Plan Review Details - Permit 16090395
Plan Review Stops For Permit 16090395
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-12-13 Cont ID  
Sent By cthroop Date 2016-12-13 Time 08:41 Rev Time 0.00
Received By cthroop Date 2016-12-13 Time 08:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-11-15 Cont ID  
Sent By cthroop Date 2016-11-15 Time 09:28 Rev Time 0.00
Received By cthroop Date 2016-11-15 Time 08:37 Sent To  
Notes
2016-11-15 09:30:48BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
  
 1. PROVIDE ENERGY SUBMITTAL. CANNOT VERIFY CEILING AND
 WALL INSULATION. (PLAN PAGE A2)

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-10-14 Cont ID  
Sent By cthroop Date 2016-10-14 Time 10:05 Rev Time 0.00
Received By cthroop Date 2016-10-14 Time 08:50 Sent To  
Notes
2016-10-14 10:24:50BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 1. PROVIDE ENERGY SUBMITTAL.
 2. ROOFING PERMIT REQUIRED.
 3. PALM BEACH COUNTY IMPACT FEES REQUIRED. CONDITIONED
 SPACE INCREASED BY 43.25 SQ. FT.
 4. PROVIDE DETAIL FOR NEW RIDGE BOARD TO EXISTING
 RAFTER CONNECTION ( SEE PG. A2).
 5. PROVIDE LANDINGS AT EXTERIOR DOORS PER R311.3
 6. PROVIDE DETAIL FOR NEW SLAB TO EXISTING FOUNDATION
 (SEE PG. A3).
 7. PROVIDE ELEVATIONS OF EXISTING FINISHED FLOOR AND
 NEW SLAB AT LAUNDRY ROOM.
 8. PROOF OF TERMITE TREATMENT REQUIRED FOR NEW
 CONDITIONED SPACE.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
 (MANDATORY).
 THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY
 PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND
 CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT
 BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY.
 FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)]
 REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN
 ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND
 NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD
 CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE
 LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A
 DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT
 THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE
 BUILDER ACCURATELY REFLECTS THE PLANS AND
 SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE
 FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE
 FOUND IN APPENDIX C.
  
 R311.3.1 FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS.
 LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR
 SHALL NOT BE MORE THAN 11/2 INCHES (38 MM) LOWER THAN
 THE TOP OF THE THRESHOLD.
  
 R403.1.7.3 FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS.
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE
 DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE
 PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT
 VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT).
  
 R311.3.1 FLOOR ELEVATIONS AT THE REQUIRED EGRESS DOORS.
 LANDINGS OR FINISHED FLOORS AT THE REQUIRED EGRESS DOOR
 SHALL NOT BE MORE THAN 11/2 INCHES (38 MM) LOWER THAN
 THE TOP OF THE THRESHOLD.
  
 FBC 107.3.5.3 ? INDICATE THE MEANS OF TERMITE
 PROTECTION PROPOSED PURSUANT TO FBC-R318.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-11-09 Cont ID  
Sent By vperez Date 2016-11-09 Time 12:05 Rev Time 0.00
Received By vperez Date 2016-11-09 Time 12:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-09-14 Cont ID  
Sent By albarran Date 2016-09-14 Time 14:50 Rev Time 0.00
Received By albarran Date 2016-09-14 Time 13:15 Sent To  
Notes
2016-09-14 14:50:471ST ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH: 5TH EDITION FBC 2014 &
 NFPA 70 2011 (NEC)
  
 PROJECT NAME:
 JOB ADDRESS: 1018 14TH STREET
 DESCRIPTION: TRUSS REPAIR AND INTERIOR RENOVATION
 MASTER PERMIT: 16090395
  
 BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS.
 ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF
 SUBMITTED CORRECTIONS.
  
 1. YOU SHALL SUBMIT A SITE PLAN SHOWING THE LOCATION OF
 THE ELECTRIC UTILITY POLE SERVING THE RESIDENCE ALONG
 WITH THE LOCATION OF THE ELECTRIC METER AND MAIN
 DISCONNECT. YOU SHALL MARK BOTH, THE EXISTING AND
 PROPOSED LOCATIONS. YOU SHALL INDICATE IF THE SERVICE
 FEEDER IS AERIAL OR UNDERGROUND.
 2. THE WORD ROMEX AS USED IN THIS NOTE IS TO IDENTIFY A
 TYPE OF CABLE. ROMEX IS A BRAND NAME AND NOT A TYPE OF
 CABLE, REFER TO CABLE TYPES NM, NMC OR NMS. CORRECT
 ELECTRICAL SERVICE NOTES #10.
 3. YOU SHALL COMPLETE THE A/C CHANGE-OUT FORM TO CROSS
 REFERENCE DETAILS FOR THE LOADS CALCS AND PANEL
 SCHEDULE. THIS WILL ALSO BE REQUIRED FOR THE MECHANICAL
 REVIEW.
 4. NOTE THAT IT IS THE AMBIENT CONDITIONS WHICH
 DETERMINE CONDUCTOR INSULATION TYPE AND NOT THE WIRE
 GAUGE. ALL CONDUCTORS EXPOSED TO DAMP OR WET LOCATIONS
 SHALL BE LISTED ACCORDINGLY REGARDLESS OF GAUGE.
 CORRECT ELECTRICAL SPECIFICATIONS NOTE #3 ACCORDINGLY.
 5. FBC-RE3602.2/NEC 220.82 SERVICE LOAD: CORRECT THE
 ELECTRICAL LOAD CALCS. YOUR FIGURES INDICATE 2660 SQ.
 FT. AND THE PROPERTY APPRAISER SHOWS ONLY 962 SQ. FT.
 FOR THE RESIDENCE. THE A/C CHANGE-OUT FORM INDICATES A
 5KW HEATER; THE LOAD CALCS SHOW 10KW. CHECK THE MATH
 6. THE FLOOR PLAN REFLECTS A RANGE W/AN OVEN AND ALSO A
 COOK TOP W/OVEN. THIS DIFFERS FROM THE CIRCUIT
 DIRECTORY AND LOAD CALCS. CORRECT ACCORDINGLY.
 7. FBC-R4002.9 NEC 406.9(B) RECEPTACLES IN WET
 LOCATIONS. 15 AND 20 AMPERE, 125 AND 250 VOLT
 RECEPTACLES INSTALLED IN A WET LOCATION SHALL HAVE AN
 ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE
 ATTACHMENT PLUG CAP IS INSERTED. ALL 15 AND 20 AMPERE,
 125 AND 250 VOLT NONLOCKING RECEPTACLES SHALL BE LISTED
 WEATHER-RESISTANT TYPE WR. THIS CAN BE ADDRESSED WITH A
 BLOCK NOTE ADDED TO THE EXISTING NOTES.
 8. FBC-RE3905.8 NEC 314.27(D) PADDLE FANS. BOXES USED
 FOR THE SOLE SUPPORT OF CEILING FANS SHALL BE MARKED BY
 THE MANUFACTURER AS SUITABLE FOR THE PURPOSE, AND
 INDICATE THE WEIGHT LIMITATIONS BUT SHALL NOT BE USED
 TO SUPPORT PADDLE FANS HEAVIER THAN 70 LBS. THIS TOO
 CAN BE ADDRESSED WITH A BLOCK NOTE.
 9. FBC-RE3903.3/NEC 210.70(A)(2)(B): AT LEAST ONE
 WALL-SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE
 INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR SIDE
 OF EACH OUTDOOR EGRESS DOOR HAVING GRADE LEVEL ACCESS.
 THIS APPLIES TO THE DOOR LEADING OUTSIDE FROM THE
 LAUNDRY AREA.
 10. FBC-RE3901.2.2 NEC 210.52 (A)(2) WALL SPACE. ANY
 WALL SPACE 2 FT. OR MORE IN WIDTH SHALL REQUIRE A
 RECEPTACLE. OUTLETS MISSING IN THE BEDROOMS ON THE WALL
 BETWEEN THE ENTRY DOOR AND THE CLOSET.
 11. FBC-R404.1 LIGHTING EQUIPMENT (MANDATORY). A
 MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY
 LAMPS OR A MINIMUM OF 75 PERCENT OF THE PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH
 EFFICACY LAMPS.
  
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2016-12-15 Cont ID  
Sent By cpuell Date 2016-12-15 Time 12:32 Rev Time 0.00
Received By cpuell Date 2016-12-14 Time 11:45 Sent To  
Notes
2016-12-14 11:45:28RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-12-13 Cont ID  
Sent By cthroop Date 2016-12-13 Time 08:41 Rev Time 0.00
Received By cthroop Date 2016-12-09 Time 13:31 Sent To  
Notes
2016-12-12 18:28:39ROUTED TO CHRIS THROOP 12/12/2016 - JORGE V.
2016-12-12 13:32:12RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-12-02 Cont ID  
Sent By cthroop Date 2016-12-02 Time 08:46 Rev Time 0.00
Received By cthroop Date 2016-11-30 Time 10:58 Sent To  
Notes
2016-12-01 10:58:45IMPACT FEES ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-18 Cont ID  
Sent By cpuell Date 2016-11-18 Time 09:32 Rev Time 0.00
Received By cpuell Date 2016-11-03 Time 15:08 Sent To  
Notes
2016-11-03 15:08:37R19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-14 Cont ID  
Sent By skennedy Date 2016-10-14 Time 12:04 Rev Time 0.00
Received By skennedy Date 2016-09-13 Time 14:29 Sent To  
Notes
2016-09-13 14:29:52R13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-12-02 Cont ID  
Sent By cthroop Date 2016-12-02 Time 08:47 Rev Time 0.00
Received By cthroop Date 2016-12-02 Time 08:47 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-10-14 Cont ID  
Sent By cthroop Date 2016-10-14 Time 10:03 Rev Time 0.00
Received By cthroop Date 2016-10-14 Time 10:03 Sent To  
Notes
2016-10-14 10:04:54BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 1. CONDITIONED SPACE INCREASED BY 43.25 SQ. FT.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2016-12-14 Cont ID  
Sent By jvalido Date 2016-12-14 Time 16:59 Rev Time 0.00
Received By jvalido Date 2016-12-14 Time 16:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-12-12 Cont ID  
Sent By jvalido Date 2016-12-12 Time 18:26 Rev Time 0.00
Received By jvalido Date 2016-12-12 Time 16:19 Sent To  
Notes
2016-12-12 18:26:41CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE AN EQUIPMENT SCHEDULE ON THE SUBMITTED
 PLANS.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (2) FORM R405-2014 REQUIRES A SIGNATURE ON OWNER/
 AGENT. (SEE HIGHLIGHTED AREA)
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-11-17 Cont ID  
Sent By jvalido Date 2016-11-17 Time 17:18 Rev Time 0.00
Received By jvalido Date 2016-11-17 Time 16:58 Sent To  
Notes
2016-11-17 17:09:28CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS
 FOR PLANS AND SPECIFICATIONS, IN
 ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION
 PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF
 FLORIDA STATUTES.
  
 (1) PROVIDE MECHANICAL PLANS AS REQUESTED ON PRIOR
 MECHANICAL REVIEW ( SEE 107.2.1.4)
 (2) PROVIDE EQUIPMENT SCHEDULE ON PLANS.
  
 FLORIDA ENERGY CODE FBC 2014
 R403.6.1 EQUIPMENT SIZING
  
 (3) PROVIDE ENERGY CALCULATIONS AS INSTRUCTED ON PRIOR
 MECHANICAL REVIEW. (R405-2014)
 (4) PROVIDE HEAT LOAD CALCULATIONS AS REQUESTED ON
 PRIOR MECHANICAL REVIEW.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-14 Cont ID  
Sent By skennedy Date 2016-10-14 Time 11:58 Rev Time 0.00
Received By skennedy Date 2016-10-14 Time 11:58 Sent To  
Notes
2016-10-14 12:04:361ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 PROVIDE AN ENERGY SUBMITTAL AS FOLLOWS AS THE WORK
 CONSTITUTES A RENOVATION:
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 PROVIED AN EQUIPMENT SIZING CALCULATION AS FOLLOWS:
  
 R403.6.1 EQUIPMENT SIZING.
 HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN
 ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT
 LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES, BASED ON BUILDING LOADS FOR THE
 DIRECTIONAL ORIENTATION OF THE BUILDING. THE
 MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR
 UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH
 THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN
 CONDITIONS DESCRIBED IN SECTION R302.1. THIS CODE DOES
 NOT ALLOW DESIGNER SAFETY FACTORS, PROVISIONS FOR
 FUTURE EXPANSION OR OTHER FACTORS WHICH AFFECT
 EQUIPMENT SIZING. SYSTEM SIZING CALCULATIONS SHALL NOT
 INCLUDE LOADS CREATED BY LOCAL INTERMITTENT MECHANICAL
 VENTILATION SUCH AS STANDARD KITCHEN AND BATHROOM
 EXHAUST SYSTEMS.
  
 R403.6.1.1 COOLING EQUIPMENT CAPACITY.
 COOLING ONLY EQUIPMENT SHALL BE SELECTED SO THAT ITS
 TOTAL CAPACITY IS NOT LESS THAN THE CALCULATED TOTAL
 LOAD, BUT NOT MORE THAN 1.15 TIMES GREATER THAN THE
 TOTAL LOAD CALCULATED ACCORDING TO THE PROCEDURE
 SELECTED IN SECTION 403.6, OR THE CLOSEST AVAILABLE
 SIZE PROVIDED BY THE MANUFACTURER?S PRODUCT LINES. THE
 CORRESPONDING LATENT CAPACITY OF THE EQUIPMENT SHALL
 NOT BE LESS THAN THE CALCULATED LATENT LOAD.
  
  
 FBC 107, PROVIDE A DUCT PLAN FOR ANY PROPOSED NEW DUCT
 WORK OR STIPULATE OTHERWISE.
  
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-11-17 Cont ID  
Sent By gjohnson Date 2016-11-17 Time 16:24 Rev Time 0.00
Received By gjohnson Date 2016-11-17 Time 16:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-10-12 Cont ID  
Sent By gjohnson Date 2016-10-12 Time 15:11 Rev Time 0.00
Received By gjohnson Date 2016-10-12 Time 15:11 Sent To  
Notes
2016-10-12 15:16:381ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. KITCHEN SINK SHALL CONNECT TO BUILDING DRAIN
 DOWNSTREAM OF BATHROOM GROUP. PER FBC RES P3108.1
 HORIZONTAL WET VENT PERMITTED.
 ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS
 LOCATED ON THE SAME FLOOR LEVEL SHALL BE PERMITTED TO
 BE VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL
 BE CONSIDERED THE VENT FOR THE FIXTURES AND SHALL
 EXTEND FROM THE CONNECTION OF THE DRY VENT ALONG THE
 DIRECTION OF THE FLOW IN THE DRAIN PIPE TO THE MOST
 DOWNSTREAM FIXTURE DRAIN CONNECTION. EACH FIXTURE DRAIN
 SHALL CONNECT HORIZONTALLY TO THE HORIZONTAL BRANCH
 BEING WET VENTED OR SHALL HAVE A DRY VENT. EACH
 WET-VENTED FIXTURE DRAIN SHALL CONNECT INDEPENDENTLY TO
 THE HORIZONTAL WET VENT. ONLY THE FIXTURES WITHIN THE
 BATHROOM GROUPS SHALL CONNECT TO THE WET-VENTED
 HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL FIXTURES SHALL
 DISCHARGE DOWNSTREAM OF THE HORIZONTAL WET VENT.
  
 2. PROVIDE MANUFACTURE SPECIFICATIONS FOR TANLESS WATER
 HEATER. PER WPB AMEND. TO FBC 107.2

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-10-14 Cont ID  
Sent By cthroop Date 2016-10-14 Time 08:58 Rev Time 0.00
Received By cthroop Date 2016-10-14 Time 08:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-11-15 Cont ID  
Sent By awooten Date 2016-11-15 Time   Rev Time 0.00
Received By awooten Date 2016-11-15 Time   Sent To  
Notes
2016-11-15 11:49:09******ZONING FAILED*******
  
 THIS IS NOT JUST AN INTERIOR REMODEL, THE FOOTPRINT OF
 THE BUILDING IS CHANGING (CONDITIONED SPACE IS
 INCREASING). PLEASE PROVIDE A SURVEY OR SITE PLAN OF
 BUILDING SHOWING EXISTING AND NEW SETBACKS IN RELATION
 TO ADDITION.
  
 PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY HAVE.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2016-09-20 Cont ID  
Sent By awooten Date 2016-09-20 Time 14:34 Rev Time 0.00
Received By awooten Date 2016-09-16 Time 15:01 Sent To  
Notes
***NONE***