| Plan Review Stops For Permit 16100266 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-02-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-02 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-02-02 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-01-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-01-19 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-01-19 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2017-01-19 14:46:49 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16100266 | | | ADD: 2471 OKEECHOBEE BLVD. SUITE # 7 | | | CONT: ARGOS BUILDERS LLC | | | CONTACT: RAMON CASTRO | | | TEL: 407-877-3009 EXT 106 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: THURS. JAN. 19/ 2017 | | | ACTION: DENIED | | | | | | 1-3) COMPLIED. | | | | | | 4)3RD SEMI-COMPLIED. 2014 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31(D) ROOFING PRODUCTS AND ASSEMBLIES/ ROOF TOP CURBS. | | | SEE COMMENT # 6. | | | | | | | | | 5) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 6)3RD REQUEST. | | | 4X FEE NOTICE!!!!! | | | FLORIDA STATUTE 553.80(2)(B) WITH RESPECT TO EVALUATION | | | OF DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL | | | GOVERNMENT FINDS IT NECESSARY, IN ORDER TO ENFORCE | | | COMPLIANCE WITH THE FLORIDA BUILDING CODE AND ISSUE A | | | PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY THE CODE | | | THREE OR MORE TIMES FOR FAILURE TO CORRECT A CODE | | | VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH | | | REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE | | | PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | SUBMITTED WERE COPIES OF SIGNED AND SEALED CARRIER | | | MOUNTING OF THE RTU TO THE ROOF TOP CURB. PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY | | | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN | | | PROFESSIONAL AFFIXED TO THE DOCUMENT. F. S. 471.025 | | | THE SUBMITTED CARRIER DOCUMENTS SHOWS THE PROCEDURE OF | | | MOUNTING THE RTU TO THE CARRIER CURB BUT THERE IS NO | | | DOCUMENTS SHOWING HOW THE CURB IS TO BE SECURED TO THE | | | ROOF FRAMING SYSTEM TO BE SECURED TO THE MWFRS (MAIN | | | WIND FORCE RESISTING SYSTEM. 2014 FBC-B 1604.4 | | | ANALYSIS. 2014 FBC-M- 301.15 WIND RESISTANCE | | | 1ST ROUND OF COMMENTS. SHEET M1 NOTE # 1 INDICATES TO | | | REPLACE ALL ROOF TOP UNITS. SHEET M3 SHOWS A ROOF TOP | | | A/C CURB BUT NO INFORMATION AS TO THE ATTACHING OF THE | | | CURB TO THE ROOF FRAMING PART OF THE (MWFRS) MAIN WIND | | | FORCE RESISTING SYSTEM. PLEASE PROVIDE ANCHORING OF THE | | | CURB AND RTU TO RESIST THE MOMENT OF OVERTURNING. | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-09 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-09 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2016-12-09 15:38:17 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16100266 | | | ADD: 2471 OKEECHOBEE BLVD. SUITE # 7 | | | CONT: TBD/ TO BE DETERMINED | | | TEL: NO CONTACT INFO | | | E-MAIL: NO CONTACT INFO | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: FRI. DEC. 09/ 2016 | | | ACTION: DENIED | | | | | | 1-2) COMPLIED. | | | | | | 3) SEMI-COMPLIED. SHEET A-7.3 DETAIL 2 SHOWS A 42 INCH | | | GUARDRAIL/ HANDRAIL SYSTEM. PLEASE NOTE THERE IS NO | | | HANDRAIL SHOWN IN THE DETAIL. THE 2014 FBC-B SECTION | | | 1010.9 REQUIRES HANDRAILS ON BOTH SIDES WHEN THE RISE | | | IS GREATER THAN OF THE RAMP IS GREATER THAN 6 INCHES. | | | SECTION 1012.2 THE HANDRAIL HEIGHT IS BETWEEN 34 AND 38 | | | INCHES. | | | 1012.6 HANDRAIL EXTENSIONS. HANDRAILS SHALL RETURN TO A | | | WALL, GUARD OR THE WALKING SURFACE OR SHALL BE | | | CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT | | | OR RAMP RUN. AT RAMPS WHERE HANDRAILS ARE NOT | | | CONTINUOUS BETWEEN RUNS, THE HANDRAILS SHALL EXTEND | | | HORIZONTALLY ABOVE THE LANDING 12 INCHES (305 MM) | | | MINIMUM BEYOND THE TOP AND BOTTOM OF RAMP RUNS. THE | | | EXTENSIONS OF HANDRAILS SHALL BE IN THE SAME DIRECTION | | | OF THE STAIR FLIGHTS AT STAIRWAYS AND THE RAMP RUNS AT | | | RAMPS. | | | 1ST ROUND COMMENTS. SHEET A-7.0 SHOWS A NEW SIDE DOOR | | | AND ACCESS RAMP. SHEET A-7.3 DETAIL A CUT SECTION | | | THROUGH THE LENGTH OF THE RAMP. THE PLANS DO NOT | | | PROVIDE THE WIDTH OF THE RAMP NOR INDICATE A TURNING | | | RADIUS INCOMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE | | | 405.7.4 CHANGE IN DIRECTION. | | | | | | 4) SEMI-COMPLIED. 2014 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS . | | | CECO APPROVAL FROM UL IS AN OUT OF DATE 2006 REPORT, | | | AND NO INSTALLATION INSTRUCTIONS FOR INSTALLATION WERE | | | PROVIDE WITH THE REPORT. | | | | | | (C) PANEL WALLS: STOREFRONTS WINDOW & DOOR COMPLIED. | | | | | | (D) ROOFING PRODUCTS AND ASSEMBLIES/ ROOF TOP CURBS/ | | | ROOF TOP EXHAUST FANS. SEE COMMENT # 6. | | | | | | | | | 5) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 6) 2ND REQUEST. SUBMITTED WERE COPIES OF SIGNED AND | | | SEALED CARRIER MOUNTING OF THE RTU TO THE ROOF TOP | | | CURB. PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. F. S. | | | 471.025 | | | THE SUBMITTED CARRIER DOCUMENTS SHOWS THE PROCEDURE OF | | | MOUNTING THE RTU TO THE CARRIER CURB BUT THERE IS NO | | | DOCUMENTS SHOWING HOW THE CURB IS TO BE SECURED TO THE | | | ROOF FRAMING SYSTEM TO BE SECURED TO THE MWFRS (MAIN | | | WIND FORCE RESISTING SYSTEM. 2014 FBC-B 1604.4 | | | ANALYSIS. 2014 FBC-M- 301.15 WIND RESISTANCE | | | 1ST ROUND OF COMMENTS. SHEET M1 NOTE # 1 INDICATES TO | | | REPLACE ALL ROOF TOP UNITS. SHEET M3 SHOWS A ROOF TOP | | | A/C CURB BUT NO INFORMATION AS TO THE ATTACHING OF THE | | | CURB TO THE ROOF FRAMING PART OF THE (MWFRS) MAIN WIND | | | FORCE RESISTING SYSTEM. PLEASE PROVIDE ANCHORING OF THE | | | CURB AND RTU TO RESIST THE MOMENT OF OVERTURNING. | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-27 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-27 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2016-10-27 14:10:56 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16100266 | | | ADD: 2471 OKEECHOBEE BLVD. SUITE # 7 | | | CONT: TBD/ TO BE DETERMINED | | | TEL: NO CONTACT INFO | | | E-MAIL: NO CONTACT INFO | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. OCT. 2016 | | | ACTION: DENIED | | | | | | 1) THE COVERSHEET A-0.0 AREA OF TENANT SPACE AND | | | OCCUPANT LOAD VERSES SHEET A-7.0 THE LIFE SAFETY | | | SUMMARY CHART DOES NOT MATCH UP TO SQUARE FOOT AREA NOR | | | OCCUPANT LOADS. 107.2.1.3 DISCREPANCIES IN PLANS, AND | | | 2014 FBC-B TABLE 1004.1.2. | | | | | | 2) SHEET A-7.0 THE WIND DESIGN PRESSURES FOR THE FRONT | | | DOOR APPEAR TO BE IN VULT WHEREAS THE PRESSURES FOR THE | | | NEW SIDE DOOR APPEAR TO BE IN VULT BUT A LITTLE LOW. | | | 2014 COMPONENTS & CLADDING PRESSURES POSITIVE & | | | NEGATIVE TABLE 1609.2(2). | | | 3) SHEET A-7.0 SHOWS A NEW SIDE DOOR AND ACCESS RAMP. | | | SHEET A-7.3 DETAIL A CUT SECTION THROUGH THE LENGTH OF | | | THE RAMP. THE PLANS DO NOT PROVIDE THE WIDTH OF THE | | | RAMP NOR INDICATE A TURNING RADIUS INCOMPLIANCE WITH | | | 2014 FBC-ACCESSIBILITY CODE 405.7.4 CHANGE IN | | | DIRECTION. | | | 4) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES/ ROOF TOP CURBS/ | | | ROOF TOP EXHAUST FANS | | | | | | 5) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 6) SHEET M1 NOTE # 1 INDICATES TO REPLACE ALL ROOF TOP | | | UNITS. SHEET M3 SHOWS A ROOF TOP A/C CURB BUT NO | | | INFORMATION AS TO THE ATTACHING OF THE CURB TO THE ROOF | | | FRAMING PART OF THE (MWFRS) MAIN WIND FORCE RESISTING | | | SYSTEM. PLEASE PROVIDE ANCHORING OF THE CURB AND RTU TO | | | RESIST THE MOMENT OF OVERTURNING. | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-12-08 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-12-08 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-12-08 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2016-12-08 10:48:45 | PROVISO: | | | | | | PLEASE DELETE RECEPTACLE SHOWN ON SHEET E.3.0 CIRCUIT | | | P-12, INITIALY SHOWN ON A WALL THAT HAS BEEN DELETED AT | | | THE REAR EXIT. (AS-BUILTS) | | | | | | VAL PEREZ | | | *6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-10-25 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-10-25 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-25 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2016-10-25 09:15:28 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE | | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | | PERMITS AND DATA CUT SHEET SUBMITTALS FOR ALL LOW | | | VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED TO FIRE | | | ALARM, ACCESS CONTROLS, CCTV, PHONE AND DATA, SIGNAGE, | | | WIRELESS SYSTEMS, ETC. A NOTE WILL SUFFICE. | | | 2. ADD A NOTE TO MAINTAIN ALL ELECTRICAL EQUIPMENT | | | ABOVE THE BASELINE FLOOD ELEVATION PER STATE AND CITY | | | REGULATORY AGENCIES. | | | 3. ADDRESS FIRE COMMENTS RELATED TO ELECTRICAL | | | EMERGENCY LIGHTING. FBC 107.3.5 | | | 4. PLEASE CLARIFY IF EXISTING RISER SHOWN HAS OTHER | | | MAINS, ARE YOU JUST SHOWING THE 400AMP FOR SHOE | | | CARNIVAL STORE? 800AMP TO BE SUFFICIENT TO CARRY ALL | | | LOADS. PLEASE CLARIFY | | | 5. CORRECT TYPO AT PANEL SCHEDULE FOR PANEL P. IS IT A | | | 225MLO OR 100AMPMLO? RISER AND PANEL DO NOT CORRELATE. | | | FBC 107.3.5 | | | 6. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | | THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2017-02-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-02-03 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-02-03 |
Time |
12:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-01-06 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-01-06 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-01-06 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-12-14 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-12-14 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2016-12-14 12:59:16 | 2471 OKEECHOBEE BOULEVARD -SUITE 7 | | | PERMIT #16100266 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-10-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-10-21 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-10-21 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2016-10-21 11:14:08 | 2471 OKEECHOBEE BOULEVARD -SUITE 7 | | | PERMIT #16100266 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PLANS INDICATE AN ADDRESS OF "123 MAIN STREET, ANYTOWN | | | US 12345." | | | | | | SHEET A-2.0: THE OCCUPANT LOAD BREAK DOWN CHART IS | | | INCORRECT. FOR EXAMPLE 7,257 SQ.FT. WOULD RESULT IN AN | | | OCCUPANT LOAD OF 241 (30 SQ.FT. PER PERSON) NOT 139. | | | | | | SHEET E-2.0: ONLY TWO EXIT SIGNS HAVE BEEN PROVIDED FOR | | | THE +7,000 SQ.FT. MERCANTILE FLOOR PLAN. | | | | | | SHEET E-3.0: THE REAR DOOR (DOOR TAG 5) INDICATES THE | | | INSTALLATION OF A DOOR BELL. WHAT IS THE FUNCTION OF | | | THIS BELL? THIS DOOR IS AN EXIT ACCESS DOOR TO THE | | | SECOND BUILDING EXIT AND IS NOT PERMITTED TO BE LOCKED | | | OR RESTRICTED. | | | | | | FIRE ALARM: I BELIEVE THE ENTIRE BUILDING IS PROTECTED | | | BY A FIRE ALARM SYSTEM; HOWEVER, THE PLANS DO NOT SHOW | | | ANY FIRE ALARM NOTIFICATION DEVICES. | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
P |
Date |
2017-02-06 |
|
|
Cont ID |
|
| Sent By |
rsklarew |
Date |
2017-02-06 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
rsklarew |
Date |
2017-01-26 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-01-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-01-19 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-22 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-12-14 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-11-21 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-03 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-10-13 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-10-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-27 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-27 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-02-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-02 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-02 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-01-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-01-04 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-01-04 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2017-01-04 11:13:54 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100266 | | | 1/4/17 | | | | | | 1) THE RTU CURB ENGINEERING SUBMITTAL MUST BEAR AN | | | ORIGINAL SEAL AND SIGNATURE FROM THE CERTIFYING P.E. | | | JOHN BUEROSE- SECTION 61G15- 23.002 FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | 2) THE REVISED ENERGY FORM C402 DOES NOT BEAR THE | | | SIGNATURE OF THE OWNER/AGENT. | | | | | | 3) PROVIDE A SUBMITTAL FOR THE C02 SENSORS. IT APPEARS | | | THAT ONLY ONE SENSOR IS BEING INSTALLED IN THE SPACE | | | WHICH MAY BE INADEQUATE COVERAGE BASED ON SQUARE | | | FOOTAGE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-05 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-05 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2016-12-05 09:14:59 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100266 | | | 12/5/16 | | | | | | 1) COMMENTS #5 & 6 FROM THE 1ST REVIEW STILL EXIST- | | | PLEASE COMPLY. | | | | | | 2) SHEET M1.0: SHOW THE LOCATIONS OF THE CO2 SENSORS ON | | | THE FLOOR PLAN- KEYED NOTE #11. | | | | | | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100266 | | | 10/20/16 | | | | | | 5) M3.0: THE RTU MOUNTING DETAIL DOES NOT INDICATE HOW | | | THE CURB WILL BE ATTACHED TO THE STRUCTURE, AND THERE | | | ARE NO STRUCTURAL DETAILS FOR THAT ATTACHMENT ON THE | | | ARCHITECTURAL OR STRUCTURAL PLAN SHEETS. PLEASE PROVIDE | | | COMPLETE INSTALLATION DETAILS AND COMPLETE DESIGN | | | CRITERIA- EXPOSURE CATEGORY, IMPORTANCE FACTOR, HEIGHT | | | AND ADJUSTMENT COEFFICIENT, AND DESIGN PRESSURES. | | | | | | 6) THE ENERGY COMPLIANCE FORM C402-2014 IS NOT FILLED | | | OUT CORRECTLY. PLEASE REMOVE "SEE ATTACHMENT" AND | | | PROVIDE THE REQUIRED AC AND HEATING SYSTEM DATA IN THE | | | APPROPRIATE BOXES UNDER THE COLUMN TITLED "TYPE", AND | | | THE EFFICIENCY RATINGS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-20 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-20 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2016-10-20 11:56:53 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16100266 | | | 10/20/16 | | | | | | 1) SHEET M2.0: THE OUTSIDE AIR CALCULATIONS SHOW A | | | SHORTAGE OF 198 CFMS FOR THE RTU'S SUPPLYING AIR TO THE | | | SALES AREA. | | | | | | 2) M1.0: PLEASE PROVIDE THE FLEX DUCT SIZES OR RELOCATE | | | THE SCHEDULE ON SHEET M2.0 TO M1.0 | | | | | | 3) M1.0: THE 6" TRANSFER DUCT AT THE VESTIBULE/WORK | | | ROOM IS UNDERSIZED PER SECTION 601.5. | | | | | | 4) PROVIDE A MECHANICAL ROOF PLAN SHOWING ALL REQUIRED | | | CLEARANCE DISTANCE MEASUREMENTS FROM AIR INTAKES TO | | | EXHAUST OUTLETS, AND EQUIPMENT TO ROOF EDGES. A) | | | CLARIFY HOW ACCESS TO THE ROOFTOP MECHANICAL EQUIPMENT | | | IS BEING PROVIDED- SECTION 306.5. | | | | | | 5) M3.0: THE RTU MOUNTING DETAIL DOES NOT INDICATE HOW | | | THE CURB WILL BE ATTACHED TO THE STRUCTURE, AND THERE | | | ARE NO STRUCTURAL DETAILS FOR THAT ATTACHMENT ON THE | | | ARCHITECTURAL OR STRUCTURAL PLAN SHEETS. PLEASE PROVIDE | | | COMPLETE INSTALLATION DETAILS AND COMPLETE DESIGN | | | CRITERIA- EXPOSURE CATEGORY, IMPORTANCE FACTOR, HEIGHT | | | AND ADJUSTMENT COEFFICIENT, AND DESIGN PRESSURES. | | | | | | 6) THE ENERGY COMPLIANCE FORM C402-2014 IS NOT FILLED | | | OUT CORRECTLY. PLEASE REMOVE "SEE ATTACHMENT" AND | | | PROVIDE THE REQUIRED AC AND HEATING SYSTEM DATA IN THE | | | APPROPRIATE BOXES UNDER THE COLUMN TITLED "TYPE", AND | | | THE EFFICIENCY RATINGS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-14 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-14 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-03 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-03 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-01-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-01-12 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-12-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2016-12-01 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
pgrehic |
Date |
2016-10-31 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2016-10-31 |
Time |
|
Sent To |
|
|
| Notes |
|
|