Plan Review Details - Permit 16090494
| Plan Review Stops For Permit 16090494 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-09-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-22 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-22 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-22 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-21 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2016-09-21 11:11:06 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-17 |
Time |
04:52 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-14 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2016-09-15 11:09:40 | PLUMBING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-09-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-22 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-22 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-09-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-22 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-22 |
Time |
06:26 |
Sent To |
|
|
| Notes |
| 2016-09-22 06:33:08 | 1) THE RESUBMITTED PLANS ARE UNACCEPTABLE. THERE ARE | | | NOTES ON THE PLANS THAT ARE ILLEGIBLE, ITEMS ARE | | | CROSSED OUT, ETC. SUBMIT A CLEAN SET OF PLANS THAT | | | CLEARLY REFLECT THE SCOPE OF WORK AND ALL NOTES SHALL | | | BE CLEAR IN DETAIL.WPB AMEND. TO FBC SEC. 107.2.1. | | | I SUGGEST YOU CALL TO SET UP AN APPOINTMENT AND BRING | | | IN CLEAN PLANS THAT CAN BE MARKED UP SO YOUR PERMIT CAN | | | BE ISSUED. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-09-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-17 |
Time |
04:52 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-17 |
Time |
04:43 |
Sent To |
|
|
| Notes |
| 2016-09-17 04:52:09 | 1) A SEPARATE PERMIT IS REQUIRED FOR THE BACKFLOW | | | DEVICE AND A PLUMBING APPLICATION IS REQUIRED AS AN | | | IRRIGATION CONTRACTOR CANNOT INSTALL THE BACKFLOW | | | DEVICE ON A POTABLE WATER LINE. FL. STATUTES 489.103. | | | 2) SHOW THE LOCATION OF THE CONTROLLER, THE RAIN SENSOR | | | AND THE WATER METER AND BACKFLOW DEVICE ON THE PLAN. | | | 3) THE FOLLOWING INFORMATION IS REQUIRED FOR THE | | | BACKFLOW PERMIT. | | | 4) TWO COPIES OF THE MANUFACTURER?S SPECIFICATIONS FOR | | | THE BACKFLOW PREVENTER. THE MAKE, MODEL AND SIZE OF THE | | | DEVICE SHALL BE NOTED IN THE DESCRIPTION OF WORK | | | SECTION ON THE PERMIT APPLICATION. | | | 5) ALL BACKFLOW DEVICES MUST BE LEAD FREE. | | | 6) ALL BACKFLOW DEVICES MUST BE ON THE UNIVERSITY OF | | | SOUTHERN CALIFORNIA?S ( USC ) LIST OF APPROVED DEVICES. | | | 7) BACKFLOW PREVENTION DEVICES SHALL BE LOCATED | | | IMMEDIATELY AFTER THE METER AND MUST BE TESTED AND | | | CERTIFIED BY THE CITY OF WEST PALM BEACH UTILITIES | | | DEPARTMENT. PLEASE CONTACT THE CITY OF WEST PALM BEACH | | | PUBLIC UTILITIES CENTRAL OPERATIONS AT 561-822-2210 TO | | | ARRANGE FOR THE UTILITIES DEPARTMENT TO CERTIFY THE | | | DEVICE. | | | | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
|