Plan Review Details - Permit 16100880
Plan Review Stops For Permit 16100880
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-11-14 Cont ID  
Sent By jwitmer Date 2016-11-14 Time 17:18 Rev Time 0.00
Received By shill Date 2016-11-14 Time 17:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-11-07 Cont ID  
Sent By mvaldes Date 2016-11-07 Time 10:04 Rev Time 0.00
Received By mvaldes Date 2016-11-07 Time 09:50 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2017-01-13 Cont ID  
Sent By gjohnson Date 2017-01-25 Time 11:21 Rev Time 1.00
Received By mgonzale Date 2017-01-13 Time   Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-11-03 Cont ID  
Sent By pleduc Date 2016-11-03 Time   Rev Time 0.00
Received By pleduc Date 2016-11-03 Time 10:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-01-25 Cont ID  
Sent By gjohnson Date 2017-01-25 Time 11:21 Rev Time 0.00
Received By gjohnson Date 2016-11-21 Time 15:30 Sent To ENG
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-21 Cont ID  
Sent By cpuell Date 2016-11-21 Time 15:30 Rev Time 0.00
Received By cpuell Date 2016-10-28 Time 10:16 Sent To  
Notes
2016-10-31 10:16:26B06

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-11-14 Cont ID  
Sent By shill Date 2016-11-14 Time 17:36 Rev Time 0.00
Received By shill Date 2016-11-14 Time 17:36 Sent To  
Notes
2016-11-14 17:37:03****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY MAY BE
 REQUIRED. CONTACT 561-233-5025 FOR MORE INFORMATION.
  
 IF REQUIRED, THE PLANS ARE TO BE STAMPED AND THE
 RECEIPT SHOWING THAT FEES DUE (IF APPLICABLE) HAVE BEEN
 PAID IS TO BE PROVIDED.
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-06-30 Cont ID  
Sent By gjohnson Date 2017-06-30 Time 16:38 Rev Time 0.00
Received By gjohnson Date 2017-06-30 Time 16:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-01-24 Cont ID  
Sent By gjohnson Date 2017-01-24 Time 17:38 Rev Time 0.00
Received By gjohnson Date 2017-01-24 Time 17:38 Sent To  
Notes
2017-01-24 17:39:552ND REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS: 2ND REQUEST
  
 1. BATH # 1 ELEVATIONS BATH#2 MIRRORED PER FBC ACC
 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES
 OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE
 OF THE REFLECTING SURFACE 35 INCHES (890 MM) MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND.
 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 2. SANITARY RISER NEW NURSING STATION THE SINK IS NOTE
 VENTED. PER FBC PL 901.2.1
  
 3. SANITARY RISER BATH # 3 NEW SINK NOT VENTED. PER FBC
 PL 901.2.1
  
 4. SANITARY RISER BATH # 3 #4 REMOVE VENTS FROM WC NOT
 NEEDED BATHROOM VENTED BY SINK VENT. PER FBC PL 901.2.1
  
 5. KITCHEN AND NEW PHARMACY SANITARY TABLE SINK LABELED
 AS HAND SINK PLEASE CLARIFY. PER WPB AMEN TO FBC
 107.2.1.
  
 6. SHOW VENT FOR TABLE SINK SLOP SINK AND EXISTING
 WASHING MACHINE. PER FBC PL 901.2.1
  
 7. THE 3 COMPARTMENT SINK , FLOOR DRAIN AND TABLE SINK
 AND SLOPE SINK ARE REQUIRED TO CONNECT TO A GREASE
 INTERCEPTOR. PER FBC PL 1003.1
  
 8. PLEASE PROVIDE MANUFACTURE SPECIFICATION AND
 CALCULATIONS FOR GREASE INTERCEPTOR. PER WPB AMEN TO
 FBC 107.2.1.
  
 9. THE FLOOR DRAIN SHALL BE EQUIPPED WITH A TRAP
 PRIMER. FBC PL 1002.4

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-11-14 Cont ID  
Sent By gjohnson Date 2016-11-14 Time 15:26 Rev Time 0.00
Received By gjohnson Date 2016-11-14 Time 15:26 Sent To  
Notes
2016-11-14 15:53:291ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. BATH # 1 ELEVATIONS BATH#2 MIRRORED PER FBC ACC
 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES
 OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE
 OF THE REFLECTING SURFACE 35 INCHES (890 MM) MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND.
 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 2. SANITARY RISER NEW NURSING STATION THE SINK IS NOTE
 VENTED. PER FBC PL 901.2.1
  
 3. SANITARY RISER BATH # 3 NEW SINK NOT VENTED. PER FBC
 PL 901.2.1
  
 4. SANITARY RISER BATH # 3 #4 REMOVE VENTS FROM WC NOT
 NEEDED BATHROOM VENTED BY SINK VENT. PER FBC PL 901.2.1
  
 5. KITCHEN AND NEW PHARMACY SANITARY TABLE SINK LABELED
 AS HAND SINK PLEASE CLARIFY. PER WPB AMEN TO FBC
 107.2.1.
  
 6. SHOW VENT FOR TABLE SINK SLOP SINK AND EXISTING
 WASHING MACHINE. PER FBC PL 901.2.1
  
 7. THE 3 COMPARTMENT SINK , FLOOR DRAIN AND TABLE SINK
 ARE REQUIRED TO CONNECT TO A GREASE INTERCEPTOR. PER
 FBC PL 1003.1
  
 8. PLEASE PROVIDE MANUFACTURE SPECIFICATION AND
 CALCULATIONS FOR GREASE INTERCEPTOR. PER WPB AMEN TO
 FBC 107.2.1.
  
 9. THE FLOOR DRAIN SHALL BE EQUIPPED WITH A TRAP
 PRIMER. FBC PL 1002.4

Review Stop Z ZONING
Rev No 1 Status P Date 2016-11-17 Cont ID  
Sent By llouie Date 2016-11-17 Time   Rev Time 0.00
Received By llouie Date 2016-11-17 Time   Sent To  
Notes
2016-11-17 17:21:06ZONING PASSED WITH THE FOLLOWING PROVISOS:
  
 1.) MAXIMUM OF 15 BEDS PERMITTED.
  
 2.) USE IS SUBJECT TO THE CONDITIONS OUTLINED IN THE
 SETTLEMENT AGREEMENT (ATTACHED WITH PERMIT SETS).