| 2016-10-11 09:29:55 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER ? PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | THRESHOLD BUILDING |
| | |
| | 1. SPECIAL INSPECTOR AGREEMENT INCOMPLETE. |
| | 1A. PER FS 553.79 THE SPECIAL INSPECTOR MUST BE AN |
| | ENGINEER LICENSED UNDER CHAPTER 471, AN ARCHITECT |
| | LICENSED UNDER CHAPTER 481 OR A STANDARD INSPCTOR |
| | LICENSED UNDER CHAPTER 468. PLEAS REMOVE THE EIT, MR |
| | ADAM COON FROM THE AGREEMENT. |
| | NOTE. MR COON MAY BE USED TO OBSERVE THE APPLICATION OF |
| | WATERPROOFING ON THE BUILDING. |
| | 1B. OWNER MUST SIGN AND DATE AGREEMENT (SEE PAGE 4 OF |
| | 6). |
| | 1C. CONTRACTOR MUST SIGN AND DATE AGREEMENT (SEE PAGE 5 |
| | OF 6). |
| | |
| | 2. SPECIAL INSPECTOR AGREEMENT MUST BE SUBMITTED IN |
| | TRIPLICATE. |
| | |
| | 3. THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY |
| | FOR THIS TYPE OF CONSTRUCTION. |
| | |
| | 4. THE RESIDENT INSPECTOR AGREEMENT SUBMITTED AS PART |
| | OF THIS APPLICATION IS NOT REQUIRED. |
| | |
| | 5. THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. |
| | CONSTRUCTION SERVICES DEPARTMENT REQUESTS FOR THRESHOLD |
| | BUILDINGS, A SPECIAL INSPECTOR IS REQUIRED BY F.S. |
| | 553.79 (5) TO THE MINIMUM INSPECTIONS REQUIRED BY THIS |
| | CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED TO BE |
| | FILLED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED AND |
| | RETURNED TO THIS OFFICE AND REVIEWED AND APPROVED |
| | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. CONTACT KEN |
| | CONRAD, MANAGER OF SPECIAL INSPECTOR PROGRAM AT (561) |
| | 805-6666 FOR FURTHER INFORMATION BEFORE THE PERMIT MAY |
| | BE ISSUED. |
| | |
| | 6. JOB INSPECTOR ? FBC 110.3.7.6 THE BUILDING |
| | DEPARTMENT MAY ALLOW A SPECIAL INSPECTOR TO CONDUCT THE |
| | MINIMUM STRUCTURAL INSPECTION OF THRESHOLD BUILDINGS |
| | REQUIRED BY THIS CODE, SECTION 553.73,FLORIDA STATUTES, |
| | WITHOUT DUPLICATIVE INSPECTION BY THE BUILDING |
| | DEPARTMENT. THE BUILDING OFFICIAL IS RESPONSIBLE FOR |
| | ENSURING THAT ANY PERSON CONDUCTING INSPECTIONS IS |
| | QUALIFIED AS A BUILDING INSPECTOR UNDER PART XII OF |
| | CHAPTER 468, FLORIDA STATUTES, OR CERTIFIED AS A |
| | SPECIAL INSPECTOR UNDER CHAPTER 471 OR 481, FLORIDA |
| | STATUTES. INSPECTIONS OF THRESHOLD BUILDINGS REQUIRED |
| | BY SECTION 553.79(5), FLORIDA STATUTES, ARE IN ADDITION |
| | TO THE MINIMUM INSPECTIONS REQUIRED BY THIS CODE. |
| | FBC 110.3.7.4.1 THE SPECIAL INSPECTOR, UPON COMPLETION |
| | OF THE BUILDING AND PRIOR TO THE ISSUANCE OF A |
| | CERTIFICATE OF OCCUPANCY OR COMPLETION, FILE A SIGNED |
| | AND SEALED STATEMENT WITH THE ENFORCEMENT AGENCY IN |
| | SUBSTANTIALLY THE FOLLOWING FORM: ?TO THE BEST OF MY |
| | KNOWLEDGE AND BELIEF, THE CONSTRUCTION OF ALL |
| | STRUCTURAL LOAD-BEARING COMPONENTS DESCRIBED IN THE |
| | THRESHOLD INSPECTION PLAN COMPLIES WITH THE PERMITTED |
| | DOCUMENTS AND THE SPECIALTY SHORING DESIGN PROFESSIONAL |
| | ENGINEER HAS ASCERTAINED THAT THE SHORING AND RESHORING |
| | CONFORMS WITH THE SHORING AND RESHORING PLANS SUBMITTED |
| | TO THE ENFORCEMENT AGENCY?. |
| | |
| | 7. NOTICE ONLY. PLEASE CALL THE CITY OF WEST PALM |
| | BEACH?S AUTOMATED TELEPHONE INSPECTION LINE @ (561) |
| | 805-6700 FOR ALL BUILDING INSPECTIONS FOR AUDITING OF |
| | JOBSITE INSPECTIONS. WITHOUT THIS, THE PERMIT EXPIRES |
| | IN 6 MONTHS WHICH WILL RESULT IN ?ABANDONMENT OF JOB, |
| | NO INSPECTION ACTIVITY?. THE PERMIT WILL BECOME |
| | EXPIRED. |
| | |
| | 8. PLEASE PROVIDE A SITE PLAN SHOWING THE PROPERTY |
| | LINES, CONSTRUCTION AREAS, STAGING AREAS, HOW THE |
| | OCCUPANTS OF THE BUILDING WILL BE SAFE GUARDED DURING |
| | THEIR ENTRY AND EXIT OF THE BUILDING. SHOW COMPLIANCE |
| | WITH 2014 FBC 3306.7 ? COVERED WALKWAYS, INCLUDING |
| | LIGHTING FOR THE EXIT DISCHARGE. 2014 FBC 3310.2 ? |
| | MAINTENANCE OF MEANS OF EGRESS. REQUIRED MEANS OF |
| | EGRESS SHALL BE MAINTAINED AT ALL TIMES DURING |
| | CONSTRUCTION, DEMOLITION, REMODELING OR ALTERATIONS AND |
| | ADDITIONS TO ANY BUILDING. |
| | |
| | 9. IF SCAFFOLDING EXTENDS BEYOND THE PRIVATE PROPERTY |
| | AND ONTO CITY RIGHT OF WAY, ENGINEERING WILL REQUIRE |
| | RIGHT OF WAY PERMITS. PLEASE CONTACT MANNY GONZALEZ AT |
| | THE ENGINEERING DEPARTMENT ? (561) 494-1085. |
| | 9A. IF SCAFFOLDING IS TO BE USED FOR THE HEIGHT OF THE |
| | BUILDING, PLEASE PROVIDE HOW THE SCAFFOLDING WILL BE |
| | BUILT AS WELL AS HOW THE SCAFFOLDING WILL BE ANCHORED |
| | TO RESIST LATERAL WIND LOADING. THERE APPEARS SAND |
| | BLASTING WILL ALSO BE AN ELEMENT OF THE OPERATION, HOW |
| | WILL THE SANDBLASTING BE CONTAINED, WILL THERE BE WIND |
| | SCREENS, IF SO PLEASE PROVIDE WHAT ELEMENTS WILL BE |
| | INTRODUCED TO KEEP THE SCAFFOLDING FROM MOVING WITH THE |
| | LATERAL EFFECT OF WIND ON THE WIND SCREENS. AT WHAT |
| | SAFETY FACTOR ARE THESE ELEMENTS FACTORED? 107.2.1.3 |
| | ADDITIONAL INFORMATION. 2014 FBC 3302.1 & 3306.1. |
| | |
| | 10. PROVIDE COMPLIANCE WITH FBC 3309.1 WHERE REQUIRED. |
| | ALL STRUCTURES UNDER CONSTRUCTION, ALTERATION OR |
| | DEMOLITION SHALL BE PROVIDED WITH NO FEWER THAN ONE |
| | APPROVED PORTABLE FIRE EXTINGUISHER IN ACCORDANCE WITH |
| | SECTION 906 AND SIZED FOR NOT LESS THAN ORDINARY HAZARD |
| | AS FOLLOWS: |
| | 10A. AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE |
| | COMBUSTIBLE MATERIALS HAVE ACCUMULATED. |
| | 10B. IN EVERY STORAGE AND CONSTRUCTION SHED. |
| | 10C. ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE |
| | PROVIDED WHERE SPECIAL HAZARDS EXIST, SUCH AS THE |
| | STORAGE AND USE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS. |
| | |
| | 11. DURING RESTORATION WORK ON BALCONIES, DEMONSTRATE |
| | HOW THE TENANTS WILL BE SAFE GUARDED FROM THE WORK AREA |
| | AND EGRESS ONTO THE BALCONIES. FBC 3306.1 PROTECTION |
| | REQUIRED. |
| | |
| 2016-10-04 11:07:10 | ASSURE NO RIGHT-OF-WAY PERMIT REQUIRED AND PROTECTION |
| | OF THE PUBLIC IS PROVIDED. SEE ALSO THE RE-ROOF PERMIT |
| | AS THESE ISSUES WERE DEALT WITH THERE AND MAY ALREADY |
| | BE RESOLVED. REMOVED ZONING STOP & ROUTED TO CTHROOP. |