Plan Review Details - Permit 16090649
| Plan Review Stops For Permit 16090649 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-12-16 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-12-16 |
Time |
10:11 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-11-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-11-23 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-11-23 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2016-11-23 14:40:01 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | 1. PLANS TO BE SIGNED AND SEALED BY LICENSED DESIGN | | | PROFESSIONAL. | | | 2. PLANS TO BE SUBMITTED IN DUPLICATE. | | | 3. PROVIDE WRITTEN ACCEPTANCE FROM ROOF SYSTEM | | | MANUFACTURER PRIOR TO INSTALLATION OF OMG POWER GRIP | | | FASTENERS. FAILURE TO DO SO COULD VOID THE ROOF | | | WARRANTY. ( SEE DIRECTIONS ON PG 26 OF 26 OF | | | MANUFACTURERS INSTALLATION INSTRUCTIONS). | | | | | | PURSUANT TO FBC 107.1, AND FS 481.229 (1) (C), AS THIS | | | DESIGN EXCEEDS $25,000.00 IN VALUE, THE DESIGN MUST BE | | | PREPARED BY A LICENSED PROFESSIONAL PURSUANT TO FS 481. | | | SEE BELOW: | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. THE CONSTRUCTION DOCUMENTS SHALL BE | | | PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE | | | REQUIRED BY CHAPTER 471, FLORIDA STATUTES& 61G15 | | | FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA | | | STATUTES& 61G1 FLORIDA ADMINISTRATIVE CODE. WHERE | | | SPECIAL CONDITIONS EXIST, THE BUILDING OFFICIAL IS | | | AUTHORIZED TO REQUIRE ADDITIONAL CONSTRUCTION DOCUMENTS | | | TO BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL. ELECTRONIC MEDIA | | | DOCUMENTS SHALL BE SUBMITTED WHEN REQUIRED BY THE | | | BUILDING OFFICIAL, AND MAY REQUIRE ONLY ONE SET OF | | | SUBMITTALS. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-09-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-28 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-28 |
Time |
10:27 |
Sent To |
E |
|
| Notes |
| 2016-09-28 10:33:03 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | 1. REQUIRES LETTER FROM OWNER THAT THEY ACKNOWLEDGE THE | | | INSTALLATION OF THIS PRODUCT (POWER GRIP PLUS) MAY VOID | | | THE ROOF WARRANTY PER MANUFACTURERS INSTALLATION | | | INSTRUCTIONS ON PG 26 OF 26. | | | 2. MULTIPLE PLAN SHEETS ILLEGIBLE. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-12-19 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-12-19 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-11-23 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-11-23 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-11-23 |
Time |
10:48 |
Sent To |
B |
|
| Notes |
| 2016-11-23 14:03:03 | JOB PERMIT NUMBER: 16090649 | | | JOB ADDRESS: 444 BUNKER RD | | | WEST PALM BEACH FLORIDA (COMMERCIAL SOLAR SYSTEM) | | | DATE: NOVEMBER 23, 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA | | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | | AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED. | | | | | | 1] PLANS REQUIRE SIGNING & SEALING BY AN ELECTRICAL | | | ENGINEER IN ACCORDANCE WITH FS 471 | | | | | | 2] PROVIDE FPL AVAILABLE FAULT CURRENT LETTER & SHOW | | | AIC CALCULATIONS TO VERIFY SHORT CIRCUIT RATINGS OF | | | ELECTRICAL EQUIPMENT. NEC 110.24, 110.10, 110.9 | | | | | | 3] SUBMITTAL DOCUMENTS SHALL BE SUBMITTED IN TWO OR | | | MORE SETS WITH EACH PERMIT APPLICATION. FBC 107 | | | | | | 4] PLEASE COMPLY WITH GROUNDING & BONDING PROVISIONS | | | PER NEC 250.24, 250.28, 250.30. VERIFY GROUNDED | | | CONDUCTOR IS'T ATTACHED TO ENCLOSURES ON LOAD SIDE | | | CONNECTIONS, VERIFY EQUIPMENT GROUNDING CONDUCTOR | | | SYSTEM IS IN PLACE TO CREATE AN EFFECTIVE GROUND | | | CURRENT PATH, LASTLY VERIFY SEPARATELY DERIVED SYSTEMS | | | IS PROPERLY GROUNDED WITH AN ELECTRODE & BONDED AS TO | | | PREVENT OBJECTIONABLE CURRENT. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER | | | RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES | | | WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER | | | QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME | | | DIRECTLY. | | | | | | 1ST REVIEW FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-09-29 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-29 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-29 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2016-09-29 08:59:31 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1] FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | | | | 2] FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. ( HARD TO READ ) | | | | | | 3] PROVIDE A ONE-LINE DIAGRAM SHOWING IF THE PV SYSTEM | | | IS UTILITY GRID TIED AND IF SO, SHOW IF ITS ON THE | | | SUPPLY SIDE OR LOAD SIDE OF THE ELECTRICAL SYSTEM. | | | INCLUDE ALL REQUIRED SIGNAGE, SHOW ALL EQUIPMENT | | | LOCATION, WIRE AND CONDUIT SIZES. | | | | | | 4] PROVIDE MANUFACTURE SPECS. | | | | | | 5] ELECTRICAL SUB PERMIT REQUIRED | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-12-19 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-12-13 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2016-12-14 14:53:26 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-11-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-11-23 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-10-24 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2016-10-24 12:50:46 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-29 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-29 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-19 |
Time |
10:34 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-12-15 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-12-15 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-12-14 |
Time |
17:06 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-10-28 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-10-28 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-10-25 |
Time |
17:13 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-09-22 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-29 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-09-19 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2016-09-22 10:52:18 | 9/22/16- FAILED | | | | | | PLEASE PROVIDE A SITE PLAN SHOWING WHERE ON THE ROOF | | | THE SOLAR PANELS ARE GOING. | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|
|