| Plan Review Stops For Permit 16100873 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-01-25 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-26 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-01-25 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2017-01-25 12:54:19 | ****PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PROVISO; SHOP DRAWINGS OR PRODUCT APPROVAL REQUIRED | | | FOR REAR EXIT DOOR, FBC 1008, PANIC DEVICE OR FIRE EXIT | | | HARDWARE REQUIRED. INSTALLATION OF A NEW DOOR REQUIRES | | | A REVISION AND PRODUCT APPROVAL. MODIFICATION OF AN | | | EXISTING DOOR MAY REQUIRE A REVISION SUBJECT TO THE | | | FIELD INSPECTOR'S DISCRETION. | | | | | | 3. ALL DOORS AND GATES ARE TO INCLUDE PANIC HARDWARE, | | | FBC 1008.1.10, 1008.2. | | | | | | 3. PER ARCHITECT, ALL BENCHES ARE MOVEABLE - ADDITION | | | OF ANY BUILT IN BENCHES REQUIRE A REVISION OR, IF DONE | | | AFTER THIS PERMIT IS CLOSED, A SEPARATE PERMIT. | | | | | | 4. FBC A 403.3. THIS APPEARS TO BE A RAMP; RISE CANNOT | | | EXCEED 6 INCHES. IF RISE EXCEEDS 6 INCHES, HANDRAILS | | | AND EDGE PROTECTION ARE REQUIRED (AND A REVISION IS | | | REQUIRED). THIS COMMENT APPLIES TO THE 1/12 DOWNWARD | | | SLOPE LEADING TO THE RAMP AT THE REAR OF THE BUILDING. | | | SHEET A1 APPEARS TO SHOW HANDRAILS FOR THIS PORTION, | | | SHEET A3 DOES NOT. | | | | | | 5. MEANS OF EGRESS ILLUMINATION REQUIRED IN THE EXIT | | | DISCHARGE TO THE PUBLIC WAY, FBC 1027. | | | | | | 6. THIS IS A CHANGE OF OCCUPANCY AND SHALL COMPLY WITH | | | ALL REQUIREMENTS OF FBC EXISTING BUILDING CHAPTER 10. | | | PLANS HAVE BEEN REDLINED TO NOTE CHANGE OF OCCUPANCY. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-13 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-13 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2016-12-13 12:07:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | 2. THIS PROJECT INCLUDES A CHANGE OF OCCUPANCY. SEE FBC | | | 5TH EDITION EXISTING BUILDING CHAPTER 10. REVISE PLAN | | | TO SHOW COMPLIANCE WITH ALL REQUIREMENTS. | | | | | | 2ND REVIEW, INFORMATION REGARDING THE EXISTING | | | OCCUPANCY WAS NOT PROVIDED. | | | | | | COMPLIANCE WITH THE FOLLOWING IS NOT CLEAR: | | | | | | FBC EB TABLE 1012.5, FBC B TABLE 503, AS CHANGE OF | | | OCCUPANCY IS PROPOSED TO A HIGHER HAZARD, COMPLIANCE | | | WITH FBC B CHAPTER 5 IS REQUIRED. IT APPEARS THAT THE | | | PROPOSED NEW OCCUPANCY MAY COMPLY, BUT REQUIRES | | | CALCULATIONS AND INFORMATION REGARDING THE EXISTING | | | OCCUPANCIES TO BE PROVIDED FBC B 503.1. | | | | | | FBC EB TABLE 1012.6, APPEARS TO COMPLY, BUT NO | | | INFORMATION PROVIDED (FROM S1 OR S2 TO A OR B? B TO A?) | | | | | | 6. SEE IMPACT FEE REVIEW. | | | | | | THIS IS REQUIRED PRIOR TO PERMIT ISSUANCE BUT MAY BE | | | DONE AFTER ALL REVIEWS HAVE PASSED. | | | | | | NEW COMMENT: | | | | | | THE DOOR IN THE WOMENS RESTROOM SWINGS INTO THE CLEAR | | | FLOOR SPACE, FBC A 603.2.3. | | | | | | PROVISO, DETAILS FOR TOILET DO NOT COMPLY, HEIGHT TO BE | | | MEASURED AT TOP OF SEAT, FBC A 604.4, REVISE DETAILS. | | | | | | * * * * * * * * * * * * * | | | | | | THE FOLLOWING ITEMS WERE ADDRESSED IN A RESPONSE | | | LETTER. IF THE SHEETS ARE REVISED DUE TO OTHER TRADES, | | | REVISE THE PLAN TO INCORPORATE THE INFORMATION. | | | | | | 1. PROVISO; SHOP DRAWINGS OR PRODUCT APPROVAL REQUIRED | | | FOR REAR EXIT DOOR, FBC 1008. | | | | | | 3. PROVIDE A DETAIL FOR THE STORAGE RACKS, FBC 107. | | | PROVIDE INFORMATION REGARDING THE EQUIPMENT TO BE | | | STORED THERE AND THE WEIGHT OF ITEMS TO BE STORED ON | | | THE RACKS. | | | | | | 8. ALL DOORS AND GATES ARE TO INCLUDE PANIC HARDWARE, | | | FBC 1008.1.10, 1008.2. REVISE PLAN TO SPECIFY. (DOORS | | | SPECIFIED, REVISE TO INCLUDE GATES) | | | | | | 10. INCORPORATE INFORMATION REGARDING THE BENCH SEATS | | | INTO THE PLAN, FBC 5TH EDITION ACCESSIBILITY 903. PER | | | RESPONSE LETTER THEY ARE MOVEABLE AND BACKLESS. | | | | | | 18. THE SLOPE EXCEEDS THE MAXIMUM SLOPE OF 1:20 (1:12 | | | SHOWN), FBC A 403.3. THIS APPEARS TO BE A RAMP; RISE | | | CANNOT EXCEED 6 INCHES. IF RISE EXCEEDS 6 INCHES, | | | HANDRAILS AND EDGE PROTECTION ARE REQUIRED (AND A | | | REVISION IS REQUIRED). | | | | | | 19. REVISE PLAN TO INCLUDE THE EXIT DISCHARGE TO THE | | | PUBLIC WAY, FBC 1027. SHOW COMPLIANCE WITH ALL | | | REQUIREMENTS, INCLUDING ILLUMINATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-07 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-04 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2016-11-07 15:06:42 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PLAN SHOWS AN EXISTING DOOR TO HAVE A PANIC BAR | | | INSTALLED. PROVIDE PRODUCT INFORMATION FOR THE EXISTING | | | DOOR AND FOR THE PROPOSED PANIC HARDWARE. EXTERIOR | | | DOORS ARE TESTED WITH HARDWARE, SO IT IS NOT CLEAR HOW | | | THIS WILL AFFECT THE INTEGRITY OF THE DOOR, FBC 1609, | | | 107. | | | | | | 2. THIS PROJECT INCLUDES A CHANGE OF OCCUPANCY. SEE FBC | | | 5TH EDITION EXISTING BUILDING CHAPTER 10. REVISE PLAN | | | TO SHOW COMPLIANCE WITH ALL REQUIREMENTS. | | | | | | 3. PROVIDE A DETAIL FOR THE STORAGE RACKS, FBC 107. | | | PROVIDE INFORMATION REGARDING THE EQUIPMENT TO BE | | | STORED THERE AND THE WEIGHT OF ITEMS TO BE STORED ON | | | THE RACKS. | | | | | | 4. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB, | | | INCLUDING A COST BREAKDOWN FOR ALL WORK INCLUDING LABOR | | | AND MATERIALS, OVERHEAD AND PROFIT, INCLUDING ITEMS | | | ALREADY INSTALLED WITHOUT PERMIT (PROVIDE VALUE OF WHAT | | | A CONTRACTOR WOULD HAVE CHARGED FOR THE WORK TO BE | | | DONE), FBC 109. VALUE IS TOO LOW. FAILURE TO PROVIDE AN | | | ACCURATE VALUE WILL RESULT IN PERMIT ISSUANCE DELAY. | | | | | | 5. THE RATIONALE FOR BUSINESS OCCUPANCY IS NOT CLEAR. | | | REVISE PLAN TO INCLUDE INFORMATION AS TO USE OF EACH | | | AREA. THE TWO SMALL OFFICES ARE BUSINESS, BUT THE REST | | | OF THE SPACE APPEARS TO BE ASSEMBLY, FBC CHAPTER 3. | | | | | | 6. SEE IMPACT FEE REVIEW. | | | | | | 7. REVISE PLAN TO INCLUDE INFORMATION REGARDING THE | | | GAME AREA. PROVIDE A SPECIFICATION FOR THE NETTING AND | | | THE DOORS, FBC 107. | | | | | | 8. ALL DOORS AND GATES ARE TO INCLUDE PANIC HARDWARE, | | | FBC 1008.1.10, 1008.2. REVISE PLAN TO SPECIFY. | | | | | | 9. SEE FBC 303.3, EXPLAIN RATIONALE FOR OCUPANCY A2, | | | USES INTENDED FOR FOOD AND DRINK. | | | | | | 10. PROVIDE A DETAIL FOR THE BENCH SEATS, FBC 5TH | | | EDITION ACCESSIBILITY 903. | | | | | | 11. PROVIDE A DETAIL FOR THE SALES AND SERVICE COUNTER | | | OR CHECK OUT AISLE, FBC 5TH EDITION ACCESSIBILITY 9 04. | | | | | | 12. IDENTIFY THE UNIDENTIFIED RECTANGLE ADJACENT TO THE | | | DOOR IN THE EQUIPMENT AREA, FBC 107. | | | | | | 13. REVISE PLAN TO SHOW THE 18 INCH MANEUVERING | | | CLEARANCE FOR THE DOOR FOR THE UNIDENTIFIED ROOM | | | ADJACENT TO THE PROPOSED REST ROOMS A2, FBC 5TH EDITION | | | ACCESSIBILITY 404.2.4.1. | | | | | | 14. PROPOSED FLOOR PLAN INCLUDES DEMO AREA FOR THE REST | | | ROOMS BUT NOT THE PROPSED PLAN, REVISE PLAN TO BE | | | CONSISTENT WITH THE NAME OF THE DETAIL. IF NECESSARY, | | | PROVIDE A DEMO PLAN TO CLARIFY, FBC 107. | | | | | | 15. A3 RAMP DETAIL HAS OLD CODE REFERENCE, REVISE TO | | | CURRENT, FBC 5TH EDITION ACCESSIBILITY. | | | | | | 16. REVISE PLAN TO SHOW THE RISE OF THE RAMP, FBC 5TH | | | EDITION ACCESSIBILITY 405.6. | | | | | | 17. REAR DOOR AT RAMP, CLARIFY DOOR SWING. ONE PAGE | | | SHOWS A RIGHT HAND, ANOTHER PAGE SHOWS LEFT. DOORS ARE | | | TO HAVE 18 IN MANEUVERING CLEARANCE ON THE PULL SIDE, | | | FBC 5TH EDITION ACCESSIBILITY 404.2.4.1. | | | | | | 18. RAMP DETAIL SHOWS A SLOPE DOWN, A LANDING, AND A | | | RAMP UP. REVISE PLAN TO INCLUDE THE SLOPE, FBC 107. | | | | | | 19. REVISE PLAN TO INCLUDE THE EXIT DISCHARGE TO THE | | | PUBLIC WAY, FBC 1027. SHOW COMPLIANCE WITH ALL | | | REQUIREMENTS, INCLUDING ILLUMINATION. | | | | | | 20. HANDRAIL EXTENSION REQUIRED AT THE TOP OF THE RAMP, | | | FBC 5TH EDITION 505.10. | | | | | | 21. SHOW THE ACCESSIBLE ROUTE FROM THE PUBLIC WAY AND | | | FROM ACCESSIBLE PARKING SPACE TO THE ALTERED AREA, FBC | | | 5TH EDITION 202.4. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-01-26 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-25 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-25 |
Time |
10:26 |
Sent To |
B |
|
| Notes |
| 2017-01-25 11:08:57 | 3RD REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | PASSED WITH THE FOLLOWING PROVISO'S | | | | | | 1] EXIT & EMERGENCY LIGHTING REQUIRED PER FBC 1006 & | | | 1011. (MEANS OF EGRESS ILLUMINATION FOR EXIT DISCHARGE) | | | | | | 2] ELECTRICAL LOAD CALCULATIONS, SINGLE LINE RISER | | | DIAGRAM INCLUDING WIRE & CONDUIT SIZES, & PANEL | | | SCHEDULES SHALL BE SUBMITTED FOR TENANT PERMIT # | | | 16100033. | | | | | | 3] FBC-E SECTION C101.4.4 CHANGE IN OCCUPANCY OR USE. | | | SPACES UNDERGOING A CHANGE IN OCCUPANCY THAT WOULD | | | RESULT IN AN INCREASE IN DEMAND FOR EITHER FOSSIL FUEL | | | OR ELECTRICAL ENERGY SHALL COMPLY WITH THIS CODE. | | | WHERE THE USE IN A SPACE CHANGES FROM ONE USE IN TABLE | | | C405.5.2(1) OR (2) TO ANOTHER USE IN TABLE C405.5.2(1) | | | OR (2), THE INSTALLED LIGHTING WATTAGE SHALL COMPLY | | | WITH SECTION C405.5. | | | | | | 4] ELECTRIC WATER FOUNTAINS REQUIRES GFCI PROTECTION | | | PER NEC 422.52 | | 2017-01-25 10:44:27 | ROUTED TO SH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-01-04 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-04 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-04 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2017-01-04 10:02:09 | 2ND REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1] NEW DRAWING INDICATE A ELECTRIC WATER FOUNTAIN | | | THEREFORE THE POWER OUTLET MUST BE GFCI PROTECTED PER | | | NEC 422.52. (SHOW COMPLIANCE) | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-01-26 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-11-02 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-11-02 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2016-11-02 18:23:40 | 1ST REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | - NO ELECTRICAL INFORMATION, PLEASE PROVIDE AN | | | ELECTRICAL SCOPE OF WORK. INCLUDE THE FOLLOWING ITEMS | | | | | | 1] SHOW A DETAIL FOR OBSTRUCTED AND UNBOSTRUCTED REACH | | | RANGES OF DEVICES IN ACCORDANCE WITH FBC-A SECTION 308. | | | | | | 2] SHOW A DETAIL FOR THE MEANS OF SUPPORT OF THE LAY IN | | | LUMINAIRE TO THE SUSPENDED CEILING PER NEC 410.36(B). | | | | | | 3] THE ADA RAMP WILL BE A MEANS OF EGRESS EXIT | | | DISCHARGE THEREFORE ILLUMINATION IS REQUIRED. | | | FBC-1006.1 (SHOW COMPLIANCE). |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-12-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-12-20 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-12-20 |
Time |
11:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-11-10 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-11-10 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-11-10 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2016-11-10 10:08:26 | 1500 NORTH FLORIDA MANGO ROAD - SUITE #14 & #15 | | | PERMIT #16100873 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE PLANS INDICATE A LIMITED WORK SCOPE OF BATHROOM | | | RENOVATIONS AND ADA RAMP; HOWEVER, A COMPLETE SET OF | | | PLANS ARE NEEDED AS THIS APPEARS TO BE A CHANGE OF | | | OCCUPANCY FROM MERCANTILE TO A MIXED USE | | | ASSEMBLY/BUSINESS OCCUPANCY. "CMS INDOOR ACTION SPORTS" | | | APPLIED FOR A BUSINESS TAX EARLIER THIS YEAR (2016) BUT | | | NO PERMITS COULD BE LOCATED SUPPORTING THE CHANGE OF | | | USE. | | | | | | PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY TYPES, | | | OCCUPANT LOADS, FIRE RATED WALLS, OCCUPANCY | | | SEPARATIONS, EXITS, EXIT SIGNS, EMERGENCY LIGHTING, | | | TRAVEL DISTANCES, COMMON PATH OF TRAVEL, PANIC DOOR | | | HARDWARE ETC. | | | | | | NO FLAME SPREAD OR SMOKE OBSCURATION INFORMATION | | | PROVIDED ON THE FLOORING, WALL COVERINGS, CEILING ETC. | | | | | | TWO EXIT DOORS FROM TWO DIFFERENT TENANTS ARE BEING | | | FUNNELED DOWN ONE EGRESS ADA RAMP. REDUCED EGRESS WIDTH | | | IS NOT PERMITTED. | | | | | | GUARDS, AT LEAST 42-INCHES TALL, SHALL BE PROVIDED AT | | | THE OPEN SIDES OF MEANS OF EGRESS (STAIRS, MEZZANINE, | | | ETC.) THAT EXCEED 30-INCHES ABOVE THE FLOOR. OPEN | | | GUARDS SHALL PROHIBIT THE PASSAGE OF A 4-INCH DIAMETER | | | SPHERE UP TO A HEIGHT OF 34-INCHES. | | | | | | HOW IS THE EGRESS RAMP BEING PROTECTED FROM VEHICULAR | | | TRAFFIC OR BLOCKED CARS? | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | UPDATE THE CODE LIST TO REFERENCE THE 5TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED | | | AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON | | | THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED DURING PLAN RESUBMISSION. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-01-26 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-26 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-25 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2017-01-25 10:10:50 | 1/25 ROUTED TO MV DESK | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-01-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-01-09 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-08 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-18 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-10-28 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2016-11-02 16:33:38 | ROUTED TO MARIO VALDEZ 11/02/16 - JORGE V. | | 2016-11-01 12:48:08 | B15 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2017-01-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-01-25 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-01-25 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2017-01-25 14:57:41 | MU 2017-663 | | | $0 DUE | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-07 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-07 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2016-11-07 07:52:17 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES DUE HAVE BEEN PAID (IF APPLICABLE) IS TO BE | | | PROVIDED. | | | | | | 561-233-5025 FOR MORE INFORMATION | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2016-11-02 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-11-02 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-11-02 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
N |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-07 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-07 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2016-11-07 07:54:29 | THIS PROPERTY IS LOCATED IN A SPECIAL HAZARD FLOOD AREA | | | CUMULATIVE 5 YEAR IMPROVEMENTS ARE $118,253; PAPA 2016 | | | VALUE FOR STRUCTURE IS $4,469,726 (3%); NOT A | | | SUBSTANTIAL IMPROVEMENT | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-01-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-01-09 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-01-09 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-11-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-09 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-08 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2016-11-08 16:15:48 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. VALUATIONS SEEMS LOW PLEASE PROVIDE BONA FIDE SIGNED | | | CONTRACTS WITH PRICE BREAK DOWN FOR ALL TRADES. PER WPB | | | AMEND. TO FBC 109.3 | | | | | | 2. ALL ACCESSIBILITY ELEMENTS SHALL COMPLY WITH THE | | | FLORIDA BUILDING CODE | | | 5TH EDITION (2014) ACCESSIBILITY WITCH DIFFERS FROM THE | | | ADA/ ANZI -A117.1 | | | PLEASE CHECK YOUR NOTES TO ENSURE THEY ALL COMPLY WITH | | | FBC ACC AND REMOVE REFERENCE TO ADA/ ANZI-A117.1 | | | PER WPB AMENS. TO FBC 107.2.1 | | | | | | 3. SHOW COMPLIANCE FORTOILET PAPER DISPENSERS SHALL | | | COMPLY WITH 309.4 AND SHALL BE 7 INCHES (180 MM) | | | MINIMUM AND 9 INCHES (230 MM) MAXIMUM IN FRONT OF THE | | | WATER CLOSET MEASURED TO THE CENTERLINE OF THE | | | DISPENSER. PER FBC ACC 604.7 | | | | | | 4. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | | POSITION, 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 | | | MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP | | | OF THE GRIPPING SURFACE NOT CENTERLINE OF BAR. PER FBC | | | ACC 609.4 | | | | | | 5. THE REAR WALLL GRAB BAR SHALL BE 36 INCHES (915 MM) | | | LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE | | | WATER CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND | | | 24 INCHES (610 MM) MINIMUM ON THE OTHER SIDE IF TOILET | | | IS SET AT 18" OFF SIDE WALL YOU WILL HAVE 6" FROM END | | | OF THE BAR TO THE SIDE WAL YOU ARE SHOWING 2" PLEASE | | | CLARIFY . PER FBC ACC 604.5.2 | | | | | | 6. A WATER FOUNTAIN COMPLYING WITH FBC ACC 602 AND FBC | | | PL [B] 410.2 IS REQUIRED. | | | | | | 7. PLEASE PROVIDE SANITARY AND WATER RISER DIAGRAM. PER | | | WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | 8. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | | | 9. A SERVICE SINK IS REQUIRED. PER FBC PL TABLE 403.1 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-01-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-01-04 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-12-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2016-12-15 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
PG |
Date |
2016-11-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2016-11-18 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|