| Plan Review Stops For Permit 16100277 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-11-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-09 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-09 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2016-11-09 07:30:22 | ****PROVISO**** | | | ****REVISION REQUIRED**** | | | ****ISSUED AT CONTRACTOR'S RISK*** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | THE SOUTH EXTERIOR ENTRY DOOR ON THE FLOOR PLAN (PERMIT | | | 16100277) AND THE NORTH INTERIOR SECURITY VESTIBULE | | | DOORS SHOWN ON THE FLOOR PLAN AS "EXISTING" HAVE DOOR | | | SWING CONFIGURATION WHICH ARE NOT CONSISTENT WITH THE | | | PERMIT ISSUED FOR THIS SCOPE OF WORK, EXPIRED ENTRY | | | SECURITY VESTIBULE PERMIT 14020726, NEW "FINAL | | | INSPECTION ONLY" PERMIT 16110426. | | | | | | PRIOR TO FINAL INSPECTION, THE TWO PLANS SHOULD | | | CORRELATE AND SHOULD MATCH THE EXISTING CONDITIONS. A | | | REVISION IS REQUIRED. | | | | | | THIS PERMIT IS ISSUED AT CONTRACTOR'S RISK. THE NEW | | | PROPOSED (NOT YET SUBMITTED FOR PLAN REVIEW) | | | CONFIGURATION IS TO BE SUBMITTED AND APPROVED AS A | | | REVISION (TO 16110426) PRIOR TO FINAL INSPECTION. OR, | | | THE INSTALLATION CAN BE MODIFIED TO BE CONSISTENT WITH | | | THE ISSUED PERMIT. IN THAT CASE, THE "FINAL INSPECTION | | | ONLY" PERMIT 16110426 SHOULD BE MODIFIED TO A "REISSUE" | | | PERMIT AND THE FLOOR PLAN FOR RENOVATION PERMIT | | | 16100277 REVISED TO BE CONSISTENT. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-11-03 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-11-03 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2016-11-03 16:37:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | 1. THE SECURITY VESTIBULE PERMIT IS EXPIRED. THE PLAN | | | SHOWS THIS AS EXISTING, BUT IT IS EXISTING (FOR | | | BUILDING CODE PURPOSES) ONLY IF IT WAS LEGALLY | | | PERMITTED, CONSTRUCTED AS PERMITTED, AND FINALED. THE | | | PLAN SHOWS THAT THE CONSTRUCTION IS NOT CONSISTENT WITH | | | THE ISSUED PERMIT, DOES NOT APPEAR TO COMPLY WITH | | | ACCESSIBILITY MANEUVERING CLEARANCE REQUIREMENT ON THE | | | PULL SIDE, AND NO BUILDING INSPECTIONS WERE SCHEDULED | | | (ONLY FIRE INSPECTIONS). | | | | | | EITHER APPLY FOR A SEPARATE PERMIT FOR THE VESTIBULE | | | WORK, OR INCORPORATE THAT WORK INTO THIS PERMIT. SEE | | | EXPIRED PERMIT 14020726. YOU MAY OBTAIN A COPY OF THE | | | PLAN FOR THAT PERMIT BY SUBMITTING A REQUEST TO | | | [email protected]. | | | | | | 2ND REVIEW, THE EXPIRED PERMIT HAS NOT BEEN ADDRESSED. | | | THE WORK INSTALLED IS NOT CONSISTENT WITH THE ISSUED | | | PERMIT. C M FREEMAN IS TO SUBMIT APPLICATION FOR A | | | PERMIT FOR THAT WORK. PLEASE ADVISE WHEN THIS HAS BEEN | | | DONE AND THE BUILDING REVIEW WILL BE PASSED (PENDING | | | ITEM 3). | | | | | | 2. OK | | | | | | 3. SHEET A4.1 REFERS TO FBC 2007 IN MORE THAN ONE | | | LOCATION, REVISE. | | | | | | THIS HAS BEEN REVISED TO FBC 2012, ALSO REFERS TO FBC | | | ADA 2012, THE CODE IN EFFECT IS FBC 5TH EDITION OR FBC | | | 2014. | | | | | | THIS MAY BE A PROVISO ITEM UPON REQUEST. | | | | | | 4, 5, 6. OK | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-10-21 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-10-21 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2016-10-21 12:26:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. THE SECURITY VESTIBULE PERMIT IS EXPIRED. THE PLAN | | | SHOWS THIS AS EXISTING, BUT IT IS EXISTING (FOR | | | BUILDING CODE PURPOSES) ONLY IF IT WAS LEGALLY | | | PERMITTED, CONSTRUCTED AS PERMITTED, AND FINALED. THE | | | PLAN SHOWS THAT THE CONSTRUCTION IS NOT CONSISTENT WITH | | | THE ISSUED PERMIT, DOES NOT APPEAR TO COMPLY WITH | | | ACCESSIBILITY MANEUVERING CLEARANCE REQUIREMENT ON THE | | | PULL SIDE, AND NO BUILDING INSPECTIONS WERE SCHEDULED | | | (ONLY FIRE INSPECTIONS). | | | | | | EITHER APPLY FOR A SEPARATE PERMIT FOR THE VESTIBULE | | | WORK, OR INCORPORATE THAT WORK INTO THIS PERMIT. SEE | | | EXPIRED PERMIT 14020726. YOU MAY OBTAIN A COPY OF THE | | | PLAN FOR THAT PERMIT BY SUBMITTING A REQUEST TO | | | [email protected]. | | | | | | 2. UNNUMBERED DOOR WHICH SERVES THE BACK AREA, SHOW THE | | | 18IN PULL SIDE MANEUVERING CLEARANCE FBC 5TH EDITION | | | ACCESSIBILITY 404.2.4.1. | | | | | | 3. SHEET A4.1 REFERS TO FBC 2007 IN MORE THAN ONE | | | LOCATION, REVISE. | | | | | | 4. PROVIDE THE PRODUCT APPROVAL FOR THE NEW DRIVE UP | | | ATM. PRODUCT APPROVAL IS TO BE REVIEWED BY DESIGNER OF | | | RECORD, FBC 107. | | | | | | 5. PLAN LACKS WIND DESIGN CRITERIA, FBC 1603.4.1., ADD | | | TO PLAN. | | | | | | 6. SEE PLUMBING COMMENTS AND REVISE PLAN ACCORDINGLY. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-11-07 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-11-07 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-10-19 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-10-19 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-19 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2016-10-19 09:51:10 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE | | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | | PERMITS AND DATA CUT SHEET SUBMITTALS FOR ALL LOW | | | VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED TO FIRE | | | ALARM, ACCESS CONTROLS, CCTV, PHONE AND DATA, WIRELESS | | | SYSTEMS,ETC. A NOTE WILL SUFFICE. | | | 2. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO | | | INDICATE NEC 110.24- AVAILABLE FAULT CURRENT- FIELD | | | MARKINGS; SEE VERBIAGE IN CODE. | | | 3. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO | | | INDICATE NEC 110.16- ARC FLASH WARNING; SEE VERBIAGE IN | | | CODE. | | | 4. PERE NEC 110.15- PROVIDE NOTE FOR HIGH LEG MARKINGS | | | REQUIREMENTS AT THE SERVICE AND PANELBOARDS. SEE NEC | | | 408.2F1 | | | 5. PER FBC-EC 405.7- A MINIMUM OF 50% OF ALL | | | RECEPTACLES SHALL BE AUTOMATICALLY CONTROLLED FOR | | | OFFICE AREAS. SHOW COMPLIANCE | | | 6. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | | THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-11-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-11-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-11-03 |
Time |
12:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-10-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-10-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-10-18 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-12-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-01 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-18 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2016-11-21 14:43:38 | RESUB ROUTED TO VPEREZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-11-07 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-11-07 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-10-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-10-21 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-10-13 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-12-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-28 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-28 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-11-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-11-04 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-04 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2016-11-04 10:32:11 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100277 | | | 11/4/16 | | | | | | 1) SUBMIT AHRI CERTIFICATES FOR THE AC SYSTEMS TO | | | VERIFY THAT THE REPLACED AIR HANDLERS MATCH THE | | | EXISTING CONDENSERS | | | | | | 2) THE 18X10 AND 12" TRANSFER DUCTS AT THE BREAKROOM | | | AND BOLD SPACE ARE UNDERSIZED PER SECTION 601.5 | | | EXCEPTION 1. PLEASE PROVIDE THE TRANSFER AND RETURN | | | GRILL SIZES ON THE PLANS. | | | | | | 3) INDICATE THE TYPE OF LOUVERED DOORS THAT ARE | | | ENCLOSING THE MECHANICAL CLOSET AND CONVEYING RETURN | | | AIR. PLEASE NOTE THAT THE DOORS MUST BE NON-COMBUSTIBLE | | | PER SECTION C403.2.7.2 FBC-14 ENERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-19 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-19 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2016-10-19 15:52:29 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100277 | | | 10/19/16 | | | | | | 1) CLARIFY HOW THE O/A MOTORIZED DAMPER FOR AHU-1 & | | | AHU-2 WILL FUNCTION INDIVDUALLY FOR EACH SYSTEM. | | | | | | 2) LEVEL-2 ALTERATIONS SHALL BE IN COMPLIANCE WITH THE | | | CURRENT CODES IN EFFECT- SEE SECTION 801.3 FBC-14 | | | EXISTING BUILDING CODE. PROVIDE DUCT SMOKE DETECTORS IN | | | THE RETURN AIR SYSTEMS OF THE REPLACED AIR HANDLERS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-11-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-07 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-07 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-10-21 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-10-21 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2016-10-21 10:28:35 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE GRAB BARS SHALL BE MEASURED FROM THE TOP OF THE | | | GRIPPING SURFACE TO FINISH FLOOR AND BE MIN 33" MAX | | | 36". PER FBC ACC 609.4 | | | | | | 2. TH TOILET PAPER DISPENSER SHALL COMPLY WITH FBC ACC | | | 604.7 DISPENSERS. | | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE | | | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 | | | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND | | | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL | | | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES | | | NOT ALLOW CONTINUOUS PAPER FLOW. | | | | | | 3. LAVATORY'S SHALL BE SUPPLIED WITH TEMPERED WATER. | | | PER FBC PL 416.5 TEMPERED WATER FOR PUBLIC HAND-WASHING | | | FACILITIES. | | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3. | | | | | | 4. SHT. P-1.1 THE FLOOR PLAN DID NOT COPY WELL IT IS | | | VERY LIGHT AND SOME OF THE WALLS AND FIXTURES CAN NOT | | | BE SEEN PLEASE PROVIDE A DARKER COPY. PER WPB AMEND TO | | | FBC 107.2.1.4 | | | | | | 5. A SERVICE SINK IS REQUIRED PER FBC PL TABLE 403.1 |
|
|