Plan Review Details - Permit 16090809
| Plan Review Stops For Permit 16090809 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-06 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-06 |
Time |
06:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-03-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-22 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-22 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2017-03-22 09:32:03 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16090809 | | | ADD: 2201 45TH ST. | | | CONT: KNIGHT ELECTRIC CO. | | | TEL: 561-689-3500 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. MARCH 22/ 2017 | | | ACTION: DENIED | | | | | | 1) COMPLIED. SHEET D304 NOTE # 3 MIAMI-DADE NOA | | | 16-0330.11. | | | | | | 2) SEMI- COMPLIED. PLEASE NOTE IT IS ASSUMED THERE WERE | | | 2 BINDERS SUBMITTED FOR REVIEW WITH WRITTEN RESPONSE | | | COMMENT, PRODUCT APPROVALS, GENERATOR SPECS AND | | | ADDITIONAL INFORMATION. TO DATE ONLY 1 BINDER HAS BEEN | | | LOCATED. FOR THE NEXT REVIEW (2) BINDERS WILL BE | | | REQUIRED FOR REVIEW. 2014 FLORIDA BUILDING CODE W 2014 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION 107.1 SUBMITTAL | | | DOCUMENTS CONSISTING OF CONSTRUCTION DOCUMENTS, | | | STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH | | | PERMIT APPLICATION. | | | | | | 1ST REVIEW COMMENTS. PLEASE PROVIDE COMPLIANCE WITH | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION / 2014 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. HIGHLIGHT PRESSURES FOR USE | | | WITH PANIC HARDWARE!!!!! | | | (C) PANEL WALLS: WALL LOUVERS (NEW COMMENT) | | | | | | LOUVERS: NOA 16-0209.03 & NOA 16-0519.10 NO TECHNICAL | | | SHEETS WERE SUBMITTED IN THIS REVIEW. | | | | | | 3) SEMI-COMPLIED. FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 4) COMPLIED. (NEED 2ND COPY OF BINDERS). WIND DESIGN | | | CRITERIA. | | | | | | 5) SEMI- COMPLIED NEED THE 2ND BINDER. SHEET D304 NOTE | | | # 2 INDICATES THIS DOOR IS A NEW OUT SWING DOOR AND | | | FRAME, IT APPEARS TO BE AN EXTERIOR DOOR. PLEASE | | | PROVIDE COMPLIANCE WITH 2014 FLORIDA BUILDING CODE W | | | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION / 2014 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE | | | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: (31)(A) EXTERIOR DOORS. HIGHLIGHT PRESSURES | | | FOR USE WITH PANIC HARDWARE!!!!! | | | | | | 6) 2ND REQUEST, NO RESPONSE COMMENTS. NOTICE ONLY, | | | SHEET D321 SHOWS THE REPLACEMENT OF AN EXISTING | | | GENERATOR, THIS BUILDING IS LOCATED IN AN A8 FLOOD ZONE | | | WITH REQUIRED BFE OF 14.0 FT. NGVD. SEPT. 12/2016 THE | | | CITY?S FREEBOARD WAS CHANGED TO AN ADDITIONAL 1-0 FOOT. | | | THIS BUILDING WAS BUILT IN 1975 PRE-FIRM AND IS NOT | | | SUBSTANTIAL IMPROVEMENT. CURRENTLY NO ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-24 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-24 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2016-10-24 11:16:20 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16090809 | | | ADD: 2201 45TH ST. | | | CONT: KNIGHT ELECTRIC CO. | | | TEL: 561-689-3500 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. OCT. 24/ 2016 | | | ACTION: DENIED | | | | | | 1) SHEET D304 NOTE # 3 INDICATES THE REPLACEMENT OF | | | DOOR & FRAME WITH A MIAMI-DADE NOA 16-0330.11 OR EQUAL. | | | CANNOT SAY EQUAL. 2014 FLORIDA BUILDING CODE W 2014 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. | | | | | | 2) PLEASE PROVIDE COMPLIANCE WITH 2014 FLORIDA BUILDING | | | CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION / 2014 FBC-B | | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. HIGHLIGHT PRESSURES FOR USE | | | WITH PANIC HARDWARE!!!!! | | | | | | 3) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 4) PLEASE PROVIDE COMPLIANCE WITH WIND DESIGN, NOTE | | | HOSPITALS HAVE A RISK CATEGORY IV OR A 180 VULT WIND | | | DESIGN SEE TABLE 1604.5 & FIGURE 1609B. 2014 FBC-B | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 4.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 4.2. RISK CATEGORY. | | | | | | 4.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. | | | | | | 4.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 4.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 5) SHEET D304 NOTE # 2 INDICATES THIS DOOR IS A NEW OUT | | | SWING DOOR AND FRAME, IT APPEARS TO BE AN EXTERIOR | | | DOOR. PLEASE PROVIDE COMPLIANCE WITH 2014 FLORIDA | | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION / 2014 | | | FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: (31)(A) EXTERIOR DOORS. HIGHLIGHT | | | PRESSURES FOR USE WITH PANIC HARDWARE!!!!! | | | | | | 6) NOTICE ONLY, SHEET D321 SHOWS THE REPLACEMENT OF AN | | | EXISTING GENERATOR, THIS BUILDING IS LOCATED IN AN A8 | | | FLOOD ZONE WITH REQUIRED BFE OF 14.0 FT. NGVD. SEPT. | | | 12/2016 THE CITY?S FREEBOARD WAS CHANGED TO AND | | | ADDITIONAL 1-0 FOOT. THIS BUILDING WAS BUILT IN 1975 | | | PRE-FIRM AND IS NOT SUBSTANTIAL IMPROVEMENT. CURRENTLY | | | NO ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-07-17 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-07-13 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2017-07-17 14:34:21 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED SIGNED SEALED PLANS PRIOR TO FIRST ELECTRICAL | | | INSPECTION 7/17/17 | | | PAGES D330, 331, 340, 341 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-06-20 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-06-08 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2017-06-20 14:53:46 | 16090809 | | | 2201 45TH STREET | | | HOSPITAL ELECTRIC UPGRADE | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | TEMPORARY FEEDERS ARE UNDERSIZED BASED ON THE PROPOSED | | | SIZE OF CONDUCTORS WITH OVERCURRENT PROTECTION. | | | ADDITIONAL INFORMATION IS NEEDED REGARDING CONDUCTOR | | | PROPERTIES, PHYSICAL PROTECTION, BUNDLING, ETC. NEC | | | 310.10 | | | | | | VERIFY THAT ALL REQUIRED EGRESS DOORS FROM THE | | | ELECTRICAL EQUIPMENT ROOMS SWING IN THE APPROPRIATE | | | DIRECTION AND ARE THE PROPER HEIGHT AND WIDTH. NEC | | | 110.26 | | | | | | THE FOLLOWING ITEMS REQUIRE SOME CLARIFICATION: | | | | | | HAVE THEN NOTED EXISTING PANELS BEEN INCLUDED OR | | | ABANDONED WITH THE NEW PLANS? PANELS ECB, ELS, PNA, | | | PNB, RMI, H1ECRDP, H1ELSA, CHLRRAD. | | | | | | VERIFY OR INDICATE THE CORRECT VOLTAGE FOR PANEL NPB | | | AND TRANSFORMER T-PB WHICH IS FED FROM SECTION 3 OF THE | | | NEW MSB. | | | | | | PANEL RZA1 IS LISTED TWICE AND SHOWN AT 80 AND AT | | | 90AMPS. IT IS SHOWN AS FED FROM BOTH CRPD2 AND LSDP2. | | | | | | HAS THE EXISTING ATS 4 BEEN INCLUDED OR ABANDONDED? | | | | | | | | | ROBERT LECKY | | | PLANS EXAMINER | | | 561-805-6654 | | | 561-373-3701 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-03-06 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-06 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-06 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2017-03-06 13:49:37 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. HAVE CONTACTED DESIGNER OF RECORD DUE TO ELECTRICAL | | | DESIGN AS SHOWN ON PLANS. THEY WILL CONTACT US BACK TO | | | MEET AND CLARIFY. | | | 2. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | | THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-10-13 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-10-12 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2016-10-13 11:37:27 | JOB PERMIT NUMBER: 16090809 | | | JOB ADDRESS: 2201 45TH ST | | | WEST PALM BEACH FLORIDA | | | DATE: OCTOBER 13, 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA | | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | | AMENDMENTS. BELOW IS A LIST OF ITEMS THAT HAVE BEEN | | | NOTED. | | | | | | 1] PROVIDE A FIRE PENETRATION DETAIL FOR FIRE WALLS, | | | SMOKE BARRIERS, AND FIRE PARTITIONS. SHOW THROUGH | | | PENETRATION DETAILS FOR ALL NEWLY INSTALLED RUNS. | | | FBC-714 | | | | | | 2] IDENTIFY FIRE & SMOKE RATING OF ANY WALLS TO BE | | | PENETRATED OR HAVE PENETRATIONS REMOVED WITHIN THE WORK | | | AREAS. FBC-704 | | | | | | 3] PROVIDE FPL LINE TO LINE AVAILABLE FAULT CURRENT TO | | | VERIFY AIC RATINGS AND SHORT-CIRCUIT CALCULATIONS OF | | | THE PROPOSED ELECTRICAL SYSTEM. NEC 110.9, 110.10, & | | | 110.24 | | | | | | 4] PROVIDE DOCUMENTATION OF SELECTIVE COORDINATION TIME | | | CURRENT CHARACTERISTICS CHARTS OF THE SERIES | | | COMBINATION. ENSURE GFP EQUIPMENT SHALL BE COORDINATED | | | IN A MATTER THAT THE LOAD SIDE SHALL REMAIN PASSIVE | | | DURING INTERRUPTION OF THE LINE SIDE CURRENT LIMITING | | | DEVICE. NEC 240.86, 517.17 | | | | | | 5] SHOW GFP PROTECTION OF EQUIPMENT ON THE ONE-LINE | | | DIAGRAMS FOR EACH DISCONNECT RATED 1000 AMPERES OR MORE | | | ON WYE SYSTEMS OF MORE THAN 150 VOLTS TO GROUND. NEC | | | 215.9,230.95, & 240.13 | | | | | | 6] ADD NOTES FOR DEDICATED EQUIPMENT SPACE EXTENDING | | | FROM THE FLOOR TO 6' ABOVE THE EQUIPMENT OR STRUCTURE | | | CEILINGS. NO FOREIGN SYSTEM PIPING ALLOWED IN THIS | | | ZONE. NEC 110.26(E)(1) | | | | | | 7] ADD NOTES FOR ELECT ROOMS WITH EQUIPMENT RATED OVER | | | 1200 AMPERES ENTRANCE & EGRESS DOORS SHALL BE MINIMUM | | | 24'' WIDE 6'6'' HIGH WITH PANIC HARDWARE DEVICES. | | | DEMOLITIONS OF WALLS IN ORDER TO INSTALL EQUIPMENT WILL | | | REQUIRE A BUILDING PERMIT. NEC 110.26(C)(2)(3 | | | | | | 8] NEC 110.16 ARC-FLASH HAZARD WARNING: ELECTRICAL | | | EQUIPMENT IN OTHER THAN DWELLING UNITS LIKELY TO | | | REQUIRE SERVICED WHILE ENERGIZED SHALL BE FIELD MARKED | | | TO WARN AGAINST POTENTIAL ARC-FAULT HAZARDS. | | | | | | 9] SHOW COMPLIANCE WITH NEC 110.22 A NOTE WILL | | | SUFFICE.TESTED OR ENGINEERED SERIES COMBINATION SYSTEMS | | | SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE THE | | | EQUIPMENT HAS BEEN APPLIED WITH SERIES COMBO RATING. | | | THE IDENTIFICATION SHOULD BE READILY ACCESSIBLE AND | | | SUITABLE FOR THE ENVIRONMENT INVOLVED. | | | | | | 10] SINCE MULTIPLE SERVICES ARE INVOLVED FOR SPECIAL | | | CONDITIONS AND CAPACITY REQUIREMENTS APPLY A PERMANENT | | | PLAQUE WITH A DIRECTORY DENOTING ALL OTHER SERVICE | | | DISCONNECTS SUPPLYING THE BUILDING. NEC 230.2(E) | | | | | | 11] CLARIFY WHY GENERATOR ROOM DOESN'T HAVE A FIRE | | | SUPPRESSION SYSTEM PER NEC 700.12 (GENERAL | | | REQUIREMENTS) | | | | | | 12] FEEDER 400N CANNOT EXCEED 2 % VOLTAGE DROP IN | | | ACCORDANCE WITH FBC-E SEC C405.7.3 | | | | | | 13] NEW T-GEN HAS WRONG SIZE PRIMARY CONDUCTORS FOR THE | | | TRANSFORMER, # 8 AWG CONDUCTOR IS ONLY GOOD FOR 50 AMP | | | PLEASE CORRECT ACCORDINGLY. | | | | | | 14] TAPS FROM COPPER TO ALUMINUM SHALL USE PROPERLY | | | IDENTIFIED SPLICING CONNECTION RATED FOR DISSIMILAR | | | METALS. ALL TERMINAL LUGS SHALL BE TIGHTENED TO LISTED | | | TORQUE AND MARKED VISIBLY TO THE FIELD INSPECTOR. NEC | | | 110.14 | | | | | | 15] SHOW TEMPORARY GUTTER SIZE TO COMPLY WITH NEC | | | 366,376,378 AND ALL TEMP CABLE WITH FINE STRANDED | | | CONDUCTORS SHALL BE TERMINATED PROPERLY AND APPROVED BY | | | INSPECTOR PER NEC 110.14 | | | | | | 16] PRIOR TO THE COMMENCEMENT OF ANY WORK ITS HIGHLY | | | RECOMMENDED TO CONTRACTOR TO REQUEST A MEETING WITH ALL | | | PARTIES INVOLVED AND THE BUILDING DEPARTMENT TO DISCUSS | | | CONSTRUCTION PHASING. | | | | | | 17] FIRE PUMPS SHALL BE SUBMITTED UNDER A SEPARATE | | | PERMIT IF BEING WORKED ON. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED ITEMS.WHEN RESUBMITTING, FOR A QUICKER RETURN | | | ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. IF | | | YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-06-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-31 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2017-02-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-02-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-02-24 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2017-02-27 12:35:46 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) REGARDING THE NEW DAY TANK, THERE IS INSUFFICIENT | | | DETAIL INDICATED TO DETERMINE OR ENSURE COMPLIANCE OF | | | THE DAY TANK WITH NFPA 30 AND OTHER APPLICABLE CODES. | | | | | | PLEASE COMPLETE A REVIEW AND PROVIDE AN DETAILED | | | NOTE/NARRATIVE. | | | | | | | | | | | | | | | 2) REGARDING THE MAIN GENERATOR, THERE IS INSUFFICIENT | | | DETAIL INDICATED TO DETERMINE OR ENSURE COMPLIANCE OF | | | ANY PROPOSED ACESSORY FULE TANK WITH NFPA 30 AND OTHER | | | APPLICABLE CODES. | | | | | | PLEASE COMPLETE A REVIEW AND PROVIDE AN DETAILED | | | NOTE/NARRATIVE. | | | | | | | | | | | | | | | 3) REGARDING THE MAIN GENERATOR LOCATION AND EXISTING | | | VAULT, THERE IS INSUFFICIENT DETAIL INDICATED TO | | | DETERMINE OR ENSURE COMPLIANCE WITH NFPA 110 AND OTHER | | | APPLICBALE CODES. | | | | | | IF THIS IS AN FP&L VAULT, DOES/WILL FP&L ALLOW THE | | | GENERATOR THIS CLOSE ? PLEASE PROVIDE AND APPLICABLE | | | REVIEW AND DETAILED NOTE/NARRATIVE. | | | | | | DOES THIS INSTALLATION MEET THE REQUIREMENTS OF NFPA | | | 110? PLEASE PROVIDE APPLICABLE DETAIL, INCLUDING | | | DIMENSIONS. | | | | | | DOES THE MANUFACTURES SPEC'S PROVIDE A MINIMUM | | | DIMENSION TO THE NEAREST STRUCTURE? | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-10-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-10-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-10-18 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2016-10-18 14:56:43 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET D100 - THERE IS AN INCORRECT YEAR REFERENCE TO | | | THE FFPC 5TH EDITION, IT SHOULD INDICATE 2012. | | | | | | PLEASE CORRECT AND ENSURE COMPLIANCE. | | | | | | | | | | | | 2) SHEET D101 - THERE IS NO INDICATIONS AND IT IS | | | UNCLEAR HOW THE LIFE SAFETY FIRE ALARM SYSTEM WILL BE | | | MAINTAINED THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | PLEASE PROVIDE A NOTE OR SHORT NARRATIVE IF AND HOW THE | | | FIRE ALARM WILL BE MAINTAINED THROUGHOUT THE HOSPITAL. | | | | | | PER NFPA 101, CHAPTER 9 A FIRE WATCH SHALL BE | | | MAINTAINED ANY TIME A SYSTEM IS DOWN FOR MORE THAN 4 | | | HOURS. | | | | | | 9.6.1.6* WHERE A REQUIRED FIRE ALARM SYSTEM IS OUT OF | | | SERVICE FOR MORE THAN 4 HOURS IN A 24-HOUR PERIOD, THE | | | AUTHORITY HAVING JURISDICTION SHALL BE NOTIFIED, AND | | | THE BUILDING SHALL BE EVACUATED, OR AN APPROVED FIRE | | | WATCH SHALL BE PROVIDED FOR ALL | | | PARTIES LEFT UNPROTECTED BY THE SHUTDOWN UNTIL THE FIRE | | | ALARM SYSTEM HAS BEEN RETURNED TO SERVICE. | | | | | | | | | | | | 3) SHEET D 301 - THERE IS AN INDICATION OF A NEW | | | GENERATOR. ANY NEW GENERATOR INSTALLATION IS NOT | | | APPROVED UNDER THIS PERMIT. | | | | | | PLEASE PROVIDE A NOTE INDICATING THAT THE NEW GENERATOR | | | SHALL BE UNDER SEPARATE PERMIT. | | | | | | | | | | | | 4) SHEET D304 - THERE IS FIRE ALARM WORK INDICATED IN | | | THE NOTES SECTION. ANY FIRE ALARM WORK SHALL BE | | | COMPLETED BY QUALIFIED LIOFE SAFETY CONTRACTORS UNDER | | | SEPARATE SHOP DRAWINGS. | | | | | | PLEASE PROVIDE A NOTE INDICATING AND ACKNOWLEDGING THE | | | ABOVE. | | | | | | | | | | | | 5) SHEET D 306 - THERE IS FIRE SPRINKLER WORK | | | INDICATED. ANY FIRE SPRINKLER WORK SHALL BE COMPLETED | | | BY QUALIFIED LIFE SAFETY CONTRACTORS UNDER SEPARATE | | | SHOP DRAWINGS. | | | | | | PLEASE PROVIDE A NOTE INDICATING AND ACKNOWLEDGING THE | | | ABOVE. | | | | | | | | | | | | 6) SHEET 307 - THERE IS AN INDICATION OF A NEW | | | GENERATOR. ANY NEW GENERATOR INSTALLATION IS NOT | | | APPROVED UNDER THIS PERMIT. | | | | | | PLEASE PROVIDE A NOTE INDICATING THAT THE NEW GENERATOR | | | SHALL BE UNDER SEPARATE PERMIT. | | | | | | | | | | | | 7) SHEET 310, D322 AND OTHER APPLICABLE GENERATOR | | | EXHAUST SHEETS - THE NEW GENERATOR(S) EXHAUST APPEARS | | | TO IN AN AREA OF MULTIPLE WINDOWS AND INHABITABLE | | | AREAS. | | | | | | PLEASE PROVIDE A DETAILED REVIEW INDICATING COMPLIANCE | | | WITH NFPA 110. CHAPTER 7 | | | | | | 7.10 EXHAUST SYSTEM. | | | 7.10.1 THE EXHAUST SYSTEM EQUIPMENT AND INSTALLATION, | | | INCLUDING PIPING, MUFFLER, AND RELATED ACCESSORIES, | | | SHALL BE IN ACCORDANCE WITH NFPA37, STANDARD FOR THE | | | INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES | | | AND GAS TURBINES, AND OTHER APPLICABLE STANDARDS. | | | | | | 7.10.2 EXHAUST SYSTEM INSTALLATION SHALL BE GASTIGHT TO | | | PREVENT EXHAUST GAS FUMES FROM ENTERING INHABITED ROOMS | | | OR BUILDINGS AND TERMINATE IN SUCH A MANNER THAT TOXIC | | | FUMES CANNOT REENTER A BUILDING OR STRUCTURE, | | | PARTICULARLY THROUGH WINDOWS, | | | AIR VENTILATION INLETS, OR THE ENGINE AIR-INTAKE | | | SYSTEM. | | | | | | | | | | | | 8) PLEASE PROVIDE PLAN SHEET REVISION CLOUDS OR | | | NUMBERED NARRATIVE RESPONSES TO THE ABOVE. | | | | | | | | | | | | | | | 9) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
F |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-06-20 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-05-24 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-03-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-02-16 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-10-24 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2016-09-21 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2016-09-22 10:02:46 | 10/13/16 - C03 | | | ROUTED TO ELECTRICAL INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-31 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-31 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-02-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-23 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-23 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2017-02-23 09:04:35 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16090809 | | | 2/23/17 | | | | | | 1) DWG NO 500: IDENTIFY THE DAY TANK ON THE DRAWINGS | | | AND SHOW THE VENT PIPING RUNS AND DISCHARGE LOCATIONS- | | | SEE SECTION 1305.7 . PLEASE PROVIDE THE TYPES AND SIZES | | | OF VENT PIPES. | | | | | | 2) DWG NO 500: PROVIDE THE CLEARANCE DISTANCE | | | MEASUREMENTS FOR THE GENERATOR COMBUSTION AND RADIATOR | | | EXHAUST OUTLETS TO GRADE- SEE SECTION 501.3.1 | | | | | | 3) CLARIFY THE SCOPE OF WORK PERTAINING TO THE LARGE | | | INDOOR GENERATOR FUEL TANKS. IT APPEARS FROM THE | | | DRAWINGS THAT EITHER ONE OR TWO NEW TANKS ARE BEING | | | INSTALLED IN THE EQUIPMENT ROOM ADJACENT TO THE | | | GENERATOR ROOM. PROVIDE SPECIFICATIONS ON THE PLAN AND | | | SUBMIT PRODUCT DATA SHEETS FOR THE TANKS. REVIEW | | | CHAPTER 9 NFPA 30 AND SHOW COMPLIANCE WITH ALL | | | APPLICABLE SECTIONS FOR INDOOR STORAGE OF FLAMMABLE AND | | | COMBUSTIBLE LIQUIDS. | | | | | | 4) THE SUBMITTED NOA'S FOR THE AIR INTAKE AND THE | | | EXHAUST LOUVERS DO NOT INCLUDE THE INSTALLATION | | | DRAWINGS- PLEASE PROVIDE COMPLETE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-10-13 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-10-13 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2016-10-13 14:46:39 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16090809 | | | 10/13/16 | | | | | | 1) DWG NO. D500: PROVIDE AC COOLING AND HEATING | | | CALCULATIONS FOR THE NEW MINI-SPLIT SYSTEMS. | | | | | | 2) D500: CLARIFY THE SCOPE OF WORK FOR THE GENERATOR- | | | NEW OR RELOCATED? A) PROVIDE AN EQUIPMENT SCHEDULE THAT | | | INDICATES THE MAKE AND MODEL OF THE GNERATOR, | | | ELECTRICAL DATA, FUEL TYPE, ETC. B) PROVIDE AN ENLARGED | | | DIMENSIONED DRAWING AND SCHEMATIC, WITH DETAILS AND | | | NOTES IDENTIFYING THE TYPE AND SIZE OF EXHAUST VENTING, | | | AND FUEL PIPING. CLARIFY HOW FUEL IS BEING STORED AND | | | SUPPLIED TO THE GENERATOR AND WHAT THE TYPE OF FUEL IS- | | | DIESEL, GAS, BOTH? C) REFER TO SECTION 501.3.1 AND SHOW | | | ALL REQUIRED CLEARANCE DISTANCE MEASUREMENTS FOR THE | | | SIDEWALL RADIATOR AND GENERATOR EXHAUST OUTLETS. D) | | | SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE GENERATOR | | | WITH SHOP DRAWING APPROVAL SIGNATURE BY THE ENGINEER OF | | | RECORD. | | | | | | 3) D500: THE WIND LOAD CALCULATIONS AND FASTENING NOTES | | | FOR A ROOFTOP AC STAND DO NOT CORRELATE WITH THE | | | PROPOSED GROUND MOUNTED CONDENSER INSTALLATIONS- PLEASE | | | PROVIDE CORRECT THE CALCULATIONS AND NOTES. | | | | | | 4) SUBMIT FL. PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S | | | FOR THE GREENHECK AIR INTAKE LOUVER, AND THE RUSKIN | | | EXHAUST LOUVER. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | 2016-10-13 12:57:22 | PLEASE DETERMIN IF THIS NEEDS A BUILDING STOP, IF SO | | | ADD AND MOVE IT ON. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2017-08-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-08-01 |
Time |
15:47 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2017-08-01 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2017-08-01 15:48:26 | REPLACEMENT SHRUBS REQUIRED - 24 INCHES TALL, 24 ON | | | CENTER, RECOMMEND COCOPLUM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2017-06-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-06-07 |
Time |
11:42 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2017-06-07 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2017-06-07 11:42:09 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) REPEAT COMMENT: THE DEMOLITION OF THE EXISTING | | | GENERATOR AND THE CONSTRUCTION OF A NEW GENERATOR PAD | | | AND LOCATING A 1,000 KW GENERATOR ON THE PAD REQUIRES | | | AN AMENDMENT TO THE WEST PALM HOSPITAL COMMUNITY | | | SERVICE PLANNED DEVELOPMENT SITE PLAN. A MINOR PLANNED | | | DEVELOPMENT APPLICATION SHALL BE FILED WITH THE | | | PLANNING DIVISION AND RECEIVE APPROVAL, PRIOR TO THE | | | ZONING APPROVAL OF THIS PERMIT. | | | | | | 2) THE EXISTING SHRUBS ARE STILL REQUIRED TO BE | | | RELOCATED AND MAY NOT BE REMOVED FROM THE SITE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-03-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-03-07 |
Time |
14:26 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2017-03-07 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2017-03-07 14:59:32 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) REPEAT COMMENT: THE DEMOLITION OF THE EXISTING | | | GENERATOR AND THE CONSTRUCTION OF A NEW GENERATOR PAD | | | AND LOCATING A 1,000 KW GENERATOR ON THE PAD REQUIRES | | | AN AMENDMENT TO THE WEST PALM HOSPITAL COMMUNITY | | | SERVICE PLANNED DEVELOPMENT SITE PLAN. A MINOR PLANNED | | | DEVELOPMENT APPLICATION SHALL BE FILED WITH THE | | | PLANNING DIVISION AND RECEIVE APPROVAL, PRIOR TO THE | | | ZONING APPROVAL OF THIS PERMIT. | | | | | | 2) WHILE THE GENERATOR ITSELF IS ENCLOSED IN A HOUSING, | | | THE FUELING ASSEMBLY IS EXPOSED ON THE END OF THE | | | GENERATOR, WHICH REQUIRES THAT THERE BE A SCREEN WALL | | | WITH HEDGES CONSTRUCTED ON THE NORTH AND WEST SIDES OF | | | THE GENERATOR (THE EAST AND SOUTH ARE SCREENED BY THE | | | EXISTING BUILDING WALLS). A PERMIT FOR THE SCREEN WALL | | | AND HEDGES SHALL BE SUBMITTED, APPROVED AND CONSTRUCTED | | | PRIOR TO THE FINAL PERMIT INSPECTION FOR THE GENERATOR. | | | THE SCREENING NEEDS TO BE INCLUDED ON THE MINOR PLANNED | | | DEVELOPMENT AMENDMENT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-10-24 |
Time |
14:31 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2016-10-24 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2016-10-24 16:55:31 | FAILED | | | | | | 1) THE DEMOLITION OF THE EXISTING GENERATOR AND THE | | | CONSTRUCTION OF A NEW GENERATOR PAD AND LOCATING A | | | 1,000 KW GENERATOR ON THE PAD REQUIRES AN AMENDMENT TO | | | THE WEST PALM HOSPITAL COMMUNITY SERVICE PLANNED | | | DEVELOPMENT SITE PLAN. A MINOR PLANNED DEVELOPMENT | | | APPLICATION SHALL BE FILED WITH THE PLANNING DIVISION | | | AND RECEIVE APPROVAL, PRIOR TO THE ZONING APPROVAL OF | | | THIS PERMIT. | | | | | | 2) COMPARING THE PROPOSED GENERATOR PAD LAYOUT AND THE | | | EXISTING SITE CONDITIONS INDICATE THAT THERE WILL BE | | | SHRUBS AND POSSIBLE A TREE IMPACTED BY THE PROPOSED | | | PAD. LANDSCAPE MITIGATION SHALL BE INCLUDED WITH THE | | | MINOR PLANNED DEVELOPMENT AMENDMENT. | | | | | | 3) PROVIDE THE FULL HEIGHT OF THE GENERATOR. | | | | | | 4) PROVIDE HOW THE FULL HEIGHT OF THE GENERATOR WILL BE | | | SCREENED. | | | | | | 5) PLEASE PROVIDE DETAILS ON HOW CU-2 SHOWN ON DRAWING | | | D500 WILL BE SCREENED FROM VIEW. | | | | | | 6) PLEASE VERIFY THAT THE FOUR FOOT EIGHT INCH HEIGHT | | | OF THE PROTECTIVE SCREEN WALL FOR CU-1 SHOWN ON DRAWING | | | D500 WILL BE OF SUFFICIENT HEIGHT TO SCREEN THE FULL | | | HEIGHT OF CU-1. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
|