| Plan Review Stops For Permit 16091004 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-12-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-01 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-01 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-26 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-26 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-12-05 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-12-05 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-12-05 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-10-24 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-24 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-10-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-10-17 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-10-17 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-12-15 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-11-16 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-11-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-11-15 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-10-12 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-15 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-11-29 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-17 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-17 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-15 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-15 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-11-08 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-11-08 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-11-08 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2016-11-08 10:26:12 | 1) SHT. A2.02 - THE ROOF PLAN IS ALMOST IMPOSSIBLE TO | | | READ DUE TO THE BACKGROUND DOTS. SUBMIT A CLEAN ROOF | | | PLAN FOR REVIEW. WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) SHT. A8.04 - DETAIL # 10 - THE LOCATION OF OVERFLOW | | | SCUPPERS IN THE PARAPET WALL SHALL COMPLY WITH 2014 FBC | | | SEC. 1503.4.2.1. | | | 3) SHT. A8.03 - VANITY TOP PLAN- THERE IS A NOTE THAT | | | READS "FIRST FLOOR ONLY." CLARIFY. | | | 4) SHT. A0.02 - THERE IS A CLOUDED NOTE AT THE TOP OF | | | THE PAGE THAT READS " PROVIDE WOOD BLOCKING IN ALL | | | FIRST FLOOR FOR FUTURE HANDICAP GRAB BARS". WOOD | | | BLOCKING SHALL BE PROVIDED IN SLL UNITS PER THE FHA. | | | 5) SHT. P5.01 - RISER S/JS - THE RISER STILL SHOWS THE | | | MOP SINKS ON LEVELS #2 & #3 BUT THE NARRATIVE STATES | | | THESE MOP SINKS ARE TO BE DELETED. CLARIFY. | | | 6) SHT. P1.01 - THE HUB DRAIN RECEIVING THE DISCHARGE | | | FROM THE ELEVATOR SUMP SHALL BE EQUIPPED WITH A TRAP | | | PRIMER PER 2014 FPC SEC.1002.4. | | | 7) A2.01 - REMOVE THE BACKGROUND DOTS FROM THE FLOOR | | | PLAN. IT IS VERY DIFFICULT TO SE THE CLEAR FLOOR SPACE | | | FOR THE FIXTURES AND COMPLIANCE WITH THE FHA. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-12-15 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-12-15 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2016-12-15 13:32:12 | PLUM SHEETS OK PER GJOHNSON (SEE ATT EMAIL) | | 2016-10-26 15:51:16 | ARCHITECTURAL & STRUCTURAL PLANS CHECKED FOR SIGNATURE. | | | JW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-11-17 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2016-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2016-11-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-11-17 16:45:35 | NO CHANGES TO THE APPROVED SITE PLAN OR BUILDING | | | FOOTPRINT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-11-14 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-11-14 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2016-11-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-11-14 12:40:09 | ** NO CHANGES TO APPROVED SITE PLAN OR BUILDING | | | FOOTPRINT. ** | | | | | | ZONING PROVISIO: | | | | | | THE APPLICANT SHALL OBTAIN A ROW PERMIT FROM THE PALM | | | BEACH COUNTY DEPARTMENT OF ENGINEERING AND PUBLIC WORKS | | | FOR THE ACCESS POINT ON SKEES ROAD PRIOR TO FIRST | | | INSPECTION. A COPY OF THE ROW PERMIT SHALL BE SUBMITTED | | | TO THE DEVELOPMENT SERVICES DEPARTMENT - PLANNING | | | DIVISION. |
|
|