Plan Review Details - Permit 16100946
Plan Review Stops For Permit 16100946
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-11-10 Cont ID  
Sent By cthroop Date 2016-11-10 Time 14:15 Rev Time 0.00
Received By cthroop Date 2016-11-10 Time 13:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-12-08 Cont ID  
Sent By mvaldes Date 2016-12-08 Time 09:10 Rev Time 0.00
Received By mvaldes Date 2016-12-08 Time 09:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-11-02 Cont ID  
Sent By cthroop Date 2016-11-10 Time 13:29 Rev Time 0.00
Received By vperez Date 2016-11-02 Time 13:38 Sent To P
Notes
2016-11-02 13:39:08INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. PROVIDE REVISED PANEL LOAD SCHEDULE REFLECTING NEW
 HOOD, LIGHTING AND RANGE LOADS. FBC 107.3.5
 2. PROVIDE A NOTE TO INDICATE REQUIRED TAMPER RESISTANT
 RECEPTACLE THROUGHOUT. FBC RES E4002.14
 3. PROVIDE A NOTE PER FBC ENERGY CONSERVATION CODE TO
 INDICATE; 75% OF LAMPS TO HIGH EFFICACY LAMPS.
 4. ADDRESS SPACING FOR COUNTERTOP RECEPTACLES IN
 KITCHEN PER FBC RES E3901.4 TO THE RIGHT OF PENINSULA
 WHERE SINK BREAKS COUNTERTOP AREA.
 5. PROVIDE A NOTE TO PROVIDE AFCI PROTECTION PER FBC
 RES E3902.12 FOR NEW LIGHTING CIRCUITS.
 6. FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY
 QUESTIONS OR CONCERNS.
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-14 Cont ID  
Sent By gjohnson Date 2016-12-14 Time 08:17 Rev Time 0.00
Received By gjohnson Date 2016-11-28 Time 17:23 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-10 Cont ID  
Sent By cthroop Date 2016-11-10 Time 13:29 Rev Time 0.00
Received By cthroop Date 2016-10-31 Time 13:09 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-12-14 Cont ID  
Sent By gjohnson Date 2016-12-14 Time 08:17 Rev Time 0.00
Received By tklarge Date 2016-11-29 Time 08:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2016-11-08 Time   Rev Time 0.00
Received By tklarge Date 2016-11-08 Time 04:13 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved