | | | 1) SHEET A-4: YOU SHOW A TRAVEL DISTANCE OF 94 FEET. | | | THIS IS A NON-SPRINKLERED BUILDING. PER NFPA 150: | | | 8.1.2.4* EXIT TRAVEL DISTANCES. | | | 8.1.2.4.1 IN ANIMAL HOUSING FACILITIES NOT SPRINKLERED | | | IN ACCORDANCE WITH SECTION 9.2, EXIT TRAVEL DISTANCE | | | SHALL NOT EXCEED 75 FT (23 M) FROM ANY POINT IN THE | | | FACILITY. | | | | | | 2) PLEASE INDICATE WHAT CATEGORY OF ANIMALS WILL BE | | | HOUSED IN THIS FACILITY. (CATEGORY A, CATEGORY B, OR | | | BOTH). | | | PLEASE SEE NFPA 150: 9.8 SPECIAL REQUIREMENTS FOR | | | CATEGORY A ANIMALS. | | | | | | 3) SHEET A-4: NOTE INDICATES THAT ONLY ONE (1) FIRE | | | EXTINGUISHER WILL BE PROVIDED. FIRE EXTINGUISHERS WILL | | | NEED TO BE PROVIDED PER NFPA 1, NFPA 101, AND NFPA 150. | | | | | | 4) SHEET A-4: LIFE SAFETY GENERAL NOTES INDICATE THAT | | | EGRESS REQUIREMENTS ARE IN COMPLIANCE WITH NFPA 101, | | | CHAPTERS 7 AND 12. PLEASE REVIEW NFPA 150 FOR | | | ADDITIONAL EGRESS REQUIREMENTS, IF ANY, AS NEEDED FOR | | | ANIMAL CATEGORY (A AND/OR B) AND ANIMAL HOUSING CLASS | | | (CLASS 1, 2, OR 3). | | | | | | 5) ADDITIONAL COMMENTS MAY BE NEEDED UPON REVIEW OF | | | RESUBMITTAL. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 644-7326 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2017-04-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-05 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-05 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2017-04-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-05 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-28 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2017-03-01 08:20:48 | RESUBMITTAL GIVEN TO CCOLE PER SKENNEDY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2017-02-27 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-02-27 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-02-27 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-01-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-01-30 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-01-17 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-01-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-01-12 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-20 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-15 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-14 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2016-12-15 11:02:50 | IMPACT FEES ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-29 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-03 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-15 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-15 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2016-12-15 17:21:42 | NO NUMBER ASSIGNED, PLANS STAMPED |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-11-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-29 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-29 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2016-11-29 12:44:01 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | CONTACT 561-233-5025 FOR MORE INFORMATION. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2017-04-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-05 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-05 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2017-04-05 16:19:30 | MECHANICAL PROVISO | | | 4/5/2017 | | | | | | THE PLANS HAVE BEEN APPROVED WITH EXCEPTION. | | | FAILURE TO CORRECT THE LISTED DEFICIENCY IN THE PLAN | | | PRIOR TO MECHANICAL INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT OF REINSPECTION FEES. | | | | | | 1) THE EXHAUST FAN CAPACITIES AND EXHAUST VENTILATION | | | CALCULATIONS FOR THE OVERNIGHT DOG AREA AND THE DOG | | | AREA NEED TO BE CORRECTED TO MEET THE REQUIREMENTS OF | | | TABLE 403.3 FBC-14 MECHANICAL. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2017-03-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-01 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-01 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2017-03-01 12:28:37 | 6TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #16110180 | | | 3/1/17 | | | | | | 1) THE REVISED EXHAUST VENTILATION AND AIR BALANCE | | | CALCULATIONS INDICATE ERV'S ARE REQUIRED FOR AHU'S #1, | | | 3, 4, & 5 BECAUSE THE THE AMOUNT OF O/A REQUIRED IS | | | EXCEEDING 50% OF THE DESIGN SUPPLY FAN AIRFLOW RATE- | | | SEE TABLE C403.2.6 FBC-14 ENERGY CONSERVATION. PLEASE | | | NOTE THAT A PRODUCT DATA SHEET HAS BEEN SUBMITTED FOR A | | | LIGHT COMMERCIAL ERV HOWEVER THE UNIT(S) ARE NOT SHOWN | | | ON THE PLAN. IT ALSO APPEARS THAT THE O/A REQUIRED FOR | | | THE OVERNIGHT DOG AREA AT 1397 CFMS WILL FAR EXCEED THE | | | COOLING CAPACITY OF THE 5-TON AHU-1 SYSTEM. | | | | | | 2) M-2: AC SYSTEMS #1, 4 & 5 ARE NOT FUNCTIONING IN THE | | | RETAIL AREA- PLEASE DESIGNATE THEIR LOCATIONS TO | | | CORRELATE WITH THE PLAN. | | | | | | 3) ADVISORY: TO AVOID ANY FURTHER PLAN REJECTIONS, | | | PLEASE CONSULT WITH A LICENSED MECHANICAL ENGINEER. | | | PLEASE NOTE THAT ALL OCCUPIED SPACES MUST BE PROVIDED | | | WITH EITHER NATURAL OR MECHANICAL VENTILATION (SECTION | | | 401.2), AND ACTIVE OR SPACE HEATING SYSTEMS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2017-02-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-22 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-22 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2017-02-22 12:36:19 | 5TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #16110180 | | | 1/22/17 | | | | | | 1) 4TH REQUEST FOR EXHAUST VENTILATION CALCULATIONS: | | | THE REQUESTED EXHAUST VENTILATION CALCULATIONS FOR THE | | | DOG AREA AND THE OVERNIGHT DOG PLAY AREA HAVE NOT BEEN | | | PROVIDED AS REQUIRED BY TABLE 403.3. CALCULATIONS BASED | | | ON THE SCALE SHOWN ON THE PLAN INDICATE 666 CFMS OF | | | EXHAUST REQUIRED FOR THE DOG AREA AND 683 CFMS FOR THE | | | OVERNIGHT DOG PLAY AREA. THE EF-1 FANS AT 110 CFMS | | | CAPACITY ARE ONLY PROVIDING 220 CFMS OF EXHAUST AT EACH | | | OF THESE ROOMS INDICATING INCREASED VENTILATION MUST BE | | | PROVIDED- SEE TABLE 403.3. | | | | | | 2) 4TH REQUEST FOR COMPLETE EXHAUST SYSTEM DRAWINGS: | | | THE REQUESTED DETAILS FOR THE EXHAUST SYSTEMS IN THE | | | DOG AREA AND OVERNIGHT DOG PLAY AREA HAVE NOT BEEN | | | PROVIDED. | | | | | | 2) PLEASE LABEL THE NEW EXHAUST AND SUPPLY FANS IN THE | | | INDOOR DOG PLAY AREA AND PROVIDE EQUIPMENT SCHEDULES. | | | | | | 3) REFER TO TABLE 403.3 AND PROVIDE AN O/A CALCULATION | | | FOR THE INDOOR PLAY AREA AND SHOW HOW O/A WILL BE | | | PROVIDED TO THE AREAS. CORRECT THE NOTE IN THE AIR | | | BALANCE CALCULATION THAT STATES "NO FRESH AIR THRU | | | AHU'S". | | | | | | 4) INDICATE THE SIZES OF THE MAIN DUCT TRUNKS | | | DISTRIBUTING AIR FROM AHU'S 3, 4 & 5. | | | | | | 5) THE PLAN APPEARS TO SHOW INADEQUATE AIR DISTRIBUTION | | | WILL BE PROVIDED TO THE BREATHING ZONES IN THE INDOOR | | | DOG PLAY AREA BASED ON THE DUCT LAYOUT PLAN PROVIDED. | | | | | | 6) A PRODUCT DATA SHEET FOR BROAN EXHAUST FANS HAS BEEN | | | SUBMITTED WITH MODEL NUMBERS THAT DON'T MATCH THE MODEL | | | NUMBERS ON THE EQUIPMENT SCHEDULES SHOWN ON THE PLANS- | | | PLEASE CORRECT ONE OR THE OTHER. | | | | | | 7) A PRODUCT DATA SHEET HAS BEEN SUBMITTED FOR A | | | SHUTTER FAN BUT NO LOCATION, DETAILS, OR SCHEDULE FOR | | | THE FAN ARE PROVIDED ON THE PLANS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2017-02-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-17 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-17 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2017-02-17 07:43:49 | 4TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #16110180 | | | 2/17/17 | | | | | | NO CORRECTIONS TO THE PLANS OR RESPONSES TO THE 3RD | | | REVIEW COMMENTS HAVE BEEN PROVIDED. I HAVE COPIED THE | | | COMMENTS BELOW FOR REVIEW- PLEASE COMPLY. | | | | | | 1) 3RD REQUEST FOR EXHAUST VENTILATION CALCULATIONS FOR | | | ALL SYSTEMS- TABLE 403.3 | | | | | | 2) 3RD REQUEST TO PROVIDE COMPLETE EXHAUST SYSTEM | | | DRAWINGS INCLUDING THE INDOOR DOG PLAY ROOMS. THE | | | DRAWINGS AND DETAILS SHALL INCLUDE THE EXHAUST DUCT | | | TYPES AND SIZES, DUCT RUNS AND TERMINATION LOCATIONS. | | | PLEASE NOTE THAT ENGINEERING DETAILS FOR INSTALLATION | | | OF ANY ROOFTOP FANS OR TERMINATION CAPS WILL BE | | | REQUIRED. | | | | | | 3) 2ND REQUEST FOR THE ARCHITECT OF RECORD TO PROVIDE | | | SHOP DRAWING APPROVAL OF THE AC CALCULATIONS. | | | | | | 4) 2ND REQUEST FOR THE ENERGY COMPLIANCE CHECKLIST TO | | | BE FILLED OUT. | | | | | | 5) 3RD REQUEST FOR COMPLETE AIR BALANCE CALCULATIONS. | | | PLEASE NOTE THE CALCULATION M-1 DOES NOT INCLUDE THE | | | O/A AIR SUPPLIED BY AHU-3 AND THE REQUIRED EXHAUST | | | SYSTEMS IN THE INDOOR DOG AREAS. | | | | | | 6) PROVIDE THE DUCT LAYOUT PLAN FOR AHU-3. | | | | | | 7) THE CU TIE DOWN DETAIL IS INCOMPLETE. PLEASE PROVIDE | | | THE GAUGE OF THE STEEL STRAP OR MANUFACTURER'S | | | SPECIFICATIONS, AND HOW THE CLIP WILL BE FASTENED TO | | | THE CONDENSER JACKET. | | | | | | 8) 2ND REQUEST TO SHOW THE LOCATION OF THE DS DETECTORS | | | IN THE RETURN AIR SYSTEMS OF THE AHU'S. | | | | | | 9) PLEASE CLARFY WHAT TYPE OF AUTOMATIC O/A DAMPERS ARE | | | PROPOSED FOR AHU'S 1 & 2. ARE THESE MOTORIZED DAMPERS? | | | IF SO, PLEASE SEE SECTION C402.4.5.2 FBC-14 ENERGY | | | CONSERVSATION AND PROVIDE MANUFACTURER'S | | | SPECIFICATIONS. | | | | | | 10) REFER TO SECTION 401.4 AND PROVIDE THE REQUIRED | | | CLEARANCE DISTANCE MEASUREMENTS FOR THE O/A INTAKES TO | | | EXHAUST OUTLETS OR OTHER CONTAMINANT SOURCES, AND | | | VEHICULAR DRIVE AREAS SUCH AS DRIVEWAYS AND PARKING | | | LOTS | | | | | | 11) INDICATE HOW THE O/A OPENINGS WILL BE PROTECTED IN | | | COMPLIANCE WITH SECTION 401.5. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-01-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-01-27 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-01-27 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2017-01-27 11:16:34 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #16110180 | | | 1/27/17 | | | | | | 1) 3RD REQUEST FOR EXHAUST VENTILATION CALCULATIONS FOR | | | ALL SYSTEMS- TABLE 403.3 | | | | | | 2) 3RD REQUEST TO PROVIDE COMPLETE EXHAUST SYSTEM | | | DRAWINGS INCLUDING THE INDOOR DOG PLAY ROOMS. THE | | | DRAWINGS AND DETAILS SHALL INCLUDE THE EXHAUST DUCT | | | TYPES AND SIZES, DUCT RUNS AND TERMINATION LOCATIONS. | | | PLEASE NOTE THAT ENGINEERING DETAILS FOR INSTALLATION | | | OF ANY ROOFTOP FANS OR TERMINATION CAPS WILL BE | | | REQUIRED. | | | | | | 3) 2ND REQUEST FOR THE ARCHITECT OF RECORD TO PROVIDE | | | SHOP DRAWING APPROVAL OF THE AC CALCULATIONS. | | | | | | 4) 2ND REQUEST FOR THE ENERGY COMPLIANCE CHECKLIST TO | | | BE FILLED OUT. | | | | | | 5) 3RD REQUEST FOR COMPLETE AIR BALANCE CALCULATIONS. | | | PLEASE NOTE THE CALCULATION M-1 DOES NOT INCLUDE THE | | | O/A AIR SUPPLIED BY AHU-3 AND THE REQUIRED EXHAUST | | | SYSTEMS IN THE INDOOR DOG AREAS. | | | | | | 6) PROVIDE THE DUCT LAYOUT PLAN FOR AHU-3. | | | | | | 7) THE CU TIE DOWN DETAIL IS INCOMPLETE. PLEASE PROVIDE | | | THE GAUGE OF THE STEEL STRAP OR MANUFACTURER'S | | | SPECIFICATIONS, AND HOW THE CLIP WILL BE FASTENED TO | | | THE CONDENSER JACKET. | | | | | | 8) 2ND REQUEST TO SHOW THE LOCATION OF THE DS DETECTORS | | | IN THE RETURN AIR SYSTEMS OF THE AHU'S. | | | | | | 9) PLEASE CLARFY WHAT TYPE OF AUTOMATIC O/A DAMPERS ARE | | | PROPOSED FOR AHU'S 1 & 2. ARE THESE MOTORIZED DAMPERS? | | | IF SO, PLEASE SEE SECTION C402.4.5.2 FBC-14 ENERGY | | | CONSERVSATION AND PROVIDE MANUFACTURER'S | | | SPECIFICATIONS. | | | | | | 10) REFER TO SECTION 401.4 AND PROVIDE THE REQUIRED | | | CLEARANCE DISTANCE MEASUREMENTS FOR THE O/A INTAKES TO | | | EXHAUST OUTLETS OR OTHER CONTAMINANT SOURCES, AND | | | VEHICULAR DRIVE AREAS SUCH AS DRIVEWAYS AND PARKING | | | LOTS | | | | | | 11) INDICATE HOW THE O/A OPENINGS WILL BE PROTECTED IN | | | COMPLIANCE WITH SECTION 401.5. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-27 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-27 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2016-12-27 08:49:02 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16110180 | | | 12/27/16 | | | | | | 1) THE REQUESTED EXHAUST FAN SCHEDULES AND EXHAUST | | | VENTILATION CALCULATIONS WERE NOT PROVIDED. | | | | | | 2) THE REQUESTED EXHAUST DUCT DETAILS- TYPES AND SIZES | | | OF DUCTS AND TERMINATION LOCATIONS WERE NOT PROVIDED. | | | | | | 3) THE REQUESTED AC CALCULATIONS MUST BEAR TRHE SHOP | | | DRAWING APPROVAL STAMP AND SIGNATURE OF THE DESIGN | | | PROFESSIONAL OF RECORD. | | | | | | 4) THE REQUESTED ENERGY COMPLIANCE SUBMITTAL WAS | | | SUBMITTED WITHOUT THE PRINTED OR SIGNED NAMES OF THE | | | DESIGN PROFESSIONALS OR THE OWNER/AGENT- SEE PAGE 3. | | | | | | 5) THE REQUESTED ENERGY COMPLIANCE SUBMITTAL WAS | | | SUBMITTED WITHOUT THE MANDATORY REQUIREMENTS CHECKLIST | | | COMPLETED- SEE PAGE 8. | | | | | | 6) THE ENERGY COMPLIANCE SUBMITTAL INCORRECTLY LISTS | | | TWO 5-TON AC SYSTEMS AT 16 SEER, HOWEVER ONLY THE NEW | | | SYSTEM IS 16 SEER. | | | | | | 7) THE REQUESTED AIR BALANCE CALCULATION WAS NOT | | | PROVIDED. | | | | | | 8) THE REQUESTED WIND LOAD ENGINEERING AND STRUCTURAL | | | DETAILS FOR THE CU AND CU PAD WERE NOT PROVIDED. | | | | | | 9) THE EQUIPMENT SCHEDULE FOR THE NEW 5-TON AC | | | INCORRECTLY LISTS THE WEIGHT AT 9.7 LBS. | | | | | | 10) DUCT SMOKE DETECTORS ARE REQUIRED IN THE RETURN AIR | | | SYSTEMS OF THE NEW AND EXISTING 5-TON AC SYSTEMS, | | | UNLESS MANUFACTURER'S SPECIFICATIONS INDICATE THE UNITS | | | ARE INCAPABLE OF PRODUCING OVER 2000 CFMS OF SUPPLY | | | AIR- SECTION 606.2.1. | | | | | | 11) PROVIDE AN AIR DEVICE SCHEDULE. | | | | | | 12) NEW DRYER: REFER TO SECTION 504 AND PROVIDE A) | | | MANFACTURER'S SPECIFICATIONS FOR THE DRYER. B) EXHAUST | | | DUCT DETAILS INCLUDING THE DUCT RUN AND DUCT | | | TERMINATION. C) MAKEUP AIR DETAILS- SEE SECTION 504.5. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-11-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-14 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-10 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2016-11-14 08:51:35 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING, | | | ENERGY CONSERVATION CODES | | | PERMIT #16110180 | | | 11/14/16 | | | | | | THE MECHANICAL PLANS DESIGNED BY SANDRA PUERTA | | | ARCHITECT ARE DEFICIENT AND NOT IN COMPLIANCE WITH | | | CURRENT CODES AND STANDARDS. | | | | | | 1) PROVIDE EQUIPMENT SCHEDULES ON THE PLAN FOR THE NEW | | | AND EXISTING AC SYSTEMS, AND THE VARIOUS EXHAUST FANS | | | SHOWN IN THE DRAWINGS. | | | | | | 2) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW AC SYSTEM- SECTION C403.2.1 FBC-14 ENERGY | | | CONSERVATION. | | | | | | 3) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE | | | AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | | ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL. | | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | | PROVIDED CFMS OF OUTDOOR AIR, AND THE REQUIRED AND | | | PROVIDED CFM'S OF EXHAUST AIR. | | | | | | 4) PROVIDE AN AIR BALANCE CALCULATION. | | | | | | 5) THE PROJECT IS DEFINED AS A CHANGE OF OCCUPANCY PER | | | SECTION 202 FBC-14 EXISTING BUILDING CODE. REFER TO | | | SECTION C101.4.4 FBC-14 ENERGY CONSERVATION AND SUBMIT | | | DOCUMENTATION OF COMPLIANCE. SEE SECTION 401.2 FOR | | | COMPLIANCE PATH OPTIONS. | | | | | | 6) PROVIDE AN AIR DEVICE SCHEDULE ON THE PLAN,. | | | | | | 7) INDICATE THE SIZES OF THE SUPPLY AND RETURN DUCTS, | | | DIFFUSERS, DISTRIBUTION BOXES, AND RETURN GRILLS SHOWN | | | ON THE LAYOUT DRAWING, AND SHOW CFM AMOUNTS AT EACH | | | SUPPLY DIFFUSER AND RETURN GRILL. | | | | | | 8) PROVIDE A COMPLETE DUCT LAYOUT FOR AHU-2 & AHU-3 | | | | | | 9) INDICATE HOW OUTSIDE AIR IS BEING SUPPLIED TO THE | | | ROOMS AND SPACES, AND REFER TO SECTION C403.2.4.4 FOR | | | SHUTOFF DAMPER REQUIREMENTS. | | | | | | 10) REFER TO TABLE 403.3 FOOTNOTE B: AIR FROM THE DOG | | | GROOMING ROOM IS NOT PERMITTED TO RECIRCULATE INTO THE | | | ADJACENT RETAIL AREA. | | | | | | 11) REFER TO TABLE 403.3 FOOTNOTE B: HOW IS AIR BEING | | | RETURNED TO AHU-3? NO RETURN DUCTS OR GRILLS ARE SHOWN. | | | PLEASE NOTE THAT AHU-1 MUST BE A COMPLETELY SEALED UNIT | | | WITH A DUCTED RETURN BECAUSE IT SHARES THE SAME | | | MECHANICAL CLOSET WITH AHU-2. THE AIR FROM THESE TWO | | | SYSTEMS CANNOT COMMUNICATE. | | | | | | 12) PROVIDE EXHAUST VENTILATION DETAILS: SHOW THE TYPES | | | AND SIZES OF EXHAUST DUCTS, THE DUCT RUNS, AND THE | | | TERMINATION LOCATIONS- SEE SECTION 501.2- 501.3.1.1. | | | | | | 13) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF | | | THE ACCU #3- SECTION 301.15. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-02-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-15 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-15 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2017-01-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-01-28 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-01-28 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2017-01-28 06:09:50 | 1) THE BREAK ROOM SINK SHALL COMPLY WITH THE 2014 | | | FBC-ACCESS. SECS.212, 606 AND 305. SHOW THE HEIGHT OF | | | THE TOP OF THE COUNTERTOP/SINK FROM THE FINISH FLOOR. | | | 2) THE WALL FINISH IN THE NEW TOILET ROMM SHALL COMPLY | | | WITH 2014 FBC SEC. 1210. SHT.THE FINISH SCHEDULE ON | | | SHT.A-2 SHOWS THE WALLS AS PAINT. CLARIFY. | | | 3) THE SANITARY RISER DOES NOT COMPLY WITH THE | | | FBC-PLUMBING CODE. | | | A) THE WASHING MACHINE SHALL BE INSTALLED ON A MINIMUM | | | 3 INCH STACK. FPC SEC.406.2. | | | B) THE DOG TUBS ARE NOT VENTED. FPC 901.2.1. | | | C) THE DISHWASHER SHALL DRAIN INDIRECTLY PER FPC | | | SEC.802.1.6. | | | D) THE DRINKING FOUNTAIN IS NOT VENTED. FPC 901.2.1. | | | 4) SHT. A-1 ( DEMO PLAN) IS MISSING. IT IS LISTED ON | | | THE COVER PAGE. CLARIFY. | | | 5) HOT WATER IS REQUIRED TO THE WASHING MACHINE. FPC | | | SEC.607.1. | | | 6) THE ENTIRE WATER SYSTEM ( HOT & COLD ) IS SIZED IN | | | 1/2 INCH PIPE. REFER TO FPC SEC.604.3. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-01-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-01-12 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-01-12 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2017-01-12 14:25:16 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHOW HEIGHT OF ACCESSIBLE SINK IN BREAK ROOM TO | | | COMPLY WITH FBC ACC 606.3 - 306 | | | | | | 2. SANITARY RISER DIAGRAM DOES NOT COMPLY WITH THE | | | CODE. PER WPB AMEND TO FBC 107.2.1 | | | | | | A) THE MOP SINK IS NOT VENTED. FBC PL 901.2.1 | | | B) ACCESSIBLE SINK IN BREAK ROOM IS NOT VENTED. FBC PL | | | 901.2.1 | | | C) DOG TUBS NOT VENTED. FBC PL 901.2.1 | | | D) WASHING MACHINE IS NOT VENTED. FBC PL 901.2.1 | | | E) THE WATER FOUNTAIN IS NOT SHOWN ON RISER DIAGRAM. | | | PER WPB AMEND TO FBC 107.2.1 | | | F)DRAIN LINE FOR WASHING MACHINE SHALL BE A MIN OF 3". | | | PER FBC PL 406.2 | | | G) EXISTING WASHER IS NOT SHOWN ON DEMO PLAN PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | H) THE BUILDING DRAIN SERVING THE WASHING MACHINE, DOG | | | TUBS, BREAKROOM SINKS AND MOP SINK SHALL CONNECT DOWN | | | STREAM OF BATHROOM GROUP IT CAN'T CONNECT BETWEEN THE | | | TOILET AND LAV. FBC PL 912.1 | | | | | | 3. THE WATER RISER DIAGRAM IS UNCLEAR PLEASE ENLARGE | | | AND MAKE IT CLEAR TO READ. PER WPB AMEND TO FBC 107 | | | 107.2.1.4 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-11-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-11-27 |
Time |
05:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-11-27 |
Time |
03:24 |
Sent To |
|
|
| Notes |
| 2016-11-27 04:50:32 | 1) SHT. CVR OF 10 - THE OCCUPANCY CLASSIFICATION IS | | | LISTED AS "IIIB". THIS IS A MIXED OCCUPANCY. LIST ALL | | | APPLICABLE OCCUPANCY TYPES AND THE CORRESPONDING | | | OCCUPANT LOAD FOR EACH AREA IN ACCORDANCE WITH 2014 FBC | | | CHAPTER 3 AND SEC.1004. | | | 2) THIS IS A CHANGE OF OCCUPANCY AND SHALL COMPLY WITH | | | THE PLUMBING FIXTURE REQUIREMENTS OF THE 2014 | | | FBC-PLUMBING, LIST THE PREVIOUS OCCUPANCY ON THE PLANS. | | | TABLE 403.1. | | | 3) DRINKING FOUNTAINS ARE REQUIRED PER 2014 | | | FBC-PLUMBING TABLE 403.1. A MINIMUM OF 2 DRINKING | | | FOUNTAINS ARE REQUIRED PER TABLE 403.1 FOOTNOTE (E) AND | | | 2014 FBC-ACCESS. SEC.211.2. SUBMIT ELEVATION DETAILS. | | | 4) THE BREAK ROOM SINK SHALL COMPLY WITH THE 2014 | | | FBC-ACCESS. SECS.212, 606 AND 305. SHOW THE HEIGHT OF | | | THE TOP OF THE COUNTERTOP FROM THE FINISH FLOOR AND THE | | | REQUIRED CLEAR FLOOR SPACE FOR THE SINK. | | | 5) A SERVICE SINK IS REQUIRED PER 2014 FBC-PLUMBING | | | TABLE 403.2. | | | 6) SEPARATE FACILITIES ARE REQUIRED FOR MALES AND | | | FEMALES PER TABLE 403.1 OF 2014 FBC-PLUMBING. | | | 7) SHT. A-3 DETAIL 4 (A) - THE PLACEMENT OF THE GRAB | | | BAR ON THE REAR WALL SHALL COMPLY WITH 2014 FBC- | | | ACCESS. SEC. 604.5.2 & FIGURE 504.5.2. | | | 8) THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | | GRIPPING SURFACE PER THE2014 FBC-ACCESS. SEC. 609.4. | | | 9) SHT.A-3 - DETAIL 5 - SHOWS THE TOP OF THE LAVATORY | | | AT 40 INCHES ABOVE THE FINISH FLOOR AND 34 INCHES IS | | | SHOWN TO THE BACKSPLAS. THE MAXIMUM HEIGHT OF THE | | | LAVATORY SHALL COMPLY WITH 2014 FBC- ACCESS. SEC.606.3. | | | 10) THE FLUSH HANDLE FOR THE WATER CLOSET SHALL BE | | | LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. | | | FBC-ACCESS. SEC.604.6. | | | 11) SHT.A-3 DETAIL 6 REFERENCES THE 2010 FBC. THIS | | | SCOPE OF WORK SHALL COMPLY WITH 2014 FBC. | | | 12) THE WALL FINISH IN THE NEW TOILET ROMM SHALL COMPLY | | | WITH 2014 FBC SEC. 1210. | | | 13) SUBMIT A SANITARY AND WATER RISER FOR REVIEW THAT | | | SHOWS ALL PLUMBING FIXTURES (DRINKING FOUNTAIS, MOP | | | SINK, BREAK ROOM SINK, WASHER, DOG WASH TUBS, WATER | | | HEATER). | | | 14) WILL THERE BE ANY HOSE BIBBS INSTALLED FOR WASHING | | | DOWN THE DOG AREAS? IF SO, SHOW THEM ON THE WATER | | | RISER. EACH HOSE BIBB SHALL BE EQUIPPED WITH SEPARATE | | | SHUTOFF VALVE. FPC SEC.606.2. | | | 15) HOT WATER IS REQUIRED TO THE NEW MOP SINK. 2014 FPC | | | SEC.607.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-03-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2017-03-07 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-01-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-01-30 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-01-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-01-04 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-22 |
|
|
Cont ID |
|
| Sent By |
AW |
Date |
2016-11-22 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2016-11-22 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2016-11-22 08:39:01 | ******ZONING******** | | | | | | BUSINESS TAX LICENSE NEEDED. |
|
|