| Plan Review Stops For Permit 16100639 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-10-31 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-10-31 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-11-28 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-11-28 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-11-28 |
Time |
14:34 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-11-07 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-11-07 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2016-11-07 13:35:00 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | PASSED WITH THE FOLLOWING PROVISO | | | | | | 1] ADD A EXIT LIGHT WITH THE PROPER DIRECTIONAL ARROW | | | BY THE HALLWAY IN THE SOUTH EXIT DOOR. (RED-LINED ON | | | PLANS BY FIRE MARSHALL) |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-10-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-10-26 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2016-10-26 15:33:25 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEET A.06 - PLEASE ENSURE THAT THE REAR SIDE DOUBLE | | | DOOR EXIT LEADS TO A CLEAR AND OBVIOUS PUBLIC WAY. A | | | FIRE INSPECTOR SHALL REVIEW AND CONFIRM ON FINAL FIRE | | | INSPECTION. | | | | | | | | | 2) SHEET E 1 - IT APPEARS THAT THE SIDE REAR EXIT SIGN | | | IS NOT VISIBLE FROM THE MIDDLE AREAS OF THE PROPOSED | | | FLOOR LAYOUT. ADD AN EXIT SIGN AT THE MIDDLE REAR WALL | | | AREA DIRECTING TOWARDS THE REAR SIDE EXIT. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2016-11-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-08 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-08 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-11-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-28 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-21 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2016-11-21 15:25:03 | RESUB ROUTED TO MVALDES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-08 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-10-21 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-11-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-28 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-28 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2016-11-28 17:06:08 | MECHANICAL PROVISO | | | 11/28/16 | | | | | | 1) TEST AND BALANCE REPORT REQUIRED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-31 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-31 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2016-10-31 11:47:06 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | | PERMIT #16100639 | | | 10/31/16 | | | | | | 1) M-1: REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING | | | CODE AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR | | | ALL ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL. | | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | | PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 2) M-2: PROVIDE THE WIND LOAD DESIGN CRITERIA AND | | | DESIGN PRESSURES ON THE PLAN- SEE SECTION 1609 FBC-14. | | | | | | 3) ADVISORY: IN REGARD TO THE SEPARATELY PERMITTED | | | KITCHEN HOOD AND EXHAUST SYSTEM REFER TO SECTION | | | 508.1.1 FBC-14 MECHANICAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-08 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-08 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|