| Plan Review Stops For Permit 16100191 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-12-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-01 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-01 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-26 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-26 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-10-24 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-24 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-10-26 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-10-17 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-12-19 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-12-16 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-12-16 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-11-16 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-11-15 |
Time |
18:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-10-13 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-26 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-26 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-19 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-19 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-12-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-15 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-15 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-11-08 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-11-08 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-11-08 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2016-11-08 12:29:59 | 1) SHT. A8.04 - DETAIL # 10 - THE LOCATION OF OVERFLOW | | | SCUPPERS IN THE PARAPET WALL SHALL COMPLY WITH 2014 FBC | | | SEC. 1503.4.2.1. | | | 2) SHT. A8.03 - VANITY TOP PLAN- THERE IS A NOTE THAT | | | READS "FIRST FLOOR ONLY." CLARIFY. | | | 3) SHT. P5.01 - RISER S/JS - THE RISER SHOWS THE MOP | | | SINKS ON LEVELS #2 & #3 BUT RISER W/JS SHOWS THE WATER | | | SUPPLY TO THE MOP SINKS REMOVED. CLARIFY. | | | 4) SHT. P1.01 - THE HUB DRAIN RECEIVING THE DISCHARGE | | | FROM THE ELEVATOR SUMP SHALL BE EQUIPPED WITH A TRAP | | | PRIMER PER 2014 FPC SEC.1002.4. | | | 5) A2.01 - REMOVE THE BACKGROUND DOTS FROM THE FLOOR | | | PLAN. IT IS VERY DIFFICULT TO SE THE CLEAR FLOOR SPACE | | | FOR THE FIXTURES AND COMPLIANCE WITH THE FHA. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-12-19 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-12-19 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2016-12-19 08:46:25 | 12/19/16 SIGNATURES ON MEP DRAWING ARE OK /GPJ | | 2016-12-16 15:39:34 | PLUMB SIGN. OK 12/16/16 GPJ | | 2016-10-26 16:35:52 | ARCHITECTURAL & STRUCTURAL SHEETS CHECKED FOR | | | SIGNATURES. JW 10/26/2016 & 12/02/2016 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-14 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-11-14 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2016-11-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-11-14 13:34:57 | ** NO CHANGES TO THE APPROVED SITE PLAN OR BUILDING | | | FOOTPRINT. ** | | | | | | ZONING PROVISO: | | | | | | 1.) THE APPLICANT SHALL OBTAIN A ROW PERMIT FROM THE | | | PALM BEACH COUNTY DEPARTMENT OF ENGINEERING AND PUBLIC | | | WORKS FOR THE ACCESS POINT ON SKEES ROAD PRIOR TO FIRST | | | INSPECTION. A COPY OF THE ROW PERMIT SHALL BE SUBMITTED | | | TO THE DEVELOPMENT SERVICES DEPARTMENT - PLANNING | | | DIVISION. |
|
|