Plan Review Details - Permit 16100639
Plan Review Stops For Permit 16100639
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-10-31 Cont ID  
Sent By shill Date 2016-10-31 Time 08:40 Rev Time 0.00
Received By shill Date 2016-10-31 Time 08:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-11-28 Cont ID  
Sent By mvaldes Date 2016-11-28 Time 14:45 Rev Time 0.00
Received By mvaldes Date 2016-11-28 Time 14:34 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-11-07 Cont ID  
Sent By mvaldes Date 2016-11-07 Time 13:20 Rev Time 0.00
Received By mvaldes Date 2016-11-07 Time 11:13 Sent To  
Notes
2016-11-07 13:35:00REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO
  
 1] ADD A EXIT LIGHT WITH THE PROPER DIRECTIONAL ARROW
 BY THE HALLWAY IN THE SOUTH EXIT DOOR. (RED-LINED ON
 PLANS BY FIRE MARSHALL)

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-10-26 Cont ID  
Sent By pleduc Date 2016-10-26 Time   Rev Time 0.00
Received By pleduc Date 2016-10-26 Time 14:53 Sent To  
Notes
2016-10-26 15:33:25THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) SHEET A.06 - PLEASE ENSURE THAT THE REAR SIDE DOUBLE
 DOOR EXIT LEADS TO A CLEAR AND OBVIOUS PUBLIC WAY. A
 FIRE INSPECTOR SHALL REVIEW AND CONFIRM ON FINAL FIRE
 INSPECTION.
  
  
 2) SHEET E 1 - IT APPEARS THAT THE SIDE REAR EXIT SIGN
 IS NOT VISIBLE FROM THE MIDDLE AREAS OF THE PROPOSED
 FLOOR LAYOUT. ADD AN EXIT SIGN AT THE MIDDLE REAR WALL
 AREA DIRECTING TOWARDS THE REAR SIDE EXIT.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2016-11-08 Cont ID  
Sent By gjohnson Date 2016-11-08 Time 14:37 Rev Time 0.00
Received By gjohnson Date 2016-11-08 Time 14:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-28 Cont ID  
Sent By ccole Date 2016-11-28 Time 17:06 Rev Time 0.00
Received By ccole Date 2016-11-21 Time 15:24 Sent To  
Notes
2016-11-21 15:25:03RESUB ROUTED TO MVALDES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-08 Cont ID  
Sent By gjohnson Date 2016-11-08 Time 14:38 Rev Time 0.00
Received By gjohnson Date 2016-10-21 Time 13:34 Sent To  
Notes
2016-10-24 13:34:26B26

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-11-28 Cont ID  
Sent By ccole Date 2016-11-28 Time 17:04 Rev Time 0.00
Received By ccole Date 2016-11-28 Time 17:04 Sent To  
Notes
2016-11-28 17:06:08MECHANICAL PROVISO
 11/28/16
  
 1) TEST AND BALANCE REPORT REQUIRED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-31 Cont ID  
Sent By ccole Date 2016-10-31 Time 11:38 Rev Time 0.00
Received By ccole Date 2016-10-31 Time 09:41 Sent To  
Notes
2016-10-31 11:47:061ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES
 PERMIT #16100639
 10/31/16
  
 1) M-1: REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING
 CODE AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR
 ALL ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL.
 PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED CFMS OF OUTDOOR AIR.
  
 2) M-2: PROVIDE THE WIND LOAD DESIGN CRITERIA AND
 DESIGN PRESSURES ON THE PLAN- SEE SECTION 1609 FBC-14.
  
 3) ADVISORY: IN REGARD TO THE SEPARATELY PERMITTED
 KITCHEN HOOD AND EXHAUST SYSTEM REFER TO SECTION
 508.1.1 FBC-14 MECHANICAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-11-08 Cont ID  
Sent By gjohnson Date 2016-11-08 Time 14:37 Rev Time 0.00
Received By gjohnson Date 2016-11-08 Time 13:22 Sent To  
Notes
***NONE***