| Plan Review Stops For Permit 16090886 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-18 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-18 |
Time |
06:40 |
Sent To |
|
|
| Notes |
| 2016-10-18 07:01:37 | BUILDING PROVISO: | | | SHEET A1.00 | | | 2014 FBC-ACCESSIBILITY CODE 703.4. | | | 703.4 INSTALLATION HEIGHT AND LOCATION. | | | SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH 703.4. | | | | | | 703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND. | | | TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES | | | MINIMUM | | | ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM | | | THE BASELINE | | | OF THE LOWEST TACTILE CHARACTER AND 60 INCHES MAXIMUM | | | ABOVE THE | | | FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE | | | BASELINE OF THE | | | HIGHEST TACTILE CHARACTER. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-31 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-31 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-10-26 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-26 |
Time |
10:21 |
Sent To |
M |
|
| Notes |
| 2016-10-26 10:19:54 | 2ND ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | PREVIOUS COMMENTS NOT ADDRESSED AND NEW DUE TO NEW | | | SERVICES: | | | | | | 1. NEW RISER SHEET SUBMITTED IS COMPLETELY NEW AND | | | REQUIRES ADDITIONAL COMPLIANCE. PLEASE LABEL PER NEC | | | 230.2E THE TWO NEW SERVICES NOW SHOWN TO BUILDING WITH | | | PERMANENT PLAQUE INDICATING PER VERBIAGE IN THE CODE. A | | | NOTE WILL SUFFICE. | | | 2. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO | | | INDICATE NEC 110.16. ARC FLASH WARNING SIGNS AND NEC | | | 110.24- AVAILABLE FAULT CURRENT- FIELD MARKINGS; SEE | | | VERBIAGE IN CODE. | | | 3. PER NEC 702.4B1- MANUAL TRANSFER SWITCH AND NEC | | | 702.7 SIGNS-SIGNAGE REQUIREMENTS TO BE MET. SEE CODE; | | | ADD NOTE TO RISER. | | | 1. PLEASE ADD A GENERAL NOTE TO INDICATED REQUIRED | | | SEPARATE PERMITS FOR LOW VOLTAGE SYSTEMS AND SITE | | | LIGHTING. FBC 107.3.5 | | | 2. PER FBC EC 405.7- A MINIMUM OF 50% OF ALL 125V, 15 | | | AND 20AMP RECEPTACLES SHALL BE AUTOMATICALLY CONTROLLED | | | WHERE INSTALLED IN PRIVATE OR OPEN OFFICES AND COMPUTER | | | CLASSROOMS. THIS INCLUDES MODULAR PARTITIONS TOO. SHOW | | | COMPLIANCE ACCORDINGLY. | | | 3. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | | THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-09-27 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-09-27 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-09-27 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2016-09-27 11:12:06 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA RES BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | | | | 1. PLEASE ADD A GENERAL NOTE TO INDICATED REQUIRED | | | SEPARATE PERMITS FOR LOW VOLTAGE SYSTEMS. FBC 107.3.5 | | | 2. PER FBC EC 405.7- A MINIMUM OF 50% OF ALL 125V, 15 | | | AND 20AMP RECEPTACLES SHALL BE AUTOMATICALLY CONTROLLED | | | WHERE INSTALLED IN PRIVATE OR OPEN OFFICES AND COMPUTER | | | CLASSROOMS. THIS INCLUDES MODULAR PARTITIONS TOO. SHOW | | | COMPLIANCE ACCORDINGLY. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-10-03 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-10-03 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-10-03 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-31 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-27 |
Time |
14:48 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-26 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-25 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2016-10-25 16:14:42 | VPEREZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-10-21 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-09-23 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-10-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-18 |
Time |
06:46 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-18 |
Time |
06:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-31 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-31 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-10-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-26 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-26 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2016-10-26 15:34:45 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16090886 | | | 10/3/2016 | | | | | | 1) PROVIDE A CHILLED WATER PIPING PLAN SHOWING ALL NEW | | | PIPING RUNS AND POINTS OF CONNECTIONS TO EXISTING | | | PIPING. PLEASE INCLUDE DETAILS- TYPE AND SIZE OF PIPES, | | | AND PIPE INSULATION. | | | | | | 2) ENERGY FORM C402-2014: A) THE FORM MUST BE SIGNED BY | | | THE PERSON WHO PREPARED IT, AND BY THE OWNER/AGENT. B) | | | SHOW COMPLIANCE DATA FOR THE CHILLED WATER PIPING, FAN | | | COIL UNITS, AND THE NEW REPLACEMENT WINDOWS- SECTION | | | C101.4.3 FBC-14 ENERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-03 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-03 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2016-10-03 09:43:15 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16090886 | | | 10/3/2016 | | | | | | 1) PROVIDE A CHILLED WATER PIPING PLAN SHOWING ALL NEW | | | PIPING RUNS AND POINTS OF CONNECTIONS TO EXISTING | | | PIPING. PLEASE INCLUDE DETAILS- TYPE AND SIZE OF PIPES, | | | AND PIPE INSULATION. | | | | | | 2) ENERGY FORM C402-2014: A) THE FORM MUST BE SIGNED BY | | | THE PERSON WHO PREPARED IT, AND BY THE OWNER/AGENT. B) | | | SHOW COMPLIANCE DATA FOR THE CHILLED WATER PIPING, FAN | | | COIL UNITS, AND THE NEW REPLACEMENT WINDOWS- SECTION | | | C101.4.3 FBC-14 ENERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-10-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-10-21 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-10-21 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|