Plan Review Details - Permit 16090626
Plan Review Stops For Permit 16090626
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-01-18 Cont ID  
Sent By jwitmer Date 2017-01-18 Time 10:28 Rev Time 0.00
Received By jwitmer Date 2017-01-18 Time 09:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-12-30 Cont ID  
Sent By jwitmer Date 2016-12-30 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2016-12-30 Time 05:58 Sent To  
Notes
2016-12-30 06:45:38BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16090626
 ADD: 1721 PALM BEACH LAKES BLVD. SUITE # E419
 CONT: AIR SOUTH MECHANICAL INC.
 TEL: 305-828-9400
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW.
 DATE: FRI. DEC. 30/ 2016
 ACTION: DENIED
  
 1) PLEASE NOTE THE 1ST REVIEW WAS PASSED BELIEVING THIS
 TO BE A INDOOR COOLER/ FREEZER, THIS IS NOT THE CASE.
 IT APPEARS THAT INTERNATIONAL CODE STORAGE HAS HAD
 TESTING COMPLETED AND REVIEWED BY THE STATE OF FLORIDA
 FOR A STATEWIDE PRODUCT APPROVAL. PLEASE NOTE TO DATE
 NO FLORIDA COVERSHEET HAS BEEN PROVIDED WITH A CURRENT
 FLORIDA APPROVAL NUMBER. IF GOING THROUGH THE PROCESS
 AND NOT AFFIRMED BY THE STATE THEN LET US KNOW WE CAN
 E-MAIL THE FORMS FOR A LOCAL PRODUCT APPROVAL. THE CITY
 OF WEST PALM BEACH USES THE SAME 10 CRITERIA AS THE
 STATE BUT MUST BE SUBMITTED ON THE CITY FORMS FOR
 REVIEW BY THE BUILDING OFFICIAL.
 2014 FBC-B 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA
 ADMINISTRATIVE CODE 61G20-3.004 OPTIONAL STATEWIDE
 APPROVAL. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)((G) EXTERIOR COOLER& FREEZERS.
  
 2) SHEET K-3 DOES NOT PROVIDE WHO IS THE DESIGNER OF
 RECORD FOR THIS SHEET. IN THE TITLE BLOCK THERE IS NO
 DESIGNERS NAME TAKING RESPONSIBILITY FOR THE DESIGN. IT
 WOULD APPEAR THAT INTERNATIONAL COLD STORAGE IS THE
 DESIGNER. 2014 FLORIDA BUILDING CODE W 2014 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION 107.3.4 DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE.
  
 3) SHEET K-3 IN THE CENTER OF THE SHEET THERE IS THE
 WIND DESIGN CRITERIA. UNDER THE HEADINGCOMPONENTS AND
 CLADDING ULTIMATE WIND.
 PRESSURES WALL ARE IN VULT. PLEASE CONVERT TO VASD
 SINCE ALL PRODUCT APPROVALS ARE IN VASD.
 ROOF PRESSURES DO NOT PROVIDE THE SQAURE FOOT AREA
 THESE PRESSURES WERE TAKEN FOR? FOR THE COMPONENTS AND
 CLADDING THE SQUARE FOOT AREA IS UASULLY TAKEN FOR THE
 FASTENERS OR 10 SQ. FT. IT ALSO APPEARS THEY ARE IN
 VULT, PLEASE ALSO PROVIDE IN VASD SINCE ALL PRODUCT
 APPROVALS ARE IN VASD. 1609.3.1 WIND SPEED CONVERSION.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-10-18 Cont ID  
Sent By jwitmer Date 2016-10-18 Time 07:29 Rev Time 0.00
Received By jwitmer Date 2016-10-18 Time 07:02 Sent To  
Notes
2016-10-18 07:22:44MASTER PERMIT: 15110510 SHOWS THERE IS A STRUCTURAL
 SURROUND, THIS WALKIN COOLER/ FREEZER IS AN INSIDE
 INSTALATION.
 MATER PERMIT 15110510 SHEETS ILLISTRATE AN INTERIOR
 INSTALATION:
 A-1.3
 A-1.5
 A-3.4
 A-5.2
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-01-19 Cont ID  
Sent By hmoser Date 2017-01-19 Time 06:30 Rev Time 0.00
Received By hmoser Date 2017-01-17 Time 11:05 Sent To  
Notes
2017-01-17 11:05:16RESUB ROUTED TO JWITMER'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-12-30 Cont ID  
Sent By jwitmer Date 2016-12-30 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2016-12-27 Time 17:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-02 Cont ID  
Sent By ccole Date 2016-11-02 Time 15:54 Rev Time 0.00
Received By ccole Date 2016-10-27 Time 11:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-18 Cont ID  
Sent By jwitmer Date 2016-10-18 Time 07:22 Rev Time 0.00
Received By jwitmer Date 2016-09-22 Time 13:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2017-01-19 Cont ID  
Sent By hmoser Date 2017-01-19 Time 06:29 Rev Time 0.00
Received By hmoser Date 2017-01-19 Time 06:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-12-29 Cont ID  
Sent By ccole Date 2016-12-29 Time 13:58 Rev Time 0.00
Received By ccole Date 2016-12-29 Time 13:58 Sent To  
Notes
2016-12-29 14:16:032ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16090626
 12/28/16
  
 1) SEPARATE PERMITS REQUIRE SEPARATE DRAWING
 SUBMITTALS. PLEASE SUBMIT ALL REQUIRED SHEETS FROM THE
 MAIN PERMITTED PLANS. THE MECHANICAL REVIEW OF THE
 WALK-IN COOLER WAS NOT DONE UNDER THE MAIN PERMIT.
  
 2) I WAS UNABLE TO LOCATE THE FLORIDA PRODUCT APPROVAL
 FOR THE INTERNATIONAL COLD STORAGE WALKIN
 COOLER-FREEZER ON THE ONLINE DIRECTORY. PLEASE PROVIDE
 A COPY OF THE DOCUMENT OR THE FL. PRODUCT APPROVAL
 CERTIFICATRION NUMBER.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-11-02 Cont ID  
Sent By ccole Date 2016-11-02 Time 15:32 Rev Time 0.00
Received By ccole Date 2016-11-02 Time 15:31 Sent To  
Notes
2016-11-02 15:33:442ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16090626
 11/2/16
  
 COMMENTS FROM THE 1ST REVIEW STILL EXIST. I AM
 REPRINTING THEM BELOW WITH SOME ADDITIONAL REVIEW
 NOTES.
  
 1) PLEASE PROVIDE THE FOLLOWING: A) REFRIGERATION
 EQUIPMENT SCHEDULES. B) LOCATIONS OF REFRIGERATION
 EQUIPMENT AND REFRIGERANT PIPING RUNS AND PIPE DETAILS.
 C) EVAPORATOR CONDENSATE DISPOSAL DETAILS. D) WIND LOAD
 ENGINEERING FOR INSTALLATION OF THE WALK-IN BOXES AND
 THE EXTERIOR CONDENSER.
  
 2) THE UPLOADED SUBMITTAL FROM PFS CORPORATION
 INDICATES THAT THE WALK-IN COOLER HAS BEEN APPROVED IN
 ACCORDANCE WITH SECTION 61G20-3 FAC FOR PRODUCT
 APPROVAL. PLEASE PROVIDE A COPY OF THE PRODUCT
 APPROVAL.
  
 3) THE UPLOADED K-3 PLAN SHEET REQUIRES AN ELECTRONIC
 SIGNATURE AND SEAL FROM THE ARCHITECT OF RECORD ANDREW
 N. SHARE- SEE SECTION 61G1-16.005 FAC
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-29 Cont ID  
Sent By ccole Date 2016-09-29 Time 12:13 Rev Time 0.00
Received By ccole Date 2016-09-29 Time 12:04 Sent To  
Notes
2016-09-29 12:24:361ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16090626
 9/29/16
  
 1) BECAUSE THE WALK-IN COOLER AND FREEZER ARE BEING
 PERMITTED SEPARATELY FROM THE MAIN RESTAURANT
 OCCUPANCY, COMPLETE PLANS AND DETAILS ARE REQUIRED-
 ONLY ONE PLAN SHEET WAS EXPORTED FROM THE MAIN SETS.
 PLEASE PROVIDE THE FOLLOWING: A) REFRIGERATION
 EQUIPMENT SCHEDULES. B) LOCATIONS OF REFRIGERATION
 EQUIPMENT AND REFRIGERANT PIPING RUNS AND PIPE DETAILS.
 C) EVAPORATOR
  
 CONDENSATE DISPOSAL DETAILS. D) WIND LOAD ENGINEERING
 FOR INSTALLATION OF THE WALK-IN BOXES AND THE EXTERIOR
 CONDENSER.
  
 2) PLEASE NOTE THAT THE EXTERIOR WALK-IN BOXES WILL
 REQUIRE A STRUCTURAL REVIEW.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  