| Plan Review Stops For Permit 16090628 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-25 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-24 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2016-10-25 16:05:03 | APPROVED WITH EXCEPTIONS. | | | | | | BUILDING PROVISO | | | | | | 1) FBC-R302.5.1 REQUIRES A SELF-CLOSING DEVICE ON THE | | | DOOR FROM THE GARAGE TO THE RESIDENCE. | | | | | | 2) SUBMIT TWO SETS OF TRUSS DRAWINGS AND LAYOUTS WITH | | | THE ORIGINAL HANDWRITTEN SIGNATURE AND SEAL OF THE | | | TRUSS ENGINEER AS REQUIRED BY FAC 61G15-23.002. COPIES | | | AND OTHER FASCIMILES ARE NOT ACCEPTABLE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-09-19 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-19 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-19 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2016-09-19 12:26:38 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | PASSED WITH THE FOLLOWING PROVISO'S | | | | | | 1] FPL LETTER REQUIRED ON-SITE FOR FIELD INSPECTOR | | | REVIEW. INFORMATION NEEDED TO VERIFY MINIMUM AIC & | | | SHORT CIRCUIT RATINGS, PLANS DIDN'T INCLUDE TRANSFORMER | | | SECONDARY IMPEDIANCE. | | | | | | 2] PROVIDE A SWITCHED CONTROLLED LIGHTING OUTLET BY THE | | | ATTIC ENTRANCE LOCATED NEAR ANY EQUIPMENT REQUIRING | | | SERVICING. NEC 210.70(3) | | | | | | 3] INSTALL AN INTERSYSTEM BONDING TERMINAL. NEC 250.94 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-12 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2017-04-13 11:26:17 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-10-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-25 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-09-16 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-13 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2017-04-13 18:08:26 | MU2017-9626 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-24 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-24 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2016-10-24 18:20:42 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2016-10-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2016-10-21 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2016-10-21 |
Time |
14:47 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-10-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-10-11 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-09-30 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-10-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-25 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-25 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2016-10-25 16:59:10 | TAMKO ASPHALT SHINGLES FL1956.4 HERITAGE 30 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-09-23 |
|
|
Cont ID |
|
| Sent By |
nwair |
Date |
2016-09-23 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-09-23 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2016-09-23 17:10:17 | 9/23/16- PASSED | | | | | | SF-7 NON-HISTORIC DISTRICT | | | | | | NO TREES BEING REMOVED | | | FRONT SETBACK IS 25FT. MEETING THE 25FT. FRONT SETBACK | | | REQUIREMENT | | | REAR SETBACK IS 38.32FT. MEETING THE 15FT. REAR SETBACK | | | REQUIREMENT. | | | SIDE SETBACK IS 8.33 ON BOTH SIDES MEETING THE 5FT. | | | MINIMUM 15FT. TOTAL | | | A/C UNIT IS NOT 4FT. INTO A REQUIRED SETBACK | | | REQUIRES A DRIVEWAY PERMIT. | | | FRONT SETBACK MUST HAVE 75% OR 1,000SQFT. OF GREEN | | | SPACE | | | HOUSE DOES NOT EXCEED 30FT. IN HEIGHT BEING ONE STORY | | | HOUSE HAS ONE(1)KITCHEN | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|