| Plan Review Stops For Permit 16090358 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-09-22 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-22 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-22 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-15 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-15 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2016-09-15 14:08:10 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1] PROVIDE A PANEL SCHEDULE, SHOW CONDUIT AND WIRE | | | SIZES ON THE RISER DIAGRAM, AND CLARIFY HOW LOAD | | | CALCULATION VALUE FOR THE DRYER IS 1500 VA ? PLEASE | | | ADJUST ACCORDINGLY. FBC 107.3.5.3 | | | | | | 2] THE INTER-SYSTEM BONDING TERMINAL SHALL BE INSTALLED | | | AS PER FBC-R_E3609.3 | | | | | | 3] CARBON MONOXIODE ALARMS REQUIRED WITHIN 10' OF EACH | | | SLEEPING ROOM. FBC-R 315.1 ( ATTACHED GARAGE ) | | | | | | 4] MAIN DOOR BY THE FOYER REQUIRES A SWITCHED LIGHTING | | | OUTLET ON THE EXTERIOR SIDE OF THE OUTDOOR EGRESS. | | | FBC-R _E3903.3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-15 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-12 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2016-09-12 14:59:19 | ROUTED TO ELECTRICAL INBOX |
|
|
|