Plan Review Details - Permit 16090627
Plan Review Stops For Permit 16090627
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-24 Cont ID  
Sent By rmcdouga Date 2016-10-24 Time 16:33 Rev Time 0.00
Received By rmcdouga Date 2016-10-24 Time 07:57 Sent To  
Notes
2016-10-24 11:33:39PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC ENERGY CONSERVATION - SECT. 103.1.1.2 CODE
 COMPLIANCE CERTIFICATION.
 THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR
 TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION. FBC ENERGY CONSERVATION SECTIONS
 R101.5.1.1.1 OR R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY
 COMPLIANCE FORMS AS REQUIRED.
  
 2) THE SOIL REPORT THAT WAS SUBMITTED FROM ALLTERRA
 ENGINEERING & TESTING STATES THAT A 24 INCH WIDE
 CONTINOUS FOOTING IS REQUIRED TO ACHIEVE A 2500 PSF
 ALLOWABLE BEARING PRESSURE. THE PLANS SHOW AN 18" WIDE
 MONOLITHIC FOOTING. PLEASE REVIEW THE REPORT TO INSURE
 THAT THE PROPOSED FOOTING WILL BE ADEQUATE. FBC 107.2.1
  
 3) PROVIDE A LINTEL SCHEDULE ON THE PLANS. FBC 107.2.1
  
 4) SHOW COMPLIANCE WITH FBC - R905.2.2 SLOPE. ASPHALT
 SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF TWO UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER. FOR
 ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (2:12) UP TO FOUR UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING
 WITH ASTM D 226, TYPE I OR TYPE II, ASTM D 4869, TYPE I
 OR TYPE II OR ASTM D 6757 IS REQUIRED IN ACCORDANCE
 WITH SECTION R905.2.7.
  
 5) FBC R403.1.4 REQUIRES EXTERIOR FOOTINGS TO BE A
 MINIMUM OF 12 INCHES BELOW GRADE. SECTION B ON SHEET 5
 SHOWS A 16" THICK FOOTING WITH 8" ABOVE GRADE WHICH
 LEAVES ONLY 8" BELOW GRADE.
  
 6) THE PRODUCT APPROVALS FOR THE GAF ASPHALT SHINGLES
 MIAMI DADE NOA NO. 14-1022.16 ARE MISSING SOME PAGES
 AND THE ONES THAT WERE SUBMITTED ARE MISSING
 INFORMATION AT THE BOTTOM OF THE PAGES. SUBMIT COMPLETE
 PRODUCT APPROVALS. FBC 107.2.1
  
 7) THE PRODUCT APPROVALS FOR THE YALE OGRON FRENCH
 DOORS ARE MISSING SOME PAGES AND THE ONES THAT WERE
 SUBMITTED ARE MISSING INFORMATION AT THE BOTTOM AND
 SIDES OF THE PAGES. SUBMIT COMPLETE PRODUCT APPROVALS.
 FBC 107.2.1
  
 8) TWO SETS OF PRODUCT APPROVALS ARE REQUIRED PER FBC
 107.1. SUBMIT AN ADDITIONAL SET OF PRODUCT APPROVALS
 FOR THE CUSTOM WINDOW SYSTEMS INC. SINGLE HUNG WINDOWS,
 FL15699-R2.
  
 9) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-09-19 Cont ID  
Sent By mvaldes Date 2016-09-19 Time 10:42 Rev Time 0.00
Received By mvaldes Date 2016-09-19 Time 09:34 Sent To  
Notes
2016-09-19 10:53:56REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 1] CLARIFY "EXISTING TO NEW" SERVICE RISER-DIAGRAM
 CONFIGURATION. SPECIFY WIRE & CONDUIT SIZES, GROUNDING
 DETAIL TO SHOW BONDING TO WATER PIPE, OR METAL OF
 BUILDING. FBC 107.3.5.3
  
 2] PROVIDE A DOUBLE POLE SWITCH DISCONNECT WITHIN SIGHT
 OF THE MINI-SPLIT AND LABEL EXTERIOR OUTLET GFCI
 "WR/WP". FBC-R_E4101.5 & FBC-R_E4002.10
  
 3] ADD A NOTE FOR SMOKE ALARMS PER FBC-R 314 & 315
  
 4] ADD A NOTE FOR TAMPER-RESISTANT RECEPTACLES PER
 FBC-R_E4002.14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-24 Cont ID  
Sent By rmcdouga Date 2016-10-24 Time 16:33 Rev Time 0.00
Received By rmcdouga Date 2016-09-16 Time 13:45 Sent To  
Notes
2016-09-16 13:45:38R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-10-24 Cont ID  
Sent By rmcdouga Date 2016-10-24 Time 08:07 Rev Time 0.00
Received By rmcdouga Date 2016-10-24 Time 08:07 Sent To  
Notes
2016-10-24 08:07:43BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-21 Cont ID  
Sent By hmoser Date 2016-10-21 Time 15:05 Rev Time 0.00
Received By hmoser Date 2016-10-21 Time 15:05 Sent To  
Notes
2016-10-21 15:09:14PLAN DENIED
 PROVIDE ENERGY CALCULATIONS FOR ADDITION. PER SECTION
 R 403.6 HEATING AND COOLING EQUIPMENT (MANDATORY)
 2014 FLORIDA ENERGY CODE
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-10-20 Cont ID  
Sent By gjohnson Date 2016-10-20 Time 12:24 Rev Time 0.00
Received By gjohnson Date 2016-10-20 Time 12:24 Sent To  
Notes
2016-10-20 12:40:091ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE PLUMBING RISER DIAGRAM. PER WPB AMEND
 TO FBC 107.3.5.3(11)
  
 2. THE P-TRAP AND STAND PIPE FOR WASHING MACHINE IS
 REQUIRED TO BE MIN OF 2". PER FBC RES TABLE P3201.7
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-10-04 Cont ID  
Sent By ajones Date 2016-10-04 Time 11:53 Rev Time 0.00
Received By ajones Date 2016-10-04 Time 11:53 Sent To  
Notes
2016-10-04 11:57:3610/4/16- FAILED. WHAT IS THE ADDITION GOING TO BE USED
 FOR? WHY IS AN ADDITIONAL ELECTRIC METER NEEDED?
  
 ANGELLA VANN
 561-317-8177
 [email protected]