Plan Review Details - Permit 16090393
| Plan Review Stops For Permit 16090393 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-10-24 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-10-24 |
Time |
18:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-20 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-20 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2016-09-20 09:35:56 | RESIDENTIAL (R3) SCREEN ENCLOSURE, BUILDING REVIEW | | | COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- PLANS SUBMITTED SEEM TO HAVE AN ENGINEER'S RUBBER | | | STAMP OR COPY OF A SIGNATURE. ENGINEER NEEDS TO PROVIDE | | | PLANS (2 COPIES) WITH ORIGINAL SIGNATURE AS REQUIRED BY | | | CHAPTER 471 FLORIDA STATUTES WHEN SUBMITTING PLANS FOR | | | PUBLIC RECORD. | | | | | | 2- SHEET 1 OF 4 OF DRAWINGS SUBMITTED: THERE IS A NOTE | | | STATING "NEW SCREEN ENCLOSURE ON NEW PAVER DECK W/ | | | 18"X12" CONCRETE FOOTER". PROVIDE COMPLETE | | | SECTION/DETAIL AND SPECIFICATIONS FOR THE FOOTING TO | | | RECEIVE THE PROPOSED SCREEN ENCLOSURE. AND, ENGINEER TO | | | CLARIFY IN WRITING WHY THERE IS NO REINFORCEMENT FOR | | | THE CONCRETE FOOTING. SEC. R301.1 FBC-RESIDENTIAL, 5TH | | | EDITION (2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-10-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-10-24 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-10-20 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2016-10-20 16:44:51 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-20 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-13 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2016-09-13 13:20:01 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-09-16 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-09-16 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-09-13 |
Time |
14:23 |
Sent To |
B |
|
| Notes |
| 2016-09-16 17:20:50 | 9/16/16- PASSED | | | | | | IBIS PLANNED DEVELOPMENT | | | | | | 1. REAR SETBACK IS 7.82FT AND MEETS THE 3FT. SETBACK | | | REQUIREMENT. | | | 2. SIDE SETBACK IS 7FT. AND MEETS THE 3FT. MINIMUM | | | SETBACK | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|
|