Plan Review Details - Permit 16090271
Plan Review Stops For Permit 16090271
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-11-01 Cont ID  
Sent By cthroop Date 2016-11-01 Time 14:54 Rev Time 0.00
Received By cthroop Date 2016-11-01 Time 14:36 Sent To  
Notes
2016-10-22 09:16:07 
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-09-28 Cont ID  
Sent By cthroop Date 2016-09-19 Time 13:13 Rev Time 0.00
Received By cthroop Date 2016-09-19 Time 10:36 Sent To  
Notes
2016-09-19 13:15:51NO NOTES

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-10-24 Cont ID  
Sent By mvaldes Date 2016-10-24 Time 13:36 Rev Time 0.00
Received By mvaldes Date 2016-10-24 Time 12:44 Sent To  
Notes
2016-10-24 13:35:53REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO'S (RED-LINED ON
 PLANS)
  
 1] PERMANENT LIGHTING SHALL BE 75% HIGH EFFICIENCY AND
 RECESSED FIXTURES SHALL BE LISTED IC-RATED SEALED TO
 NOT COMPROMISE BUILDING THERMAL ENVELOPE. FBC-E
 SECTIONS R402.4.4 & R404.1 ADD TO ELECTRICAL NOTES.
  
 2] ALL 1ST FLOOR SWITCHES CONTROLLING LIGHTING LOADS
 SHALL HAVE A GROUNDED (NEUTRAL) CONDUCTOR AT THE SWITCH
 LOCATION. FUTURE INSTALLATION WOULDN'T BE ACCESSIBLE
 WITH THE ADDITION OF THE 2ND FLOOR. FBC-R SECTION
 E4001.15
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-09-12 Cont ID  
Sent By mvaldes Date 2016-09-12 Time 15:42 Rev Time 0.00
Received By mvaldes Date 2016-09-12 Time 14:07 Sent To M
Notes
2016-09-12 16:23:46JOB PERMIT NUMBER: 16090271
 JOB ADDRESS: 224 BELMONTE ROAD
 WEST PALM BEACH FLORIDA 33405
 DATE: SEPTEMBER 12, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 1] PROVIDE EXISTING ELECTRIC SERVICE RISER WITH WIRE
 SIZES AND SPECIFY IF ADEQUATE TO HANDLE ADDED LOADS,
 CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE NEW
 REVISED LOAD CALCULATIONS, PANEL SCHEDULES AND IDENTIFY
 NEW CIRCUITS ON FLOOR PLAN. FBC- 107.3.5.3
  
 2] PERMANENT LIGHTING SHALL BE 75% HIGH EFFICIENCY AND
 RECESSED FIXTURES SHALL BE LISTED IC-RATED SEALED TO
 NOT COMPROMISE BUILDING THERMAL ENVELOPE. FBC-E
 SECTIONS R402.4.4 & R404.1 ADD TO ELECTRICAL NOTES.
  
 3] ALL 1ST FLOOR SWITCHES CONTROLLING LIGHTING LOADS
 SHALL HAVE A GROUNDED (NEUTRAL) CONDUCTOR AT THE SWITCH
 LOCATION. FUTURE INSTALLATION WOULDN'T BE ACCESSIBLE
 WITH THE ADDITION OF THE 2ND FLOOR. FBC-R SECTION
 E4001.15
  
 4] KITCHEN-ISLAND SHALL HAVE A GFCI RECEPTACLE OUTLET
 AT BOTH ENDS WITHIN 12'' OF THE COUNTERTOP. FBC-R
 SECTION E3901.4.2
  
 5] ACCU # 1, ACCU # 2, AND POOL PUMP REFLECT
 DISCONNECTS BEHIND THE EQUIPMENT PLEASE RELOCATE TO
 COMPLY WITH WORKING CLEARANCES. FBC-R SECTION E3405.1
  
 6] MISSING CARBON MONOXIDE ALARM BY THE UP-STAIRS
 LANDING AND A SMOKE ALARM IN THE MASTER BEDROOM PER
 FBC-R 314 & 315.
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.WHEN RESUBMITTING, FOR A QUICKER
 RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. IF
 YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 5 Status P Date 2016-12-02 Cont ID  
Sent By tklarge Date 2016-12-02 Time 13:33 Rev Time 0.00
Received By tklarge Date 2016-12-02 Time 13:33 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 4 Status F Date 2016-11-22 Cont ID  
Sent By tklarge Date 2016-11-22 Time 07:51 Rev Time 0.00
Received By tklarge Date 2016-11-22 Time 05:32 Sent To  
Notes
2016-11-22 07:35:511) WHAT ARE THE DIMENSIONS OF THE LOUVERS IN THE
 GARAGE? YOU HAVE SUPPLIED THE TOTAL SQUARE INCH AREA
 BUT NOT THE LENGTH & WIDTH. ISN'T THE TANKLESS WATER
 HEATER A DIRECT VENT APPLIANCE? IF SO, WHY ARE
 COMBUSTION AIR OPENINGS BEING PROVIDED? CLARIFY.
 2) THE LOUVER OPENINGS FOR THE DRYER ARE
 UNDERSIZED.COMPLY WITH SEC. 2014 FBCR SEC.G2407.5.3.1,
 EACH OPENING SHALL HAVE A MINIMUM OF 100 SQUARE INCHES
 OF FREE AREA. METAL LOUVERS AND GRILLS SHALL BE ASSUMED
 TO HAVE A 75 PERCENT FREE AREA. 2014 FBBCR
 SEC.G2407.10. THEREFORE, THE TOTAL SQUARE INCH AREA OF
 THE LOUVERS SHALL BE MULTIPLIED BY 75 PERCENT TO OBTAIN
 THE FREE AREA.THE SIZE GRILL YOU HAVE SPECIFIED WILL
 NOT WORK.
 3) THE RINNAI SPECIFICATION SHEET STATES THAT THE
 MAXIMUM BTU LOAD IS 180,000 BUT THE GAS PLAN SHOWS
 225,00 BTU'S. CLARIFY.
 4) THE COPY OF THE CODE THAT WAS SUBMITTED FOR THE
 COMBUSTION AIR OPENINGS IS FROM THE 2007 FBC
 MECHANICAL. THE CODE IN EFFECT IS THE 2014 FBC NOT THE
 2007. I REFERENCED THE APPLICABLE CODE AND SECTION FOR
 COMBUSTION AIR IN MY PREVIOUS GAS REVIEW. I SUGGEST
 REFERRING TO IT.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2016-11-08 Cont ID  
Sent By tklarge Date 2016-11-08 Time 06:23 Rev Time 0.00
Received By tklarge Date 2016-11-08 Time 04:25 Sent To  
Notes
2016-11-08 06:21:001) THE ENERGY CALCULATIONS NOTE THE GAS FOR THE
 TANKLESS WATER HEATER AS PROPANE AND THE GAS DRAWING
 NOTES NATURAL GAS. CLARIFY. THIS IS THE THIRD TIME THIS
 COMMENT HAS BEEN NOTED AND THE THIRD TIME IT HAS NOT
 BEEN CORRECTED. IT IS NOT GOING AWAY. PLEASE SUBMIT TWO
 REVISED SETS OF ENERGY CALCULATIONS THAT SHOW THE GAS
 TO THE TANKLESS WATER HEATER AS NATURAL. THERE ARE
 SEVERAL PAGES IN THE ENERGY CALCULATIONS WHERE THIS
 OCCURS. CORRECT ALL APPLICABLE PAGES. WPB AMEND. TO FBC
 SEC. 107.2.1.
 2) WHAT TABLE IS BEING USED TO SIZE THE SCHEDULE 40
 METALLIC PIPE FOR THE 2 PSI SYSTEM? THE ONLY TABLE THAT
 WAS SUBMITTED FOR SCHEDULE 40 METALLIC PIPE IS FOR LESS
 THAN A 2 PSI SYSTEM.SUBMIT TWO COPIES OF THE APPLICABLE
 SIZING TABLE.WPB AMEND. TO FBC SEC. 107.2.1.
 3) THE GAS RISER SHOWS THE TANKLESS WATER HEATER SIX
 FEET AWAY FROM THE METER BUT THE FLOOR PLAN SHOWS THE
 TANKLESS WATER HEATER APPROXIMATELY 22 FEET FROM THE
 GAS METER. CLARIFY.
 4) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE DRYER AND
 COOKTOP. 2014 FBCR SEC.G2407. 3RD REQUEST.
 5) SUBMIT MANUFACTURER'S SPECIFFICATIONS FOR THE
 REGULATORS. SHOW HOW THESE REGULATORS WILL BE
 VENTED.2014 FBCR SEC. G2421.3.
 6) INSTALLATION MANUALS FOR ALL APPLIANCES SHALL BE
 ONSITE FOR GAS INSPECTION PER 2014 FBCR SEC.G2408.1.
 7) THE DOCUMENTS & PLANS FOR THE GAS SHALL BE ORGANIZED
 INTO TWO COMPLETE SETS OF PLANS AND DOCUMENTS. REMOVE
 ALL VOIDED PLANS/DOCUMENTS FOR THE GAS AND PLUMBING
 SYSTEM.WPB AMEND. TO FBC SEC. 107.2.1.
  
 **NOTE: SINCE THE GAS PLANS HAVE BEEN REJECTED THREE
 TIMES FOR THE SAME DEFICIENCIES, A RESUBMITTAL FEEE OF
 4 TIMES THE PLAN REVIEW FEE CAN BE ASSESSED AT THE NEXT
 RESUBMITTAL PERR FL. STATUTE 553.80 (2)(B).
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2016-10-22 Cont ID  
Sent By tklarge Date 2016-10-22 Time 09:20 Rev Time 0.00
Received By tklarge Date 2016-10-22 Time 08:55 Sent To  
Notes
2016-10-25 09:58:041) THE ENERGY CALCULATIONS NOTE THE GAS FOR THE WATER
 HEATER AS PROPANE AND THE GAS DRAWING NOTES NATURAL
 GAS. CLARIFY.
 2) THE SUBMITTED GAS SIZING TABLES ARE FROM AN OUTDATED
 CODE. SUBMIT COPIES OF THE APPROPRIATE SIZING TABLES
 FROM THE 2014 FBC-FUEL GAS CODE.
 3) THE BTU LOAD OF THE FUTURE BBQ AND THE POOL HEATER
 SHALL BE INCLUDED IN THE TOTAL BTU FOR THE SIZING LOAD
 OF THE SYSTEM. THE PLANS SHOW A GAS DRYER ON THE 2ND
 FLOOR. THIS SHALL ALSO BE ADDED INTO THE TOTAL BTU
 LOAD. SIZE THE SYSTEM FOR THE TOAL BTU LOAD.
 4) THE GAS DRYER SHALL BE INCLUDED ON THE GAS RISER
 DIAGRAM. WPB AMEND. TO FBC SEC. 107.3.5.3.
 5) SUBMIT A COMPLETE GAS RISER DIAGRAM SHOWING ALL THE
 TYPES OF PIPE BEING INSTALLED AND THAT CLEARLY SHOWS
 THE LENGTH OF ALL CUT SECTIONS OF PIPE PER 2014
 FBC-FUEL GAS, SECS. 402.4.1, 402.4.2. OR 2014 FBC-RES
 SEC. G2413.
 6) SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (GAS
 METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND / OR SYSTEM PER THE 2014
 FBC-FUEL GAS SEC.402.4.1 OR 2014 FBC-RES. SEC. G
 2413.3. THE GAS DRYER ON THE 2ND FLOOR MAY CHANGE THIS
 DISTANCE.
 7) SHOW THE LOCATION OF THE GAS METER, AND THE
 APPROXIMATE LOCATION OF THE FUTURE POOL HEATER AND BBQ
 ON THE FLOOR PLAN. WPB AMEND. TO FBC SEC. 107.2.1.
 8) SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR THE
 COOKTOP AND THE DRYER PER THE 2014 FBC-FUEL GAS CODE
 SEC.304.1 OR 2014 FBC-RES. SEC. G 2407.
 9) SHOW ALL PIPE SIZES, AND THE CORRESPONDING EHD
 NUMBER OF THE CORRUGATED STAINLESS STEEL TUBING FOR
 EACH PIPE SIZE. WPB AMENDMENTS TO FBC SEC.107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2016-10-11 Cont ID  
Sent By gjohnson Date 2016-10-11 Time 10:31 Rev Time 0.00
Received By gjohnson Date 2016-10-11 Time 10:31 Sent To  
Notes
2016-10-11 10:31:491ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 GAS COMMENTS:
  
 1. THE PLUMBING AND GAS DRAWINGS SHALL BE SIGNED BY THE
 PERSON RESPONSIBLE FOR THE DESIGN. IF BY CONTRACTOR THE
 LIC. NUMBER IS REQUIRED. PER WPB AMEND. TO BC 107.2.1
  
 2. PLEASE PROVIDE A PLAN SHOWING THE LOCATION OF GAS
 METER AND ALL APPLIANCES. PER WPB AMEND. TO BC 107.2.1
  
 3.ENERGY PERFORMANCE INDICATES A PROPANE GAS HEATER THE
 RISER INDICATES NATURAL GAS PLEASE CLARIFY. PER WPB
 AMEND. TO BC 107.2.1
  
 4. THE ELECTRIC SHEET SHOWS WATER HEATER INSIDE GARAGE,
 PE PIPE IS NOT ALLOWED TO BE RUN UNDER THE BUILDING.
 PER FBC RES
 G2415.17.1 (404.17.1)
  
 5. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL
 CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER
 FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2.
  
 6. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE
 SEC. 402.4.1.
  
 7. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2014 FUEL GAS CODE SEC. 304.
  
 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND
 TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE
 SEC. 502 THRU 505.
  
 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2
  
 10.BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON
 THE SYSTEM. BBQ NOT SHOWN REFER TO THE FBC-2014 FUEL
 GAS SECS. 401.8 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(37).
  
 11. INDICATE WHAT TABLE YOUR USING FOR SIZING. PER WPB
 AMEND TO FBC 107.2.1
  
  
  
  
  
  
  
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-10-05 Cont ID  
Sent By destabro Date 2016-10-04 Time 13:05 Rev Time 0.00
Received By destabro Date 2016-10-05 Time 11:47 Sent To B
Notes
2016-10-05 11:47:3010/5/2016 - CASEMENT WINDOW PRODUCT APPROVALS PROVIDED
 PER REQUEST - MEETS HPB REQUIREMENTS. DLE
2016-10-04 13:09:1410/4/2016 - CONTRIBUTING PROPERTY TO THE EL CID
 HISTORIC DISTRICT. PROPOSED WORK DOES NOT MATCH HPB
 APPROVAL (CASE NO. 16-59). HPB APPROVED ALUMINUM FRAME
 CASEMENT WINDOW REPLACEMENTS - PRODUCTS APPROVALS
 INCLUDED WITH THE PERMIT ARE FOR SINGLE-HUNG AND FIXED
 ONLY. PLEASE REVISE. DLE

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2016-11-23 Cont ID  
Sent By cpuell Date 2016-11-23 Time 11:34 Rev Time 0.00
Received By cpuell Date 2016-11-18 Time 15:33 Sent To  
Notes
2016-11-18 15:34:05RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-11-08 Cont ID  
Sent By tklarge Date 2016-11-08 Time 06:23 Rev Time 0.00
Received By tklarge Date 2016-11-03 Time 16:33 Sent To  
Notes
2016-11-07 14:09:57ROUTED TO TIM LARGE 11/7/2016 - JORGE V.
2016-11-03 16:33:32RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-11-01 Cont ID  
Sent By cthroop Date 2016-11-01 Time 14:36 Rev Time 0.00
Received By cthroop Date 2016-10-18 Time 11:39 Sent To  
Notes
2016-10-31 18:13:24ROUTED TO CHRIS THROOP 10/31/2016 - JORGE V.
2016-10-19 11:39:14R09

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-10-18 Cont ID  
Sent By cthroop Date 2016-10-18 Time 09:22 Rev Time 0.00
Received By cthroop Date 2016-10-17 Time 16:13 Sent To  
Notes
2016-10-17 16:13:29CTHROOP'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-12 Cont ID  
Sent By lmarchan Date 2016-10-12 Time 13:49 Rev Time 0.00
Received By lmarchan Date 2016-09-09 Time 15:33 Sent To  
Notes
2016-09-09 15:33:31R21

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-10-18 Cont ID  
Sent By cthroop Date 2016-10-18 Time 09:23 Rev Time 0.00
Received By cthroop Date 2016-10-18 Time 09:22 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-09-19 Cont ID  
Sent By cthroop Date 2016-09-19 Time 11:08 Rev Time 0.00
Received By cthroop Date 2016-09-19 Time 11:08 Sent To  
Notes
2016-09-19 11:09:53BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2016-11-22 Cont ID  
Sent By jvalido Date 2016-11-22 Time 17:54 Rev Time 0.00
Received By jvalido Date 2016-11-22 Time 16:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-11-07 Cont ID  
Sent By jvalido Date 2016-11-07 Time 14:06 Rev Time 0.00
Received By jvalido Date 2016-11-07 Time 12:58 Sent To  
Notes
2016-11-07 14:00:35CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 R403.6.1 - HEATING AND COOLING EQUIPMENT SHALL BE SIZED
 IN ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT
 LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES, BASED ON BUILDING LOADS FOR THE
 DIRECTIONAL ORIENTATION OF THE BUILDING. THE
 MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR
 UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH
 THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN
 CONDITIONS DESCRIBED IN
 SECTION R302.1. THIS CODE DOES NOT ALLOW DESIGNER
 SAFETY FACTORS, PROVISIONS FOR FUTURE EXPANSION OR
 OTHER FACTORS WHICH AFFECT EQUIPMENT SIZING. SYSTEM
 SIZING CALCULATIONS SHALL NOT INCLUDE LOADS CREATED BY
 LOCAL INTERMITTENT MECHANICAL VENTILATION SUCH AS
 STANDARD KITCHEN AND BATHROOM EXHAUST SYSTEMS.
  
 (1) PROVIDE EQUIPMENT SCHEDULE AS PER R403.6.1 FBC
 MECHANICAL 2014. (SEE ABOVE)
  
 FLORIDA ENERGY CODE FBC 2014
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-10-31 Cont ID  
Sent By jvalido Date 2016-10-31 Time 17:25 Rev Time 0.00
Received By jvalido Date 2016-10-31 Time 16:32 Sent To  
Notes
2016-10-31 16:47:09CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 M1503.4 MAKEUP AIR REQUIRED.
 EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF
 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE PROVIDED
 WITH MAKEUP AIR AT A RATE APPROXIMATELY EQUAL TO THE
 EXHAUST AIR RATE. SUCH MAKEUP AIR SYSTEMS SHALL BE
 EQUIPPED WITH A MEANS OF CLOSURE AND SHALL BE
 AUTOMATICALLY CONTROLLED TO START AND OPERATE
 SIMULTANEOUSLY WITH THE EXHAUST SYSTEM.
  
 R403.6.1 - HEATING AND COOLING EQUIPMENT SHALL BE SIZED
 IN ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT
 LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR
 OTHER APPROVED HEATING AND COOLING CALCULATION
 METHODOLOGIES, BASED ON BUILDING LOADS FOR THE
 DIRECTIONAL ORIENTATION OF THE BUILDING. THE
 MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR
 UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH
 THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN
 CONDITIONS DESCRIBED IN
 SECTION R302.1. THIS CODE DOES NOT ALLOW DESIGNER
 SAFETY FACTORS, PROVISIONS FOR FUTURE EXPANSION OR
 OTHER FACTORS WHICH AFFECT EQUIPMENT SIZING. SYSTEM
 SIZING CALCULATIONS SHALL NOT INCLUDE LOADS CREATED BY
 LOCAL INTERMITTENT MECHANICAL VENTILATION SUCH AS
 STANDARD KITCHEN AND BATHROOM EXHAUST SYSTEMS.
  
 (1) PROVIDE MAKE UP AIR FOR KITCHEN EXHAUST (AS PER
 M1503.4). (SEE ABOVE)
 (2) PROVIDE EQUIPMENT SCHEDULE AS PER R403.6.1 FBC
 MECHANICAL 2014. (SEE ABOVE)
  
 FLORIDA ENERGY CODE FBC 2014
  
 (3) FORMS R405-2014 MUST BE SIGNED BY "OWNER/AGENT"
 (SEE HIGHLIGHTED AREA ON FORMS)
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-11 Cont ID  
Sent By jvalido Date 2016-10-11 Time 18:51 Rev Time 0.00
Received By jvalido Date 2016-10-11 Time 18:10 Sent To  
Notes
2016-10-11 18:47:33CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE EQUIPMENT SCHEDULE AS PER R403.6.1 FBC
 MECHANICAL 2014
 (2) PROVIDE CFM VALUES FOR AL SUPPLY OUTLETS.
 (3) PROVIDE RETURN AIR FROM ALL BEDROOMS. (2ND FLOOR
 PROPOSED BEDROOM IS MISSING RETURN).
 (4) PROVIDE EXHAUST DUCT DETAIL IN ALL BATHROOMS. SHOW
 ALL DUCT SIZES AND EXHAUST AMOUNTS.
 (5) PROVIDE CONDENSER TIE DOWN DETAIL AS PER 2014 FBC
 WIND LOAD REQUIREMENTS.
 (6) PROVIDE CLARIFICATION FOR KITCHEN EXHAUST.
 RECIRCULATING OR VENTED?? IF VENTED PROVIDE DETAIL WITH
 DUCT SIZE AND EXHAUST AMOUNT.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (7) FORM R405-2014 MUST BE SIGNED BY "OWNER/AGENT"
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-10-22 Cont ID  
Sent By tklarge Date 2016-10-22 Time 08:55 Rev Time 0.00
Received By tklarge Date 2016-10-22 Time 08:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-10-11 Cont ID  
Sent By gjohnson Date 2016-10-11 Time 10:14 Rev Time 0.00
Received By gjohnson Date 2016-10-11 Time 09:38 Sent To  
Notes
2016-10-11 10:31:141ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. THE PLUMBING AND GAS DRAWINGS SHALL BE SIGNED BY THE
 PERSON RESPONSIBLE FOR THE DESIGN. IF BY CONTRACTOR THE
 LIC. NUMBER IS REQUIRED. PER PB AMEND. TO BC 107.2.1
  
 2. CLEAN OUTS ARE REQUIRED AT THE BASE OF ALL SOIL OR
 WASTE STACKS. PER BC RES P3005.2.6
  
 3. PLEASE INDICATE ON RISER WHICH PIPING IS EXISTING
 AND WHITCH IS NEW. PER PB AMEND. TO FBC 107.2.1
  
 4. RISER DIAGRAM DOES NOT MATCH FIST FLOOR PLAN IN THE
 THE BATHROOMS IT SHOWS A SHOWER AND OB THE RISER IT
 SHOWS TUB, IN THE KITCHEN THE RISER SHOWS ONLY ONE SINK
 THE FLOOR PLAN SHOWS A ISLAND SINK AND A MAIN SINK
 PLEASE CLARIFY. PER WPB AMEND. TO FBC 107.2.1

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-09-19 Cont ID  
Sent By cthroop Date 2016-09-19 Time 11:18 Rev Time 0.00
Received By cthroop Date 2016-09-19 Time 11:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-10-04 Cont ID  
Sent By destabro Date 2016-10-05 Time 11:47 Rev Time 0.00
Received By njwira Date 2016-10-04 Time 13:11 Sent To  
Notes
2016-10-04 15:43:4710/4/16- PASSED
  
 SF14-C3 HISTORIC DISTRICT
  
 LOT IS 12,196SQFT.
 FRONT SETBACK MEETS THE CONTEXT OF THE NEIGHBORING
 PROPERTIES
 SIDE SETBACK IS 12FT. MEETING THE 10FT. SETBACK
 REQUIREMENT.
 33FT. REAR SETBACK MEETS THE 15FT. REAR SETBACK
 REQUIREMENT.
 4,873SQFT. MEETS THE 7,878 MAXIMUM ALLOWED FLOOR TO
 AREA RATIO
 2,387SQFT. OF LOT COVERAGE MEETS THE 2,439 MAXIMUM
 ALLOWED LOT COVERAGE
 ONE KITCHEN ONE UNIT
 BUILDING MEETS THE HEIGHT LIMIT.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  