Plan Review Details - Permit 16090373
| Plan Review Stops For Permit 16090373 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-14 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-14 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-10-13 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-10-13 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2016-10-13 13:05:17 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ENGINEERING REFERS TO A MIAMI DADE NOA, PRODUCT | | | APPROVAL SUBMITTED IS A FLORIDA STATE PRODUCT APPROVAL. | | | ENGINEERING IS TO BE CONSISTENT WITH THE PRODUCT | | | APPROVAL. | | | | | | 2. FBC 5TH EDITION RESIDENTIAL 301, THE ENGINEERING | | | DOES NOT REFER TO THE APPROVED ASSEMBLY SELECTED. | | | REVISE ENGINEERING TO INCLUDE EITHER THE ASSEMBLY | | | NUMBER OR PAGE NUMBER. | | | | | | 3. ENGINEERING IS TO INCLUDE A COMPLETE TITLE BLOCK IN | | | COMPLIANCE WITH FS471 AND FAC61G15-23.002. THE | | | ENGINEER'S PRINTED NAME, LICENSE NUMBER, CERTIFICATE OF | | | AUTHORIZATION ARE LACKING. THE SEAL IS REQUIRED TO | | | INCLUDE A DATE. | | | | | | 4. CONTRACTOR'S ROOF DRAWING STATES THAT ZONE 2 AND 3 | | | WILL BE 3'. FOUR FEET IS REQUIRED AS A MINIMUM, SEE FBC | | | 5TH EDITION RESIDENTIAL R301.2(7) FOOTNOTE REGARDING | | | DIMENSION A. REVISE ROOF PLAN. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-09-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-09-12 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-09-12 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2016-09-12 15:42:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SEE LIMITATION 5.8, A QUALIFIED DESIGN PROFESSIONAL | | | IS REQUIRED FOR RAS 117 CALCULATIONS (FLAT DECK). | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-14 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-09 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2016-12-12 11:25:31 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-10-13 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-10-11 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2016-10-11 15:29:31 | RESUB ROUTED TO SHILL |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |