Plan Review Details - Permit 16090801
Plan Review Stops For Permit 16090801
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-11-07 Cont ID  
Sent By   Date   Time 14:30 Rev Time 0.00
Received By   Date 2016-11-07 Time 13:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-18 Cont ID  
Sent By jwitmer Date 2016-10-18 Time 15:08 Rev Time 0.00
Received By jwitmer Date 2016-10-18 Time 14:00 Sent To  
Notes
2016-10-18 15:08:26BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16090801
 ADD: 711 VILLAGE BLVD. SUITE : 102
 CONT: SKY HIGH CONSTRUCTION
 TEL: 305-389-6292
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. OCT. 18/2016
 ACTION: DENIED
  
 1) SHEET A-2 INDICATES NEW STOREFRONT ELEMENTS,
 STOREFRONT GLAZING, DROP BOX AND 24 HOUR PICK-UP DOOR.
 PLEASE PROVIDE COMPLIANCE WITH 2014 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS
  
 2) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) NONE OF THE SUBMITTED PLANS SUBMITTED PROVIDE WIND
 DESIGN CRITERIA IN COMPLIANCE WITH THE 2014 FBC-B
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 3.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 3.2. RISK CATEGORY.
  
 3.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
  
 3.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 3.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-09-28 Cont ID  
Sent By vperez Date 2016-09-28 Time 10:06 Rev Time 0.00
Received By vperez Date 2016-09-27 Time 12:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-10-03 Cont ID  
Sent By scaldero Date 2016-10-03 Time 14:53 Rev Time 0.00
Received By scaldero Date 2016-10-03 Time 14:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-07 Cont ID  
Sent By   Date 2016-11-07 Time   Rev Time 0.00
Received By lmarchan Date 2016-10-28 Time 12:51 Sent To  
Notes
2016-10-31 12:51:56RESUB ROUTED TO GJOHNSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-24 Cont ID  
Sent By jwitmer Date 2016-10-24 Time 13:02 Rev Time 0.00
Received By gjohnson Date 2016-09-21 Time 09:51 Sent To  
Notes
2016-09-22 09:52:06B09

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-10-18 Cont ID  
Sent By jwitmer Date 2016-10-18 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2016-10-18 Time 14:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-09-28 Cont ID  
Sent By ccole Date 2016-09-28 Time 16:06 Rev Time 0.00
Received By ccole Date 2016-09-28 Time 16:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-11-07 Cont ID  
Sent By gjohnson Date 2016-11-07 Time 11:02 Rev Time 0.00
Received By gjohnson Date 2016-11-07 Time 11:02 Sent To  
Notes
2016-11-07 11:02:44PLUMBING PROVISO:
 1. TWO DRINKING FOUNTAINS REQUIRED. PER FBC ACC 211.2
 MINIMUM NUMBER.
 NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7. FBC PL [B] 410.2 MINIMUM NUMBER.
 WHERE DRINKING FOUNTAINS ARE REQUIRED, NOT FEWER THAN
 TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS FOR PEOPLE
 WHO USE A WHEELCHAIR AND ONE DRINKING FOUNTAIN SHALL
 COMPLY WITH THE REQUIREMENTS FOR STANDING PERSONS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-10-24 Cont ID  
Sent By gjohnson Date 2016-10-24 Time 12:14 Rev Time 0.00
Received By gjohnson Date 2016-10-24 Time 09:25 Sent To  
Notes
2016-10-24 13:02:251ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. GRAB BARS SHALL BE MEASURED FROM TOP OF GRIPPING TO
 FINISHED FLOOR. PER FBC ACC 609.4
  
 2.TOILET PAPER DISPENSER SHALL BE 7"- 9" FROM FRONT OF
 TOILET TO CENTERLINE OF DISPENSER. PER FBC ACC 604.7
  
 3. INDICATE TYPE OF PIPING USED FOR COMPRESSED AIR. PER
 WPB AMEND TO GBC 107.2.1
  
 4. SERVICE SINK REQUIRED PER FBC PL 403.1
  
 5. TEMPERED WATER REQUIRED AT LAVATORY SUPPLIED BY
 TEMPERATURE LIMITING DEVICE. PER FBC PL 416.5 / 607.1.1