Plan Review Details - Permit 16100301
Plan Review Stops For Permit 16100301
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-12-05 Cont ID  
Sent By jwitmer Date 2016-12-05 Time 07:13 Rev Time 0.00
Received By jwitmer Date 2016-12-05 Time 06:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-25 Cont ID  
Sent By jwitmer Date 2016-10-25 Time 08:43 Rev Time 0.00
Received By jwitmer Date 2016-10-25 Time 08:15 Sent To  
Notes
2016-10-25 08:43:12BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16100301
 ADD: 603 VILLAGE BLVD. # 208
 CONT: RYBEK CONSTRUCTION INC.
 TEL: 561-762-7456
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. OCT. 25/ 2016
 ACTION: DENIED
  
 1) SHEET A-1 SHOWS A NON-COMPLIANT ACCESSIBLE RESTROOM.
 THE PLANS INDICATE THERE IS AN ACCESSIBLE RESTROOM AND
 DRINKING FOUNTAIN IN THE COMMON AREAS. THE PLANS WILL
 NEED TO SHOW EITHER THE LOCATION OF THE COMMON AREA
 RESTROOMS AND DRINKING FOUNTAIN, PROVIDE THE LENGTH OF
 TRAVEL TO THESE FACILITIES AND WHAT FLOOR THEY ARE
 LOCATE OR PROVIDE WHERE 20% OF THE CONTRACT VALUE OF
 $4,400.00 WHERE ACCESSIBLE UP GRADES WILL BE COMPLETED.
 IF THE ACCESSIBLE UP GRADES ARE CHOSEN PLEASE PROVIDE A
 ITEMIZED LIST SHOWING COMPLIANCE WITH:
 2014 FBC-ACCESSIBILITY CODE 202.4.1 DISPROPORTIONATE
 COST. ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-12-07 Cont ID  
Sent By mvaldes Date 2016-12-07 Time 08:27 Rev Time 0.00
Received By mvaldes Date 2016-12-07 Time 08:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-10-26 Cont ID  
Sent By mvaldes Date 2016-10-26 Time 11:30 Rev Time 0.00
Received By mvaldes Date 2016-10-26 Time 10:30 Sent To  
Notes
2016-10-26 11:25:25JOB PERMIT NUMBER: 16100301
 JOB ADDRESS: 603 VILLAGE BLVD SUITE #208
 WEST PALM BEACH FLORIDA
 DATE: OCTOBER 26, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 - THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC
 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA
 BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH
 AMENDMENTS. BELOW IS A LIST OF THE ITEMS NOTED.
  
 1] PROVIDE EMERGENCY LIGHTING IN THE FLOOR SPACE AREA
 WHERE THE NEW A/C CLOSET IS LOCATED. FBC-1006.1
 ILLUMINATION REQUIRED.
  
 2] EXITS & EMERGENCY LIGHTS SHALL BE FED BY THE LOCAL
 LIGHTING CIRCUIT IN THAT AREA. NEC 700.12(F)(4) SHOW
 COMPLIANCE.
  
 3] CLARIFY IF RECEPTACLE OUTLETS BY THE BREAKROOM SINK
 HAVE GFCI PROTECTION PER NEC 210.8(B)(5)
  
 4] ADD A NOTE FOR QUICK-BREAK DISCONNECTS IN
 FLUORESCENT FIXTURES IN ACCORDANCE WITH NEC 410.130(G)
  
 - PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER
 RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES
 WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER
 QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME
 DIRECTLY.
  
 1ST REVIEW, FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-11-22 Cont ID  
Sent By pleduc Date 2016-11-22 Time   Rev Time 0.00
Received By pleduc Date 2016-11-22 Time 15:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-10-18 Cont ID  
Sent By pleduc Date 2016-10-18 Time   Rev Time 0.00
Received By pleduc Date 2016-10-18 Time 09:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-14 Cont ID  
Sent By ccole Date 2017-04-14 Time 14:26 Rev Time 0.00
Received By ccole Date 2017-04-13 Time 10:48 Sent To  
Notes
2017-04-14 10:48:25RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-07 Cont ID  
Sent By mvaldes Date 2016-12-07 Time 08:30 Rev Time 0.00
Received By mvaldes Date 2016-11-17 Time 11:13 Sent To  
Notes
2016-11-18 11:13:15B16

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-03 Cont ID  
Sent By gjohnson Date 2016-11-03 Time 15:47 Rev Time 0.00
Received By gjohnson Date 2016-10-13 Time 15:09 Sent To  
Notes
2016-10-14 15:10:35B12

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-04-14 Cont ID  
Sent By ccole Date 2017-04-14 Time 14:26 Rev Time 0.00
Received By ccole Date 2017-04-14 Time 14:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-11-29 Cont ID  
Sent By ccole Date 2016-11-29 Time 17:59 Rev Time 0.00
Received By ccole Date 2016-11-29 Time 17:59 Sent To  
Notes
2016-11-29 18:01:162ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16100301
 11/29/16
  
 1) COMMENTS FORM THE 1ST REVIEW STILL EXIST. NO
 MECHANICAL PLANS HAVE BEEN SUBMITTED. SEE 1ST REVIEW
 COMMENTS PRINTED BELOW.
  
 1ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16100301
 10/19/16
  
 1) PROVIDE A DUCT LAYOUT PLAN FOR THE RELOCATED AIR
 HANDLER- SHOW TYPES AND SIZES OF SUPPLY AND RETURN
 DUCTS AND POINTS OF CONNECTIONS TO EXISTING DUCTWORK.
 INDICATE LOCATIONS OF FIRE OR FIRE/SMOKE DAMPERS AND
 PROVIDE INSTALLATION DETAILS.
  
 2) PROVIDE AN EQUIPMENT SCHEDULE FOR THE RELOCATED AIR
 HANDLER- MAKE AND MODEL, COOLING AND HEATING CAPACITY.
  
 3) REFER TO SECTION C403.2.7.2 FBC-14 ENERGY
 CONSERVATION AND INDICATE THE TYPE OF DOOR TO BE
 INSTALLED AT THE AC CLOSET. PLEASE NOTE IF THE DOOR IS
 LOUVERED FOR RETURN AIR IT MUST BE MADE OF
 NON-COMBUSTIBLE MATERIAL.
  
 4) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE
 AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL
 ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL.
 PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED CFMS OF OUTDOOR AIR.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-19 Cont ID  
Sent By ccole Date 2016-10-19 Time 13:24 Rev Time 0.00
Received By ccole Date 2016-10-19 Time 13:24 Sent To  
Notes
2016-10-19 13:50:491ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16100301
 10/19/16
  
 1) PROVIDE A DUCT LAYOUT PLAN FOR THE RELOCATED AIR
 HANDLER- SHOW TYPES AND SIZES OF SUPPLY AND RETURN
 DUCTS AND POINTS OF CONNECTIONS TO EXISTING DUCTWORK.
 INDICATE LOCATIONS OF FIRE OR FIRE/SMOKE DAMPERS AND
 PROVIDE INSTALLATION DETAILS.
  
 2) PROVIDE AN EQUIPMENT SCHEDULE FOR THE RELOCATED AIR
 HANDLER- MAKE AND MODEL, COOLING AND HEATING CAPACITY.
  
 3) REFER TO SECTION C403.2.7.2 FBC-14 ENERGY
 CONSERVATION AND INDICATE THE TYPE OF DOOR TO BE
 INSTALLED AT THE AC CLOSET. PLEASE NOTE IF THE DOOR IS
 LOUVERED FOR RETURN AIR IT MUST BE MADE OF
 NON-COMBUSTIBLE MATERIAL.
  
 4) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE
 AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL
 ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL.
 PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED CFMS OF OUTDOOR AIR.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-12-06 Cont ID  
Sent By gjohnson Date 2016-12-06 Time 10:47 Rev Time 0.00
Received By gjohnson Date 2016-12-06 Time 10:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-11-03 Cont ID  
Sent By gjohnson Date 2016-11-03 Time 15:47 Rev Time 0.00
Received By gjohnson Date 2016-11-03 Time 12:58 Sent To  
Notes
***NONE***