Plan Review Details - Permit 16091070
Plan Review Stops For Permit 16091070
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-01-26 Cont ID  
Sent By cthroop Date 2017-01-26 Time 14:30 Rev Time 0.00
Received By cthroop Date 2017-01-26 Time 14:30 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-17 Cont ID  
Sent By cthroop Date 2016-10-17 Time 10:25 Rev Time 0.00
Received By cthroop Date 2016-10-17 Time 10:03 Sent To P
Notes
2016-10-17 10:29:01BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 1. SPECIFY NEW DECKING MATERIAQL.
 2. PROVIDE DETAIL FOR RE-INFORCING FOR ALL NEW
 STRUCTURAL CONCRETE.
 3. PROVIDE SITE PLAN, IDENTIFY POOL BARRIER PER FBC
 454.1.3.1.9.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 SECTION 454 SWIMMING POOLS AND BATHING PLACES (PUBLIC)
 454.1.3.1.9
  
 ALL PUBLIC POOLS SHALL BE SURROUNDED BY A MINIMUM 48
 INCH (1219 MM) HIGH FENCE OR OTHER APPROVED SUBSTANTIAL
 BARRIER. THE FENCE SHALL BE CONTINUOUS AROUND THE
 PERIMETER OF THE POOL AREA THAT IS NOT OTHERWISE
 BLOCKED OR OBSTRUCTED BY ADJACENT BUILDINGS OR
 STRUCTURES AND SHALL ADJOIN WITH ITSELF OR ABUT TO THE
 ADJACENT MEMBERS. ACCESS THROUGH THE BARRIER OR FENCE
 FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS, MOTEL
 ROOMS AND HOTEL ROOMS, SHALL BE THROUGH SELF-CLOSING,
 SELF-LATCHING LOCKABLE GATES OF 48 INCH (1219 MM)
 MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH THE LATCH
 LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM THE
 BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) BELOW
 THE TOP OF THE GATE ON THE POOL SIDE. IF THE
 SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING
 AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR
 INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF
 SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864
 MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED
 FLOOR OR GROUND. DOORED ACCESS POINTS FROM PUBLIC ROOMS
 SUCH AS LOBBIES OR CLUB HOUSES NEED NOT BE THROUGH
 GATES IF THE DOOR(S) MEET THE SAME SELF-CLOSING,
 SELF-LATCHING REQUIREMENTS AS A GATE. GATES SHALL OPEN
 OUTWARD AWAY FROM THE POOL AREA. A LATCHED, LOCKABLE
 GATE SHALL BE PLACED IN THE FENCE WITHIN TEN FEET (3048
 MM) OF THE CLOSEST POINT BETWEEN THE POOL AND THE
 EQUIPMENT AREA FOR SERVICE ACCESS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-01-26 Cont ID  
Sent By mvaldes Date 2017-01-26 Time 09:40 Rev Time 0.00
Received By mvaldes Date 2017-01-26 Time 09:30 Sent To B
Notes
2017-01-26 09:41:40COMPLY WITH NEC 680.26 EQUALPOTENTIAL BONDING.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-10-13 Cont ID  
Sent By mvaldes Date 2016-10-13 Time 17:20 Rev Time 0.00
Received By mvaldes Date 2016-10-13 Time 16:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-01-30 Cont ID  
Sent By gjohnson Date 2017-01-30 Time 09:57 Rev Time 0.00
Received By gjohnson Date 2017-01-13 Time 14:08 Sent To  
Notes
2017-01-17 14:08:46RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-20 Cont ID  
Sent By gjohnson Date 2016-10-20 Time 10:06 Rev Time 0.00
Received By gjohnson Date 2016-09-29 Time 11:17 Sent To  
Notes
2016-09-30 11:17:25ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-01-30 Cont ID  
Sent By gjohnson Date 2017-01-30 Time 09:57 Rev Time 0.00
Received By gjohnson Date 2017-01-30 Time 09:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-10-20 Cont ID  
Sent By gjohnson Date 2016-10-20 Time 10:05 Rev Time 0.00
Received By gjohnson Date 2016-10-20 Time 10:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-01-18 Cont ID  
Sent By njwira Date 2017-01-18 Time 14:00 Rev Time 0.00
Received By njwira Date 2017-01-17 Time 15:08 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-10-11 Cont ID  
Sent By njwira Date 2016-10-11 Time 16:56 Rev Time 0.00
Received By njwira Date 2016-09-30 Time 14:52 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved