|
 |
 |
 |
 |
 |
Plan Review Details - Permit 16090794
| Plan Review Stops For Permit 16090794 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-10-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-10-14 |
Time |
05:58 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-10-11 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2016-10-11 15:31:53 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-24 |
Time |
02:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-21 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2016-09-22 09:36:29 | ROUTED TO PLUMBING <5K |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-10-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-10-14 |
Time |
05:58 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-10-14 |
Time |
05:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-09-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-24 |
Time |
02:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-24 |
Time |
02:18 |
Sent To |
|
|
| Notes |
| 2016-09-24 02:24:30 | 1) SUBMIT SIZING CALCULATIONS FOR THE SIZING OF THIS | | | GREASE TRAP. 2014 FPC SEC.1003.2, 1003.3.4. | | | 2) THESE DEVICES ARE USUALLY EQUIPPED WITH FLOW CONTROL | | | DEVICES THAT ARE VENTED. THIS IS NOT SHOWN ON THE | | | PLANS. SUBMIT THE INSTALLATION DETAILS FROM THE | | | INSTALLATION MANUAL FOR THIS DEVICE.WPB AMEND. TO FBC | | | SEC.107.2.1, 1003.3.4.2. | | | 3) PLANS DONE IN PENCIL CANNOT BE ACCEPTED AS CHANGES | | | CAN BE MADE AFTER APPROVAL OF THE PLANS. | | | 4) PLEASE CLARIFY THE TYPE OF FIXTURE DISCHARGING INTO | | | THE GREASE INTERCEPTOR. IT APPEARS TO BE A 3 | | | COMPARTMENT SINK. IS IT NEW OR EXISTING? IF NEW, SUBMIT | | | A WATER RISER ALSO. WPB AMEND. TO FBC SEC. 107.3.5.1.3. | | | 5) INDICATE ON THE PLANS IF THIS INTERCEPTOR IS | | | REPLACING AN EXISTING UNIT OR IS IT A NEW | | | INSTALLATION.IF THE INTERCEPTOR AND SINK ARE NEW SUBMIT | | | A FLOOR PLAN SHOWING THE LOCATION OF THE SINK & | | | INTERCEPTOR. WPB AMEND. TO FBC SEC.107.2.1, | | | 6) IF THE SINK IS NEW, INDICATE ON THE PLAN WHERE THE | | | THE 2 INCH DRAIN IS CONNECTING TO THE EXISTING SANITARY | | | SYSTEM. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |