Plan Review Details - Permit 16100159
Plan Review Stops For Permit 16100159
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-02-07 Cont ID  
Sent By cthroop Date 2017-01-27 Time 10:55 Rev Time 0.00
Received By cthroop Date 2017-01-27 Time 10:52 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-21 Cont ID  
Sent By cthroop Date 2016-10-21 Time 14:18 Rev Time 0.00
Received By cthroop Date 2016-10-21 Time 13:11 Sent To  
Notes
2016-10-21 14:28:50BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 1. PROVIDE SITE PLAN.
 2. MECHANICAL PERMIT REQUIRED.
 3. ELECTRICAL PERMIT REQUIRED.
 4. PALM BEACH COUNTY IMPACT FEES REQUIRED.
 5. PROVIDE ENERGY SUBMITTAL.
 6. ROOFING PERMIT REQUIRED.
 7. PROVIDE DESIGN WIND LOADS FOR EXT. OPENINGS.
 8. PROVIDE DEMENSIONS FOR EXT. ROUGH OPENINGS.
 9. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM, DOOR
 AND WINDOWS.
  
 FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS,
 FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE
 DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE
 SURVEY.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING,
 WINDOW AND DOOR SUBMITTALS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2017-04-06 Cont ID  
Sent By rlecky Date 2017-04-06 Time 13:32 Rev Time 0.00
Received By rlecky Date 2017-04-06 Time 13:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2017-01-27 Cont ID  
Sent By cthroop Date 2017-01-27 Time 11:04 Rev Time 0.00
Received By cthroop Date 2017-01-27 Time 11:04 Sent To  
Notes
2017-01-27 11:05:27OPENED E STOP BY MISTAKE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-01-05 Cont ID  
Sent By rlecky Date 2017-01-05 Time 13:52 Rev Time 0.00
Received By rlecky Date 2017-01-05 Time 10:42 Sent To  
Notes
2017-01-05 13:55:00PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2014 FBC R314, 315
  
 SMOKE ALARMS ARE REQUIRED TO BE INTERCONNECTED. 2014
 FBC R 314, 315
  
 HIGH HAT CEILING LIGHTING FIXTURES IN INSULATED SPACES
 NEED TO BE RATED FOR INSULATION CONTACT. NEC 410.116;
 FBC R 4004
  
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL BRANCH
 CIRCUITS SUPPLYING OUTLETS. FBC E3902.12, NEC 210.12
  
 VERIFY RECEPTACLES ARE PROPERLY PLACED TO SERVICE ALL
 AREAS INCLUDING WALL SPACES TWO FEET OR MORE IN WIDTH.
 NEC 210.52 (A), FBC R E3901.2
  
 CEILING ELECTRICAL BOXES SUPPORTING PADDLE FANS MUST BE
 LISTED FOR THAT USE. NEC 422.18; FBC R 3905.9
  
 VERIFY ALL NEW RECEPTACLES ARE TAMPER RESISTANT. NEC
 406.2; FBC R E4002.14
  
 VERIFY ALL NEW CIRCUITS ARE AFCI PROTECTED. NEC 210.12;
 FBC R E3902.12
  
 GFCI PROTECTED RECEPTACLES ARE REQUIRED AT FRONT AND
 REAR ELEVATIONS. NEC 210.8
  
 PROVIDE A DETAIL FOR THE TYPE AND SIZE OF CIRCUIT
 PROPOSED TO FEED THE NEW AIR CONDITIONING UNIT(S). FBC
 E3705.5, NEC 240.4
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 561-805-6654(OFFICE)
 561-373-3701(CELL)
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-04-18 Cont ID  
Sent By hmoser Date 2017-04-18 Time 10:12 Rev Time 0.00
Received By hmoser Date 2017-04-14 Time 10:07 Sent To  
Notes
2017-04-17 10:07:37RESUB ROUTED TO HMOSER

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-06 Cont ID  
Sent By rlecky Date 2017-04-06 Time 13:32 Rev Time 0.00
Received By rlecky Date 2017-04-06 Time 13:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-01-31 Cont ID  
Sent By cthroop Date 2017-01-31 Time 07:56 Rev Time 0.00
Received By cthroop Date 2016-12-13 Time 15:43 Sent To  
Notes
2017-01-30 19:03:26ROUTE TO CHRIS THROOP 1/30/2017 - JORGE V.
2016-12-13 15:43:14R02

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-21 Cont ID  
Sent By cthroop Date 2016-10-21 Time 13:11 Rev Time 0.00
Received By cthroop Date 2016-10-11 Time 10:06 Sent To  
Notes
2016-10-12 10:06:18ROUTED TO ZONING

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-05-04 Cont ID  
Sent By cthroop Date 2017-05-04 Time 15:47 Rev Time 0.00
Received By cthroop Date 2017-05-04 Time 15:42 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-01-27 Cont ID  
Sent By cthroop Date 2017-01-27 Time 10:55 Rev Time 0.00
Received By cthroop Date 2017-01-27 Time 10:55 Sent To  
Notes
2017-01-27 10:57:07BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 IMPACT FEES
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2017-04-18 Cont ID  
Sent By hmoser Date 2017-04-18 Time 10:12 Rev Time 0.00
Received By hmoser Date 2017-04-18 Time 09:34 Sent To  
Notes
2017-04-18 10:12:29CALLED CONTRACTOR THE MINNY SPLIT IS NOT GOING TO BE
 INSTALLED
 THEY ARE GOING TO INSTALL A WINDOW UNIT NO MECHANICAL
 PERMIT
 IS REQUIRED
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805 6676
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-01-30 Cont ID  
Sent By cthroop Date 2017-02-07 Time 11:21 Rev Time 0.00
Received By jvalido Date 2017-01-30 Time 17:42 Sent To  
Notes
2017-01-30 17:55:21CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE MECHANICAL PLAN SHOWING LOCATION OF MINI
 SPLIT AHU AND CONDENSER.
 (2) PROVIDE ALL INFORMATION ON WHO DREW PLANS AS PER
 107.2.1.
 (3) PROVIDE EQUIPMENT SCHEDULE ON FLOOR PLAN. ( INCLUDE
 BRAND, MODEL NUMBERS OF ALL EQUIPMENT, SEER, KW HEATER
 OR HP, TOTAL BTU).
  
 FLORIDA ENERGY CODE FBC 2014
  
 (4) FORMS R405-2014 MUST BE SIGNED AT PREPARED BY AND
 AT OWNER/AGENT. (SEE HIGHLIGHTED AREAS ON FORMS).
 (5) HEAT LOAD CALCULATIONS MUST BE FILLED OUT
 COMPLETELY. PROVIDE WHO PREPARED THE CALCULATIONS, DATE
 AND SIGNATURE.(SEE HIGHLIGHTED UPPER RIGHT HAND SIDE OF
 PAPER).
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-05-04 Cont ID  
Sent By cthroop Date 2017-05-04 Time 16:01 Rev Time 0.00
Received By cthroop Date 2017-05-04 Time 16:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-12-15 Cont ID  
Sent By njwira Date 2016-12-15 Time 10:56 Rev Time 0.00
Received By njwira Date 2016-12-14 Time 17:08 Sent To  
Notes
2016-12-15 10:58:2412/15/16- PASSED
  
 HARD ROOF CONSIDERED PART OF THE HOUSE
 NO LANDSCAPE PERMIT REQUIRED
 NO TREE ALTERATION PERMIT REQUIRED
 ZONE: SF-7 SINGLE FAMILY LOW DENSITY RESIDENTIAL
 REAR SETBACK IS 20.48FT. MEETING 15FT. REQUIREMENT
 SIDE SETBACK MET
 ONE(1) STORY MEETS 30FT. LIMIT
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-10-14 Cont ID  
Sent By njwira Date 2016-10-14 Time 13:46 Rev Time 0.00
Received By njwira Date 2016-10-12 Time 14:50 Sent To B
Notes
2016-10-14 13:47:0210/14/16- FAILED
  
 MUST PROVIDE A SURVEY SHOWING WHERE THE ENCLOSURE IS
 GOING.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  