| Plan Review Stops For Permit 16100185 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-14 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-14 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-13 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-13 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2016-12-13 09:00:37 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PLAN SHEETS 1, 3 AND 4 DO NOT HAVE THE PROFESSIONAL | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE OR SEAL AS | | | REQUIRED BY FAC 61G15-23.002. | | | | | | 2) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | ASPHALT ROOF SHINGLES (NOA NO. 03-0219.04) EXPIRED IN | | | 2008. SUBMIT TWO SETS OF CURRENT PRODUCT APPROVALS THAT | | | HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. FBC 107.3.4 | | | | | | 3) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | WINDOWS AND DOORS WERE NOT REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD. FBC 107.3.4 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-11-22 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-11-22 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2016-11-22 16:24:34 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE ROOFING MATERIALS, WINDOW/GLASS TYPES AND EXTERIOR | | | DOOR TYPES. ONLY ONE PRODUCT APPROVAL WAS SUBMITTED FOR | | | THE SINGLE HUNG WINDOWS AND NONE WERE SUBMITTED FOR THE | | | DOORS OR ROOFING MATERIAL. | | | | | | 2) THE WALL SECTION AT THE MASTER BATHROOM SPECIFIES | | | ONLY THE ONE LAYER OF FELT ON THE PAPER BACK LATH, | | | WHICH DOES NOT COMPLY WITH R703.6.3 WATER-RESISTIVE | | | BARRIERS. WATER-RESISTIVE BARRIERS SHALL BE INSTALLED | | | AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER | | | WOOD-BASED SHEATHING, SHALL INCLUDE A WATER-RESISTIVE | | | VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST | | | EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE | | | INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH | | | THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE | | | AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION | | | R703.8) INTENDED TO DRAIN TO THE WATER-RESISTIVE | | | BARRIER IS DIRECTED BETWEEN THE LAYERS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-13 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-12-12 |
Time |
15:58 |
Sent To |
B |
|
| Notes |
| 2016-12-12 16:49:23 | 2ND REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | PASSED WITH THE FOLLOWING PROVISO | | | | | | 1] A SWITCHED LIGHTING OUTLET REQUIRED BY MECHANICAL | | | UNIT IN THE ATTIC. NEC 210.70(A)(3) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-10-19 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-10-19 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-10-19 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2016-10-19 11:23:16 | JOB PERMIT NUMBER: 16100185 | | | JOB ADDRESS: 816 41 STREET | | | WEST PALM BEACH FLORIDA | | | DATE: OCTOBER 19, 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA | | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | | AMENDMENTS. BELOW IS A LIST OF ITEMS NOTED. | | | | | | 1] IF THE SERVICE IS OVERHEAD PLEASE REMOVE THE LATERAL | | | UNDERGROUND CONDUIT SHOWN AT THE METER IN THE RISER | | | DIAGRAM. FBC-107 | | | | | | 2] ADD AN INTERSYSTEM BONDING TERMINAL TO THE GROUNDING | | | DETAIL IN THE RISER DIAGRAM. FBC-R SEC E3609.3 | | | | | | 3] PROVIDE THE 200 AMP PANEL LOCATION ON THE FLOOR PLAN | | | TO VERIFY WORK CLEARANCE, SHOW COMPLIANCE. FBC-R SEC | | | E3405 | | | | | | 4] ADD A SMOKE ALARM OUTSIDE OF THE MASTER BED IN THE | | | IMMEDIATE VICINITY OF THE SLEEPING AREA. FBC-R SEC | | | 314.3 | | | | | | 5] ADD A WALL SWITCHED CONTROLLED LIGHTING OUTLET TO | | | PROVIDE OUTDOOR ILLUMINATION FOR THE EXTERIOR DINING | | | ROOM DOOR. FBC-R SEC E3903.3 | | | | | | 6] PROVIDE A GFCI SERVICE RECEPTACLE OUTLET WITHIN 25' | | | OF THE OUTSIDE CONDENSER UNIT. FBC-R SEC E3901.11 | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER | | | RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. CLOUDING THE CHANGES | | | WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER | | | QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME | | | DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-14 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-14 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2016-12-14 11:26:08 | RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-13 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-05 |
Time |
13:05 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-11-22 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-12 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-11-22 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-11-22 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2016-11-22 11:17:50 | IMPACT FEES WERE PAID UNDER PREVIOUS PERMIT #07040598. | | | PR #08-2831 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-14 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-14 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2016-12-14 11:27:41 | MECHANICAL PROVISO | | | | | | M1305.1.3 APPLIANCES IN ATTICS. ATTICS CONTAINING | | | APPLIANCES SHALL BE PROVIDED WITH AN OPENING AND A | | | CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO ALLOW | | | REMOVAL OF THE LARGEST APPLIANCE, BUT NOT LESS THAN 30 | | | INCHES (762 MM) HIGH AND 22 INCHES (559 MM) WIDE AND | | | NOT MORE THAN 20 FEET (6096 MM) LONG MEASURED ALONG THE | | | CENTERLINE OF THE PASSAGEWAY FROM THE OPENING TO THE | | | APPLIANCE. THE PASSAGEWAY SHALL HAVE CONTINUOUS SOLID | | | FLOORING IN ACCORDANCE WITH CHAPTER 5 NOT LESS THAN 24 | | | INCHES (610 MM) WIDE. A LEVEL SERVICE SPACE AT LEAST 30 | | | INCHES (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL | | | BE PRESENT ALONG ALL SIDES OF THE APPLIANCE WHERE | | | ACCESS IS REQUIRED. THE CLEAR ACCESS OPENING DIMENSIONS | | | SHALL BE A MINIMUM OF 20 INCHES BY 30 INCHES (508 MM BY | | | 762 MM), AND LARGE ENOUGH TO ALLOW REMOVAL OF THE | | | LARGEST APPLIANCE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-12-13 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-12-13 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2016-12-13 13:50:04 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ANCHORING DETAIL ON SHEET M-1 SPECIFIES A 2 INCH | | | CONCRETE PAD. M1305.1.4.1 GROUND CLEARANCE. EQUIPMENT | | | AND APPLIANCES SUPPORTED FROM THE GROUND SHALL BE LEVEL | | | AND FIRMLY SUPPORTED ON A CONCRETE SLAB OR OTHER | | | APPROVED MATERIAL EXTENDING NOT LESS THAN 3 INCHES (76 | | | MM) ABOVE THE ADJOINING GROUND. SUCH SUPPORT SHALL BE | | | IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS. APPLIANCES SUSPENDED FROM THE FLOOR SHALL | | | HAVE A CLEARANCE OF NOT LESS THAN 6 INCHES (152 MM) | | | FROM THE GROUND. | | | | | | 2) THE PLANS SHOW THE AIR HANDLER IN THE ATTIC AND IT | | | APPEARS THAT THE DUCTWORK BLOCKS ACCESS FROM THE ACCESS | | | OPENING TO THE APPLIANCE. M1305.1.3 APPLIANCES IN | | | ATTICS. ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED | | | WITH AN OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY | | | LARGE ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, | | | BUT NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | | (559 MM) WIDE AND NOT MORE THAN 20 FEET (6096 MM) LONG | | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | | REMOVAL OF THE LARGEST APPLIANCE. | | | | | | 3) ONLY ONE OF THE ENERGY FORMS WAS SIGNED AND DATED BY | | | THE OWNER. PLEASE HAVE THE OWNER SIGN AND DATE THE | | | OTHER SET. FBC ENERGY R405-2014 | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-11-22 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-11-22 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2016-11-22 14:45:31 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE WALLS OF THE STRUCTURE ARE NOT CLEARLY VISIBLE | | | ON THE HVAC PLAN. FBC 107.2.1 | | | | | | 2) THE EQUIPMENT SCHEDULE ON SHEET M-1 DOES NOT MATCH | | | THE ENERGY FORM OR LOAD CALCULATIONS. THE EER AND SEER | | | ARE DIFFERENT AND THE MODEL NUMBER FOR THE AHU IS | | | DIFFERENT. | | | | | | 3) ONLY ONE COPY OF THE ENERGY AND LOAD CALCULATIONS | | | WERE SUBMITTED. TWO SETS ARE REQUIRED. FBC 107.1 | | | | | | 4) THE OWNER / AGENT IS REQUIRED TO SIGN AND DATE THE | | | ENERGY FORM R405-2014. | | | | | | 5) PROVIDE AN EQUIPMENT ANCHORING DETAIL FOR THE | | | MECHANICAL EQUIPMENT THAT IS LOCATED ON THE EXTERIOR OF | | | THE STRUCTURE.FBC- M301.15 | | | | | | 5) THE AC EQUIPMENT SCHEDULE SPECIFIES THAT THE AIR | | | HANDLER IS LOCATED IN A UTILITY CLOSET AND THE HVAC | | | PLAN SHOWS IT MOUNTED HORIZONTALLY IN THE ATTIC. REVISE | | | AS NECESSARY AND SHOW THE LOCATION OF THE A/H ON THE | | | ARCHITECTURAL PLANS, AS WELL AS, THE HVAC PLANS. FBC | | | 107.2.1 | | | | | | 6) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | THE MECHANICAL PLANS SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-04 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-03 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2016-10-24 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2016-10-21 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|