| Plan Review Stops For Permit 16100655 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-12-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-02 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-02 |
Time |
07:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-10-31 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-10-31 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2016-10-31 08:00:14 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. GRAB BAR IS TO BE MEASURED TO THE TOP OF THE BAR, | | | FBC 5TH EDITION ACCESSIBILITY 609.4, REVISE DETAILS. | | | | | | 2. FBC 1011.1, EXIT SIGNS TO BE READILY VISIBLE. REVISE | | | PLAN TO ADD AN EXIT SIGN AT THE HALLWAY AT THE REAR OF | | | THE UNIT (CLOSET/ RESTROOM WALL). NOTE THAT THIS ITEM | | | WAS REDLINED BY FIRE. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-12-08 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-12-08 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-12-08 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-11-07 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-11-07 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2016-11-07 09:15:29 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. PLEASE ADD A SHOW WINDOW RECEPTACLE AND SHOW LOAD ON | | | PANEL SCHEDULE. NEC 21-.62 | | | 2. PROVIDE A NOTE TO INDICATE ALL 125V RECEPTACLES | | | WITHIN 6FT OF SINKS TO BE GFCI PROTECTED, A NOTE WILL | | | SUFFICENEC 210.8B | | | 3. ADDRESS MECHANICAL AND FIRE COMMENTS RELATED TO | | | ELECTRICAL. | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-10-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-10-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-10-25 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2016-10-25 15:13:46 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEETS A3 & I2.1 - PROVIDE AN EXIT SIGN/LIGHT AT THE | | | REAR OF THE MAIN FLOOR AREA LEADING INTO BACK RESTROOM | | | AND REAR EXIT DOOR AREA. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-12-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-22 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-19 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2016-12-20 14:40:14 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-08 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-12-08 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-12-08 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-15 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-10-21 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-12-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-22 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-22 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-05 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-05 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2016-12-05 08:18:36 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100655 | | | 12/5/16 | | | | | | 1) AS PREVIOUSLY REQUESTED, REVISE THE VENTILATION | | | CALCULATIONS TO INCLUDE THE REQUIRED EXHAUST. PLEASE | | | ALSO PROVIDE AN AIR BALANCE CALCULATION. | | | | | | 2) INDICATE THE REQUIRED CLEARANCE DISTANCES FOR THE | | | O/A INTAKE AND EXHAUST OUTLET- SEE SECTIONS 401.4 AND | | | 501.3.1. | | | | | | 3) PROVIDE OPENING PROTECTION FOR THE O/A INTAKE PER | | | SECTION 401.5. | | | | | | 4) SUBMIT THE PRODUCT APPROVAL OR NOA FOR THE ROOF | | | STAND PER RULE 9N-3 FLORIDA DEPT. OF COMMUNITY AFFAIRS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-31 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-31 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2016-10-31 09:08:31 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100665 | | | 10/31/16 | | | | | | 1) BARBER SHOPS ARE REQUIRED TO HAVE AN EXHAUST SYSTEM | | | WITH A DESIGN CAPACITY OF 0.5 CFM PER SF. - REFER TO | | | TABLE 403.3. PLEASE REVISE THE PLAN AND THE VENTILATION | | | CALCULATIONS. | | | | | | 2) PLEASE CLARIFY WHY AN EXHAUST FAN IS BEING INSTALLED | | | IN THE EMPLOYEE LOUNGE AND PROVIDE A SIZING | | | CALCULATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-15 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-15 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|