Plan Review Details - Permit 16100709
| Plan Review Stops For Permit 16100709 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-11-07 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-11-02 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2016-11-14 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-11-14 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-11-14 |
Time |
09:02 |
Sent To |
M |
|
| Notes |
| 2016-11-14 13:36:38 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | AS PER OWNERS REQUEST SHEETS E1 - E4 REVISIONS ARE NOT | | | GONA BE REVIEWED FOR ELECTRICAL. OWNER WISHES TO USE | | | ORIGINAL PLANS, AS PER FUTURE ELECTRICAL REVISIONS WILL | | | HAVE TO BE SUBMITTED SEPERATELY. | | | ROUTED TO JV (MECHANICAL). |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2016-11-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-17 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-16 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-11-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-09 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-09 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2016-11-09 12:56:23 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | 1. PIPING TO FIRST TEE AT TANKLESS WATER HEATERS SHALL | | | BE 1". PER FBC FGC TABLE 402(5) AND 402.4.1 | | | | | | 2.THE SECTION OF PIPE BETWEEN THE RANGE AND THE POOL | | | HEATER SHALL BE 1". PER FBC FGC TABLE 402(22) AND | | | 402.4.1 | | | | | | 3. THE UNDER GROUND PIPING CAN NOT BE SCH 40 METALLIC | | | THE SLEEVE WOULD NOT BE WATER TIGHT THE WAY IT WOULD BE | | | ASSEMBLED. THE TRAC PIPE PS-11 CAN BE USED WITH NO | | | SLEEVE IF INSTALLED PER MANUFACTURE INSTILLATION GUIDE. | | | PER FBC FG 404.11 | | | | | | 4. THE PE PIPE TO THE FIRE PIT ON POOL DECK CAN NOT RUN | | | UNDER COVERED TERRACE IT SHALL RUN UNDER OPEN WALKWAY | | | BETWEEN TERRACE AND THE GYM. FBC FG 404.17.1 EXCEPTION | | | 3. | | | | | | 5. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-11-18 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-11-18 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2016-11-18 11:45:36 | WINDOWS/OPENINGS SHALL BE ADDED TO SOUTH ELEVATION OF | | | GAZEBO OR GYM. FRIEDERIKE MITTNER 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-11-18 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-10-24 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2016-11-15 18:47:20 | ROUTED TO GEORGE JOHNSON 11/15/2016 - JORGE V. | | 2016-10-25 16:00:29 | R23 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2016-11-15 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-11-15 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-11-15 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-11-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-17 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-16 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-11-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-09 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-08 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2016-11-09 12:37:54 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. FLOOR DRAIN AT KIT ISLAND SINK IS NOT SHOWN ON RISER | | | DIAGRAM PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. TRAP PRIMER REQUIRED ON FLOOR DRAINS. PER FBC RES | | | P3201.2 | | | | | | 3. OUTDOOR SHOWERS AND SINKS SHALL HAVE COVERING TO | | | PREVENT STORM WATER INTO SANITARY. WPB ORD. SEC | | | 90-126(B)5 | | | | | | 4. PLANS NOTE GYM SHOWER 124 BUT NO SHOWER IS SHOWN | | | PLEASE CLARIFY. WPB AMEND TO FBC |
|
|
|