Plan Review Details - Permit 16100393
| Plan Review Stops For Permit 16100393 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-11-07 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-11-07 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2016-11-07 10:49:41 | 3RD REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | | | PROVISIONALLY APPROVED. THE RAS CALCULATIONS ARE | | | ERRONEOUS. I EXPLAINED TO THE OWNER NEW CALCULATIONS | | | AND FASTENING REQUIREMENTS OF LESS THAN 9" OC BY THE | | | EOR ARE TO BE SUPPLIED TO THE INSPECTOR FOR THE FILE | | | FOR ZONES 3 & PERHAPS ZONE 2. THE EOR COULD NOT BE | | | REACHED. THE OWNER INDICATED THE ROOF IS LEAKING AND | | | THIS IS AN EMERGENCY. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-11-01 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-11-01 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2016-11-01 17:52:37 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SPECIFY WHICH TYPE OF ROOF WILL BE ROOFED OVER AND | | | WHICH WILL BE REMOVED TO THE ROOF DECK. FBC 107.2.1 THE | | | DESCRIPTION OF WORK ON THE PERMIT APPLICATION STATES | | | THAT THE SHINGLES WILL BE A RECOVER (ROOF OVER). THIS | | | NEEDS TO BE CROSSED OUT, BY THE APPLICANT, AND CHANGED | | | TO "REROOF" ON THE APPLICATION. FBC 107.2.1 | | | | | | 2) THE SIGNED AND SEALED RAS 117 CALCULATIONS THAT WERE | | | SUBMITTED FOR THE FLAT ROOF CONTAINS SEVERAL ERRORS. | | | THE FASTENER SPACING OF THE TWO ROWS IN THE FIELD IS 9" | | | O.C. FOR THE E(2) SYSTEM WITH THE MAXIMUM DESIGN | | | PRESSURE OF -60 PSF ON PAGE 28 OF NOA NO. 14-1030.02. | | | THIS ERROR CAUSES ALL OF YOUR NAILING REQUIREMENTS TO | | | ALSO BE IN ERROR. PLEASE CORRECT. FBC 107.2.1.3 | | | | | | 3) THE VALUATION FOR THE WORK HAS BEEN INCREASED FROM | | | $8,250.00 TO $11,860 BASED ON THE LATEST MARSHALL | | | VALUATION DATA. FBC 109.3 | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-17 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-17 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2016-10-17 18:29:53 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE DESCRIPTION OF WORK ON THE APPLICATION IS NOT | | | CLEAR. PROVIDE TWO COPIES OF A ROOF PLAN WITH THE | | | SQUARE FOOT AREA OF EACH ROOF SECTION (SLOPED AND | | | FLAT). SPECIFY THE AREAS THAT ARE SLOPED AND THE AREAS | | | THAT ARE FLAT. FBC 107.2.1 | | | | | | 2) SPECIFY WHICH TYPE OF ROOF WILL BE ROOFED OVER AND | | | WHICH WILL BE REMOVED TO THE ROOF DECK. FBC 107.2.1 | | | | | | 3) SUBMIT TWO SETS OF PRODUCT APPROVALS THAT IS | | | APPROVED FOR A RECOVER OF THE EXISTING ROOFING | | | MATERIALS. DCA RULE 9N-3 | | | | | | 4) SUBMIT TWO SETS OF SIGNED AND SEALED RAS 117 | | | CALCULATIONS FOR ENHANCED FASTENING OF THE BASE SHEET | | | AS REQUIRED BY LIMITATION NUMBER 7 OF PRODUCT APPROVAL | | | NOA NO.14-1030.02 FOR THE FLAT ROOF. FBC 107.2.1.3 | | | | | | 5) THE VALUATION FOR THE WORK WILL BE CHECKED WHEN THE | | | SQUARE FEET AREAS FOR EACH OF THE DIFFERENT ROOFING | | | PERMITS ARE PROVIDED. FBC 109.3 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-11-01 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-31 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2016-11-01 13:10:41 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-10-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-17 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-17 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2016-10-17 14:32:34 | RMCDOUGAL'S DESK |
|
|
|