Plan Review Details - Permit 16100126
Plan Review Stops For Permit 16100126
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-12-06 Cont ID  
Sent By jwitmer Date 2016-12-06 Time 06:23 Rev Time 0.00
Received By jwitmer Date 2016-12-06 Time 06:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-10-26 Cont ID  
Sent By jwitmer Date 2016-10-26 Time 14:48 Rev Time  
Received By jwitmer Date 2016-10-26 Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-10-24 Cont ID  
Sent By vperez Date 2016-10-24 Time 09:52 Rev Time 0.00
Received By vperez Date 2016-10-24 Time 09:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-10-27 Cont ID  
Sent By scaldero Date 2016-10-27 Time 16:01 Rev Time 0.00
Received By scaldero Date 2016-10-17 Time 11:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-06 Cont ID  
Sent By jwitmer Date 2016-12-06 Time 06:24 Rev Time 0.00
Received By jwitmer Date 2016-11-10 Time 12:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-11-08 Cont ID  
Sent By lmarchan Date 2016-11-08 Time 12:52 Rev Time 0.00
Received By lmarchan Date 2016-10-12 Time 09:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-10-26 Cont ID  
Sent By ccole Date 2016-10-26 Time 09:58 Rev Time 0.00
Received By ccole Date 2016-10-26 Time 09:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-11-30 Cont ID  
Sent By tklarge Date 2016-11-30 Time 14:40 Rev Time 0.00
Received By tklarge Date 2016-11-15 Time 05:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-11-08 Cont ID  
Sent By tklarge Date 2016-11-08 Time 11:23 Rev Time 0.00
Received By tklarge Date 2016-11-08 Time 11:09 Sent To  
Notes
2016-11-08 11:09:361) SHT. A2.02 - THE ROOF PLAN IS ALMOST IMPOSSIBLE TO
 READ DUE TO THE BACKGROUND DOTS. SUBMIT A CLEAN ROOF
 PLAN FOR REVIEW. WPB AMEND. TO FBC SEC. 107.2.1.
 2) SHT. A8.04 - DETAIL # 10 - THE LOCATION OF OVERFLOW
 SCUPPERS IN THE PARAPET WALL SHALL COMPLY WITH 2014 FBC
 SEC. 1503.4.2.1.
 3) SHT. A8.03 - VANITY TOP PLAN- THERE IS A NOTE THAT
 READS "FIRST FLOOR ONLY." CLARIFY.
 4) SHT. A0.02 - THERE IS A CLOUDED NOTE AT THE TOP OF
 THE PAGE THAT READS " PROVIDE WOOD BLOCKING IN ALL
 FIRST FLOOR UNITS FOR FUTURE HANDICAP GRAB BARS". WOOD
 BLOCKING SHALL BE PROVIDED IN SLL UNITS PER THE FHA.
 5) SHTA2.01 - REMOVE THE BACKGROUND DOTS FROM THE FLOOR
 PLAN.IT IS EXTREMELY DIFFICULT TO SEE THE CLEAR FLOOR
 SPACE FOR THE FIXTURES AND COMPLIANCE WITH THE FHA.
 6) SHT. P2.01 - THE HUB DRAIN IN THE TRASH ROOM THAT
 RECEIVES THE DISCHARGE FROM THE ELEVATOR SUMP SHALL BE
 EQUIPPED WITH A TRAP PRIMER PER THE 2014 FBC-PLUMBING
 SEC.1002.4.
 7) SHT. P5.01 - RISER W/JS SHOWS THE WATER SUPPLY FOR
 MOP SINKS ON FLOORS 2 & 3 DELETED BUT THE MOP SINKS ARE
 STILL SHOWN ON RISER S/JS.CLARIFY.
 8) SUBMIT A NARRATIVE THAT CLEARLY DESCRIBES WHAT
 CHANGES HAVE BEEN MADE TO THE PLUMBING SYSTEMS AND
 WHERE THE CHANGES OCCUR.WPB AMEND. TO FBC SEC. 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2016-12-06 Cont ID  
Sent By jwitmer Date 2016-12-06 Time 06:23 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2016-10-26 14:50:10ARCHITECTURAL AND STRUCTURAL SHEETS REVIEWED FOR
 SIGNATURES, APPROVED. JW
2016-10-26 09:59:16MECHANICAL SIGNATURES VERIFIED/CC
 10/25/16

Review Stop Z ZONING
Rev No 1 Status P Date 2016-11-01 Cont ID  
Sent By ajones Date 2016-11-01 Time 16:38 Rev Time 0.00
Received By ajones Date 2016-11-01 Time 16:38 Sent To  
Notes
***NONE***