Plan Review Details - Permit 16100165
Plan Review Stops For Permit 16100165
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-02-13 Cont ID  
Sent By jwitmer Date 2017-02-13 Time 17:14 Rev Time 0.00
Received By jwitmer Date 2017-02-13 Time 16:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-02-03 Cont ID  
Sent By jwitmer Date 2017-02-03 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2017-01-30 Time   Sent To  
Notes
2017-02-03 09:58:222/03/2017 THE DESIGNER OF RECORD JAMES M STERGAS
 E-MAILED THE REQUIRED SOUND INSULATION TEST REPORTS
 ASTM E90 & ASTM E 492 STAMPED FLOORING PRODUCT
 APPROVALS. JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
2017-01-30 14:16:31BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16100165
 ADD: 255 EVERNIA ST. SUITE # 1519
 CONT: ALL FLAGS CONSTRUCTION
 TEL: 561-312-7675
 E-MAIL: STEVE @ ALLFLAGSCONSTRUCTION.COM
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. JAN. 30/2017
 ACTION: DENIED
  
 1)2ND REQUEST. SUBMITTED THIS REVIEW IS A SALES
 BROCHURE HIGHLIGHTED IS THE ACTUAL TEST WE REQUIRE.
 TEST RAL IN98-41 RAFTL98-280 SHOULD SUPPLY THE REQUIRED
 IIC RATING TESTED TO ASTM E492 AND STC RATING TESTED TO
 ASTM E 90. SUBMIT TEST.
  
 SHEET A-1.01 NOTE 11 INDICATES THE REMOVAL OF ALL FLOOR
 TILE AND WOOD FLOORING AND INSULATION, THE PLANS DO NOT
 INDICATE WHAT MATERIAL IS TO BE RE-INSTALLED. THE
 STRAND IS DOCUMENTED AS HAVING 8 INCH CONCRETE FLOOR
 SLABS, EITHER TEST REPORTS FOR 6 INCH AND 8 INCH FLOOR
 SLABS ARE ACCEPTED. SEE SOUND INSULATION REQUIREMENTS
 LISTED BELOW.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-25 Cont ID  
Sent By jwitmer Date 2016-10-25 Time 07:30 Rev Time  
Received By jwitmer Date 2016-10-25 Time   Sent To  
Notes
2016-10-25 07:30:52BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16100165
 ADD: 255 EVERNIA ST. SUITE # 1519
 CONT: ALL FLAGS CONSTRUCTION
 TEL: 561-312-7675
 E-MAIL: STEVE @ ALLFLAGSCONSTRUCTION.COM
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. OCT. 25/2016
 ACTION: DENIED
  
 1) SHEET A-1.01 NOTE 11 INDICATES THE REMOVAL OF ALL
 FLOOR TILE AND WOOD FLOORING AND INSULATION, THE PLANS
 DO NOT INDICATE WHAT MATERIAL IS TO BE RE-INSTALLED.
 THE STRAND IS DOCUMENTED AS HAVING 8 INCH CONCRETE
 FLOOR SLABS, EITHER TEST REPORTS FOR 6 INCH AND 8 INCH
 FLOOR SLABS ARE ACCEPTED. SEE SOUND INSULATION
 REQUIREMENTS LISTED BELOW.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2017-02-22 Cont ID  
Sent By vperez Date 2017-02-22 Time 10:43 Rev Time 0.00
Received By vperez Date 2017-02-22 Time 10:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-01-26 Cont ID  
Sent By vperez Date 2017-01-26 Time 18:27 Rev Time 0.00
Received By vperez Date 2017-01-26 Time 18:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-11-08 Cont ID  
Sent By vperez Date 2016-11-08 Time 14:30 Rev Time 0.00
Received By vperez Date 2016-11-08 Time 14:25 Sent To  
Notes
2016-11-08 14:32:58PLEASE PROVIDE A COMPLETE AND CLEAR SCOPE OF WORK FOR
 AN ACCURATE ELECTRICAL PLAN REVIEW. FBC 107.3.5
  
 FURTHER COMMENTS TO FOLLOW.
  
 QUESTION: VAL PEREZ
 *6717

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2017-02-23 Cont ID  
Sent By pleduc Date 2017-02-23 Time   Rev Time 0.00
Received By pleduc Date 2017-02-22 Time 16:25 Sent To PC
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-01-24 Cont ID  
Sent By pleduc Date 2017-01-24 Time   Rev Time 0.00
Received By pleduc Date 2017-01-24 Time 14:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-10-18 Cont ID  
Sent By pleduc Date 2016-10-18 Time   Rev Time 0.00
Received By pleduc Date 2016-10-18 Time 09:50 Sent To  
Notes
2016-10-18 09:58:15THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THE EXTENT OF THE REMODEL OR REVISION IS UNCLEAR AND
 DOES NOT INDICATE SUFFICIENT DETAIL TO ADDRESS LIFE
 SAFETY CONCERNS OF THE PROPOSED PROJECT.
  
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND
 SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY
 CERTIFIED LIFE SAFETY CONTRACTORS.
  
 2) THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 3) ANY AND ALL WORK ON THE FIRE ALARM AND FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP
 DRAWINGS AND BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 4) ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
 5) PROVIDE MANUFACTURES SPEC'S SMOKE AND FIRE RATINGS
 ON ANY SOUNDPROOF FLOORING PRODUCTS.
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-02-23 Cont ID  
Sent By pleduc Date 2017-02-23 Time   Rev Time 0.00
Received By pleduc Date 2017-02-09 Time 11:28 Sent To  
Notes
2017-02-10 11:31:07B11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-02 Cont ID  
Sent By gjohnson Date 2017-02-02 Time 14:40 Rev Time 0.00
Received By gjohnson Date 2017-01-20 Time 13:02 Sent To  
Notes
2017-01-23 13:03:04B11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-09 Cont ID  
Sent By gjohnson Date 2016-11-09 Time 13:19 Rev Time 0.00
Received By gjohnson Date 2016-10-11 Time 10:33 Sent To  
Notes
2016-10-12 10:33:20B05

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-02-24 Cont ID  
Sent By spalmer Date 2017-02-24 Time 11:33 Rev Time 0.00
Received By spalmer Date 2017-02-24 Time 11:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2017-01-30 Cont ID  
Sent By ccole Date 2017-01-30 Time 17:02 Rev Time 0.00
Received By ccole Date 2017-01-30 Time 17:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-17 Cont ID  
Sent By ccole Date 2016-10-17 Time 07:46 Rev Time 0.00
Received By ccole Date 2016-10-17 Time 07:46 Sent To  
Notes
2016-10-17 07:51:491ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16100165
 10/17/16
  
 1) PROVIDE A SCOPE OF WORK FOR MECHANICAL ALTERATIONS
 WITH DETAILS AND NOTES ON THE PLANS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-02-17 Cont ID  
Sent By gjohnson Date 2017-02-17 Time 11:25 Rev Time 0.00
Received By gjohnson Date 2017-02-16 Time 12:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-02-02 Cont ID  
Sent By gjohnson Date 2017-02-02 Time 14:35 Rev Time 0.00
Received By gjohnson Date 2017-02-02 Time 14:35 Sent To  
Notes
2017-02-02 14:39:152ND REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1.UNDER THE MECHANICAL AND PLUMBING NOTES IT STATES
 THAT THERE IS NO WORK TO ANY EXISTING PLUMBING. UNDER
 THE KEY NOTES #13 SAYS REMOVE EXISTING TUB AND REPLACE
 WITH SHOWER PAN PLEASE CLARIFY/. PER WPB AMEND TO FBC
 107.2.1
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-11-09 Cont ID  
Sent By gjohnson Date 2016-11-09 Time 13:19 Rev Time 0.00
Received By gjohnson Date 2016-11-09 Time 13:19 Sent To  
Notes
***NONE***