Plan Review Details - Permit 16090159
Plan Review Stops For Permit 16090159
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-12-12 Cont ID  
Sent By skennedy Date 2016-12-12 Time 11:59 Rev Time 0.00
Received By skennedy Date 2016-12-12 Time 11:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-11-22 Cont ID  
Sent By jgomez Date 2016-11-22 Time 10:19 Rev Time 0.00
Received By jgomez Date 2016-11-21 Time 18:34 Sent To  
Notes
2016-11-21 18:38:29NEW SINGLE FAMILY RESIDENCE (R3), SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- ORIGINAL COMMENT:
 1- SHEET A1: GARAGE DOOR DESIGN PRESSURES SHOWN ON THE
 DATA & DESIGN PRESSURE SCHEDULE ARE TOO LOW BASED ON
 THE ADJUSTMENT COEFFICIENT (1.36) AND TABLE R301.2(4)
 FBC-RESIDENTIAL. REVISE AS REQUIRED OR PROVIDE COMPLETE
 ENGINEERING CALCULATIONS.
  
 RESPONSE:
 REVISED DESIGN PRESSURES ARE TOO LOW. CLARIFY WHY USING
 1.21 ADJUSTMENT COEFFICIENT IF DESIGN CRITERIA ON SAME
 PAGE SPECIFIES 1.36 BASED ON THE BUILDING HEIGHT OF THE
 BUILDING. REVISE AS REQUIRED.
  
 2- ORIGINAL COMMENT:
 PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE
 STUCCO SOFFIT SPECIFIED ON DETAIL 1/S4 SHOWING
 COMPLIANCE WITH SEC. R703.1.3 FBC-RESIDENTIAL.
  
 RESPONSE:
 EXPANDED 3/8 IN. RIB LATH REQUIRES 1-3/4 IN. MINIMUM
 PENETRATION INTO HORIZONTAL WOOD FRAMING MEMBERS AS
 REQUIRED BY ASTM C1063 SEC. 7.10.2.3. REVISE AS
 REQUIRED.
  
 3- ENERGY CALCULATIONS SUBMITTED:
 MAIN HOUSE ENERGY CALCULATIONS SUBMITTED:
  
 (A) ORIGINAL COMMENT:
 PROVIDE COMPLETE INFORMATION ON TOP OF FORM, INCLUDING
 OWNER'S NAME AND JURISDICTION #. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 RESPONSE:
 OWNER INFORMATION WAS NOT PROVIDED.
  
 (B) ORIGINAL COMMENT:
 CLEARLY PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING
 THE COMPLIANCE REPORT AS REQUIRED BY SEC. R405.4.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AT ALL. ONLY THE
 SIGNATURE WAS PROVIDED.
  
 (C) ORIGINAL COMMENT:
 CLARIFY WHY THERE ARE 18 OCCUPANTS SPECIFIED ON PAGE 2
 OF 5. TYPICALLY, 18 PEOPLE IS NOT AN USUAL NUMBER OF
 PEOPLE FOR A SINGLE FAMILY RESIDENCE. WHAT'S THE
 PROPOSED USE OF THIS SINGLE FAMILY RESIDENCE. PROVIDE
 DOCUMENTATION THAT VERIFIES THE NUMBER OF PEOPLE
 SPECIFIED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AT ALL. THIS NUMBER OF
 PEOPLE IS NOT TYPICAL FOR A SINGLE FAMILY RESIDENCE.
 PROVIDE DOCUMENTATION THAT SUPPORTS WHY THIS HOUSE IS
 GOING TO BE OCCUPIED WITH 18 PEOPLE. CLEARLY DEFINE THE
 PROPOSED USE OF THIS RESIDENCE. SINCE THIS IS AN
 UNUSUAL SITUATION PLANS WITH PROPOSED NUMBER OF PEOPLE
 WILL BE FORWARDED TO THE BUILDING OFFICIAL FOR REVIEW
 AND APPROVAL. ALSO, INCREASING OR DECREASING THE NUMBER
 OF PEOPLE IN A BUILDING MAY AFFECT THE SIZING OF THE
 HVAC EQUIPMENT. FACTOR THAT MAY AFFECT THE PROPER
 SIZING OF EQUIPMENT IS NOT ALLOWED. SEC. R403.6.1
 FBC-ENERGY CONSERVATION.
  
 NOTE:
 PERSON PREPARING THE ENERGY CALCULATIONS TO COORDINATE
 WITH ARCHITECT OF RECORD TO AVOID MORE
 CONFLICTS/DELAYS. SEE ITEM #4 BELOW.
  
 (D) ORIGINAL COMMENT:
 INSULATION R-VALUE AND TYPE SHOWN ON THE CEILING
 INFORMATION ON PAGE 3 OF 5 DOESN'T MATCH INFORMATION
 SHOWN ON ITEM #10 OF PAGE 1 AND PLANS SUBMITTED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 (E) ORIGINAL COMMENT:
 DOORS INFORMATION SHOWN ON PAGE 3 OF 5 DOESN'T MATCH
 INFORMATION SHOWN ON PLANS AND PRODUCT APPROVALS
 SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014). NOTE: DOOR WITH GLAZING NEEDS TO BE
 INCLUDED IN THE WINDOWS AREA.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AT ALL.
  
  
 CABANA ENERGY CALCULATIONS SUBMITTED:
  
 (A) ORIGINAL COMMENT:
 PROVIDE COMPLETE INFORMATION ON TOP OF FORM, INCLUDING
 OWNER'S NAME AND JURISDICTION #. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 RESPONSE:
 OWNER INFORMATION WAS NOT PROVIDED.
  
 (B) ORIGINAL COMMENT:
 CLEARLY PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING
 THE COMPLIANCE REPORT AS REQUIRED BY SEC. R405.4.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED AT ALL. ONLY THE
 SIGNATURE WAS PROVIDED.
  
 (C) ORIGINAL COMMENT:
 INSULATION R-VALUE AND TYPE SHOWN ON THE CEILING
 INFORMATION ON PAGE 2 OF 4 DOESN'T MATCH INFORMATION
 SHOWN ON ITEM #10 OF PAGE 1 AND ON PLANS SUBMITTED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 (D) ORIGINAL COMMENT:
 THERE IS NO KITCHEN IN THE CABANA. REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 NOTE: LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR
 AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS
 WILL BE REQUIRED WHEN THE ENERGY CALCULATIONS ARE NOT
 USING THE SOFTWARE DEFAULT FACTOR FOR GLAZING.
  
 NEW COMMENT BASED ON THE ENERGY CALCULATIONS SUBMITTED:
 4- ARCHITECT OF RECORD TO CLARIFY THE USE AND NUMBER OF
 PEOPLE FOR WHICH THIS HOUSE IS DESIGNED FOR. ACCORDING
 THE THE ENERGY CALCULATIONS SUBMITTED, THIS HOUSE IS TO
 BE OCCUPIED BY 18 PEOPLE. SEE ITEM #3(C) FOR THE MAIN
 HOUSE ABOVE. THIS IS NOT A TYPICAL NUMBER OF PEOPLE FOR
 A SINGLE FAMILY RESIDENCE. IT IS NOT CLEAR WHAT IS
 GOING TO BE THE USE AND OCCUPANCY OF THIS BUILDING.
 CLEARLY SPECIFY ON PLANS NUMBER OF PEOPLE AND USE OF
 THIS BUILDING FOR PROPER PLAN REVIEW. SINCE THIS IS AN
 UNUSUAL SITUATION PLANS WITH PROPOSED NUMBER OF PEOPLE
 WILL BE FORWARDED TO THE BUILDING OFFICIAL FOR REVIEW
 AND APPROVAL. SEC. 102.2 CITY AMENDMENTS.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 (A) ORIGINAL COMMENT:
 BALCONIES UNDERLAYMENT THAT IS DESIGNED TO RECEIVE TILE
 OR MARBLE AS SPECIFIED ON THE FINISH SCHEDULE ON SHEET
 A7. NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL SPECIFIC
 ASSEMBLY TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 SELECTED SYSTEM NO C-36 FROM HYDROSTOP FLORIDA PRODUCT
 APPROVAL FL20663 SUBMITTED IS NOT A DESIGNED
 UNDERLAYMENT TO RECEIVE TILE/MARBLE. SEE ROOF COVER
 NOTES 13 AND 14 AS REQUIRED BY SYSTEM NO C-36. NEED TO
 PROVIDE A PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE
 TILE/MARBLE.
  
 (B) GARAGE DOORS. NOTE: GARAGE DOORS FLORIDA PRODUCT
 APPROVAL FL 16546.30 SUBMITTED WILL BE REVIEWED WHEN
 THE GARAGE DOOR DESIGN PRESSURES ARE CLARIFIED. SEE
 ITEM #1 ABOVE.
  
 NEW COMMENTS:
 (C) PEEL AND STICK UNDERLAYMENT FOR METAL ROOF AS
 SPECIFIED ON PLANS. LEAKBARRIER FAST 90 OF FLORIDA
 PRODUCT APPROVAL FL 10450-R8 SUBMITTED CAN NOT BE USED
 FOR METAL ROOF. SEE TABLE 1 OF FL10450-R8.
  
 (D) JAMES HARDIE CEMENT SIDING. PROVIDE COMPLETE
 APPROVED PRODUCT APPROVAL FOR THE PROPOSED INSTALLATION
 (WOOD FRAME AND CONCRETE BLOCK AS SHOWN ON PLANS).
 INFORMATION SUBMITTED DOESN'T HAVE A FLORIDA PRODUCT
 APPROVAL OR MIAMI-DADE NOA. IF THERE IS NOT A CURRENT
 APPROVED PRODUCT APPROVAL, THEN MANUFACTURER MAY APPLY
 FOR LOCAL PRODUCT APPROVAL. CONTACT ME FOR MORE
 INFORMATION ABOUT LOCAL PRODUCT APPROVAL.
  
 6- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 7- TRUSS PACKAGE SUBMITTED: (NOTE: THERE IS NO NEED TO
 RE-SUBMIT THE TRUSS PACKAGE. THE TRUSS PACKAGE MAY BE
 DELIVERED (AFTER REQUIRED INFORMATION IS PROVIDED) TO
 THE BUILDING INSPECTOR AT TIME OF FRAMING INSPECTION).
  
 A) ORIGINAL COMMENT:
 EACH OF THE DRAWINGS OF THE TRUSS PACKAGE NEED TO HAVE
 THE TITLE BLOCK OF THE TRUSS ENGINEER AS REQUIRED BY
 FAC 61G15-31.003.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE TO EXPEDITE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-09-22 Cont ID  
Sent By jgomez Date 2016-09-20 Time 18:08 Rev Time 0.00
Received By jgomez Date 2016-09-20 Time 17:12 Sent To  
Notes
2016-09-20 18:13:06NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
 NOTE: THIS MAY DONE LATER WHEN THE PERMIT IS READY TO
 BE ISSUED.
  
 2- PROVIDE SITE DRAINAGE PLAN AS REQUIRED BY SEC.
 R401.3 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 3- SHEET A1: GARAGE DOOR DESIGN PRESSURES SHOWN ON THE
 DATA & DESIGN PRESSURE SCHEDULE ARE TOO LOW BASED ON
 THE ADJUSTMENT COEFFICIENT (1.36) AND TABLE R301.2(4)
 FBC-RESIDENTIAL. REVISE AS REQUIRED OR PROVIDE COMPLETE
 ENGINEERING CALCULATIONS.
  
 4- SETBACK DIMENSIONS SHOWN ON THE SURVEY SUBMITTED
 DON'T MATCH SETBACK DIMENSIONS SHOWN ON SHEET A2.
 REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 5- SHEET A3 AND S1 SHOWS 1.5" DROP FROM THE FINISH
 CONCRETE SLAB TO THE FINISHED GRADE. PROVIDE COMPLETE
 INFORMATION SHOWING COMPLIANCE WITH THE CLEARANCE FOR
 TERRMITE INSPECTION SEC. R318.7 AND HEIGHT ABOVE
 FINISHED GRADE SEC. R404.1.6 FBC-RESIDENTIAL, 5TH
 EDITION (2014). REVISE AS REQUIRED.
  
 6- NEED TO SPECIFY ATTIC ACCESS BY THE MASTER BATHROOM,
 EAST GARAGE AREA AND REAR LANAI AS REQUIRED BY SEC.
 R807 FBC-RESIDENTIAL.
  
 7-GARAGE DOOR LEADING TO THE MAIN HOUSE NEEDS TO HAVE A
 SELF CLOSING DEVICE AS REQUIRED BY SEC. R302.5.1
 FBC-RESIDENTIAL.
  
 8- GARAGE STRUCTURAL BUCK DETAIL DETAIL 1/A11: PROVIDE
 COMPLETE SPECIFICATIONS FOR FASTENER TYPE, SIZE AND
 SPACING. STRUCTURAL BUCK ATTACHMENT IS THE
 RESPONSIBILITY OF THE DESIGNER OF RECORD NOT THE GARAGE
 DOOR MANUFACTURER. SEC. R301.1 FBC-RESIDENTIAL.
  
 9-PROVIDE SPRAY FOAM INSULATION ICC EVALUATION REPORT
 SPECIFIED ON DETAIL 1/S4 TO SHOW COMPLIANCE WITH SEC.
 R316 FBC-RESIDENTIAL. NOTE: REPORT TO BE REVIEWED AND
 APPROVED BY DESIGNER OF RECORD PRIOR TO SUBMITTAL TO
 THIS OFFICE.
  
 10- PROVIDE COMPLETE DETAIL AND SPECIFICATIONS FOR THE
 STUCCO SOFFIT SPECIFIED ON DETAIL 1/S4 SHOWING
 COMPLIANCE WITH SEC. R703.1.3 FBC-RESIDENTIAL.
  
 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR:
 A) THE-LANAI CEILING CONSTRUCTION. SEC. R301.1
 FBC-RESIDENTIAL.
  
 B) THE ENTRY BALCONIES CEILING CONSTRUCTION. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 12- DETAIL 1/S4: PROVIDE COMPLETE INFORMATION SHOWING
 COMPLIANCE WITH THE CLEARANCE FOR TERMITE INSPECTION
 SEC. R318.7 AND HEIGHT ABOVE FINISHED GRADE SEC.
 R404.1.6 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 13- CABANA FOUNDATION PLANS SHOWN ON SHEET S1 IS
 MISSING THE FOOTING. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL.
  
 14- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 INSTALLATION OF GABLE END TRUSS AND BALCONY SOFFIT AS
 SHOWN ON DETAIL 2/S4. SPECIFY ALL FRAMING MEMBERS AND
 CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL.
  
 15- WALL SECTIONS ON SHEET S4: SPECIFY FIREBLOCKING AS
 REQUIRED BY SEC. R302.11 FBC-RESIDENTIAL.
  
 16- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 SECOND FLOOR DRAFSTOPPING AS REQUIRED BY SEC. R302.12
 FBC-RESIDENTIAL.
  
 17- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 1 HOUR FIRE RATED UNDERSIDE OF THE CABANA SOFFIT AS
 REQUIRED BY TABLE R302.1(1) FBC-RESIDENTIAL.
  
 18- STRUCTURAL ENGINEER WHO SIGNED AND SEALED THE
 STRUCTURAL DRAWINGS NEED TO UPDATE THE ENGINEERING FIRM
 CERTIFICATE OF AUTHORIZATION (#9318) WITH DBPR AS
 REQUIRED BY FAC 61G15-23.00219.
  
 19- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION AND INSTALLATION OF THE STAIRWAY SHOWING
 COMPLIANCE WITH SEC. R311.7 FBC-RESIDENTIAL.
  
 20- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION AND INSTALLATION OF ALL HANDRAILS, AND
 GUARDRAILS SHOWING COMPLIANCE WITH THE LIVE LOADS OF
 TABLE R301.5 FBC-RESIDENTIAL AND ALL THE REQUIREMENTS
 OF SEC. R311.7.8 AND SEC. R312.1 FBC-RESIDENTIAL.
  
 21- ENERGY CALCULATIONS SUBMITTED:
 MAIN HOUSE:
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME AND JURISDICTION #. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 B) CLEARLY PROVIDE THE NAME OF THE INDIVIDUAL
 COMPLETING THE COMPLIANCE REPORT AS REQUIRED BY SEC.
 R405.4.2 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 C) OWNER/AGENT NEEDS TO CERTIFY AT BOTTOM OF FORM AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 D) CLARIFY WHY THERE ARE 18 OCCUPANTS SPECIFIED ON PAGE
 2 OF 5. TYPICALLY, 18 PEOPLE IS NOT AN USUAL NUMBER OF
 PEOPLE FOR A SINGLE FAMILY RESIDENCE. WHAT'S THE
 PROPOSED USE OF THIS SINGLE FAMILY RESIDENCE. PROVIDE
 DOCUMENTATION THAT VERIFIES THE NUMBER OF PEOPLE
 SPECIFIED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 E) INSULATION R-VALUE AND TYPE SHOWN ON THE CEILING
 INFORMATION ON PAGE 3 OF 5 DOESN'T MATCH INFORMATION
 SHOWN ON ITEM #10 OF PAGE 1 AND PLANS SUBMITTED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 F) DOORS INFORMATION SHOWN ON PAGE 3 OF 5 DOESN'T MATCH
 INFORMATION SHOWN ON PLANS AND PRODUCT APPROVALS
 SUBMITTED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014). NOTE: DOOR WITH GLAZING NEEDS TO BE
 INCLUDED IN THE WINDOWS AREA.
  
 G) BUILDER TO COMPLETE THE EPL DISPLAY CARD AS REQUIRED
 BY SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 H) COMPLETE THE INSPECTION CHECKLIST TABLE 402.4.1.1
 SUBMITTED. SEC. R405.4.2 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
  
 CABANA:
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME AND JURISDICTION #. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 B) CLEARLY PROVIDE THE NAME OF THE INDIVIDUAL
 COMPLETING THE COMPLIANCE REPORT AS REQUIRED BY SEC.
 R405.4.2 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 C) OWNER/AGENT NEEDS TO CERTIFY AT BOTTOM OF FORM AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 D) INSULATION R-VALUE AND TYPE SHOWN ON THE CEILING
 INFORMATION ON PAGE 2 OF 4 DOESN'T MATCH INFORMATION
 SHOWN ON ITEM #10 OF PAGE 1 AND ON PLANS SUBMITTED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 E) THERE IS NO KITCHEN IN THE CABANA. REVISE AS
 REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 F) BUILDER TO COMPLETE THE EPL DISPLAY CARD AS REQUIRED
 BY SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 G) COMPLETE THE INSPECTION CHECKLIST TABLE 402.4.1.1
 SUBMITTED. SEC. R405.4.2 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 NOTE: LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR
 AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS
 WILL BE REQUIRED WHEN THE ENERGY CALCULATIONS ARE NOT
 USING THE SOFTWARE DEFAULT FACTOR FOR GLAZING.
  
 22- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) ROOF TILE. PROVIDE COMPLETE INFORMATION FOR THE
 SPECIFIC ROOF TILE TO BE INSTALLED. ONLY THE FLORIDA
 PRODUCT APPROVAL COVER PAGE FL7849-R9 WAS SUBMITTED.
 ALSO, NEED TO PROVIDE TWO COPIES. ONLY ONE WAS
 SUBMITTED.
  
 B) PEEL-N-STICK ROOF TILE UNDERLAYMENT AS SPECIFIED ON
 DRAWINGS.
  
 C) BALCONIES UNDERLAYMENT THAT IS DESIGNED TO RECEIVE
 TILE OR MARBLE AS SPECIFIED ON THE FINISH SCHEDULE ON
 SHEET A7. NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL
 SPECIFIC ASSEMBLY TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
  
 D) CASEMENT WINDOWS AS SPECIFIED ON PLANS. NEED PRODUCT
 APPROVAL THAT COVERS WINDOW HEIGHT SPECIFIED FOR DOUBLE
 WINDOWS "A" AND "B". NOA 15-0420.11 SUBMITTED DOESN'T
 COVER THOSE SIZES.
  
 E) GARAGE DOORS. NOTE: COORDINATE DESIGN PRESSURES WITH
 REVISED DESIGN PRESSURES REQUIRED ON ITEM # 3 ABOVE.
  
 F) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 G) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR OR LIST THE FLORIDA PRODUCT APPROVAL NUMBER
 NEXT TO EACH SPECIFIED CONNECTOR.
  
 23- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 24- ENGINEER OF RECORD TO CLEARLY SPECIFY ALL LIVE
 LOADS, DEAD LOAD ( SECOND FLOOR, BALCONIES, ROOF, ETC).
 SEC.R301.1 FBC-RESIDENTIAL. AND INCLUDE THE ATTIC LIVE
 LOADS AS REQUIRED BY NOTES "B" AND "G" OF TABLE R301.5
 FBC-RESIDENTIAL.
  
 25- STRUCTURAL PLANS AND TRUSS PLANS NEED TO BE
 COORDINATED. FRAMING PLANS DON'T MATCH. THERE ARE AREAS
 WHERE TRUSS PLANS CALL FOR BEARING WALLS, WHILE
 STRUCTURAL ENGINEER PLANS CALL FOR GIRDER TRUSSES.
 NOTE: ALSO COORDINATE ALL BEARING WALLS, LOAD BEARING
 POINTS AND RESPECTIVE FOOTINGS. SEC. R301.1
 FBC-RESIDENTIAL. REVISE PLANS TO MATCH.
  
 26- TRUSS PACKAGE SUBMITTED:
 A) TRUSS ENGINEER TO SIGN AND SEAL TRUSS LAYOUT AS
 REQUIRED BY FAC 61G15-23.002.
 B) TRUSS PACKAGE COVER PAGE TO HAVE ENGINEER'S ORIGINAL
 SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. IT LOOKS
 LIKE SIGNATURE ON COVER R PAGE SUBMITTED IS A COPY.
 C) TRUSS PACKAGE COVER PAGE TO HAVE THE INFORMATION OF
 THE STRUCTURAL ENGINEER OF RECORD AS REQUIRED BY FAC
 61G15-31.003.
 D) EACH OF THE DRAWINGS OF THE TRUSS PACKAGE NEED TO
 HAVE THE TITLE BLOCK OF THE TRUSS ENGINEER AS REQUIRED
 BY FAC 61G15-31.003.
 E) TRUSS PACKAGE TO BE REVIEWED AND APPROVED BY THE
 ENGINEER OF RECORD AS REQUIRED BY FAC 61G15-30.005.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE TO EXPEDITE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-12-12 Cont ID  
Sent By mvaldes Date 2016-12-12 Time 10:04 Rev Time 0.00
Received By mvaldes Date 2016-12-12 Time 09:26 Sent To  
Notes
2016-12-12 10:10:283RD REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO"S
  
 1] PROPER WORKING SPACE FOR A/C DISCONNECTS REQUIRED.
 FBC-R SECTION E3405.1.
 2] SERVICE GFCI RECEPTACLE REQUIRED BY COMPRESSOR UNIT.
 FBC-R SECTION E3901.11.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-11-28 Cont ID  
Sent By mvaldes Date 2016-11-28 Time 17:08 Rev Time 0.00
Received By mvaldes Date 2016-11-28 Time 15:25 Sent To  
Notes
2016-11-28 17:10:15JOB PERMIT NUMBER: 16090159
 JOB ADDRESS: 234 DESOTA RD (NEW RESIDENCE)
 WEST PALM BEACH FLORIDA 33405
 DATE: NOVEMBER 28, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC
 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA
 BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH
 AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED.
  
 1] NOT ADDRESSED, PROVIDE FPL AVAILABLE FAULT CURRENT
 LETTER & SHOW AIC CALCULATIONS TO VERIFY SHORT CIRCUIT
 RATING OF ELECTRICAL EQUIPMENT. FBC-R SECTIONS E3404.2
 & E3404.3
  
 2] ADDRESSED
  
 3] NOT ADDRESSED, PROVIDE A NEUTRAL LOAD CALCULATION
 SINCE YOUR LOWERING YOUR SERVICE FEEDER CONDUCTOR.
 FBC-R SECTION E3704.3
  
 4] ADDRESSED
  
 5] ADDRESSED
  
 6] NOT ADDRESSED, SHOW 42 CIRCUIT PANEL 1A & 1B ON THE
 ELECTRICAL FLOOR PLAN. FBC 107
  
 7] ADDRESSED
  
 8] ADDRESSED
  
 9] ADDRESSED
  
 10] NOT ADDRESSED, PLEASE LABEL CIRCUIT DESIGNATION ON
 THE FLOOR PLAN TO MATCH PANEL SCHEDULE. FBC 107
  
 11] ADDRESSED
  
 12] ADDRESSED
  
 13] ADDRESSED
  
 14] SEMI ADDRESSED, CLARIFY SMOKE/CARBON ALARM DEVICE
 TO BE LISTED FOR INSTALLATION NEAR COOKING APPLIANCES
 WITH A SILENCEABLE FEATURE OR REMOVE DEVICE FROM THIS
 LOCATION. NFPA 72 SECTION 29.8.3.4
  
 15] ADDRESSED
  
 16] ADDRESSED
  
 17] FEEL FREE TO CONTACT ME SHOULD YOU HAVE QUESTIONS
 OR CONCERNS
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER
 RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES
 WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER
 QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME
 DIRECTLY.
  
 2ND REVIEW FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-09-27 Cont ID  
Sent By vperez Date 2016-09-27 Time 09:20 Rev Time 0.00
Received By vperez Date 2016-09-27 Time 08:44 Sent To  
Notes
2016-09-27 09:20:42INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. PROVIDE AIC CALCULATIONS FOR NEW SERVICE SHOWN AND
 LABEL SERVICE EQUIPMENT AND PANEL BOARDS WITH AIC
 RATINGS. FBC 107.3.5
 2. PLEASE NOTE THAT THE ELECTRICAL SERVICE SHOWN IS NOT
 A TYPICAL FIELD INSTALLATION. CLARIFY IF THERE ARE 2
 -150AMP MAIN DISCONNECTS INSTEAD OF 1- 300AMP.
 3. SHOW SERVICE CONDUCTORS. FBC RES E3603
 4. GENERAL NOTE TO INDICATED REQUIRED SEPARATE PERMITS
 FOR LOW VOLTAGE SYSTEMS, GENERATOR AND POOL. FBC
 107.3.5
 5. SHOW AN INTERSYSTEM BONDING TERMINAL AT THE SERVICE
 PER FBC RES E3609.3
 6. SHOW ON FLOOR PLAN LOCATION OF SERVICE EQUIPMENT.
 LABEL EQUIPMENT AS RATED FOR SERVICE ENTRANCE AND
 PROPER NEMA 3R RATING. FBC 107.3.5
 7. SHOW ALL EXTERIOR RECEPTACLE AT REAR PROTECTED BY
 GFCI DEVICE. FBC RES E3902.3
 8. RECEPTACLE AT WALL SPACE IN BAR AREA WITHIN 6FT OF
 SINK TO BE LABELED AS GFCI PROTECTED. FBC RES E3902.7
 9. SHOW JACUZZI AND GARAGE DOOR OPENER DEVICES TO BE
 PROTECTED BY GFCI BREAKER TO BE READILY ACCESSIBLE.
 LOADS FOR THESE ARE NOT REFLECTED ON PANEL SCHEDULES.
 10. PLEASE NOTE THAT ALL CIRCUITS? DESIGNATION AT THE
 PANELBOARDS MUST INDICATE WHAT AREA SPECIFICALLY OF THE
 HOUSE IT?S SERVICING. SHOW ON PANEL SCHEDULE. GENERAL
 LIGHTING DOES NOT MEET THESE REQUIREMENTS. EXAMPLE,
 LABEL BEDROOM 1, BEDROOM 2 ETC.?NEC 408.4 FIELD ID
 REQUIRED. FBC 107.3.5
 11. PROVIDE A NOTE PER FBC ENERGY CONSERVATION CODE TO
 INDICATE; 75% OF LAMPS TO HIGH EFFICACY LAMPS.
 12. PLEASE SHOW ON PANELBOARD 20A CIRCUITS REQUIRED FOR
 DINING ROOM RECEPTACLES AND BATHROOM RECEPTACLES. FBC
 RES E3703.2 AND 4
 13. BRANCH CIRCUIT CONDUCTOR SIZE SHOWN FOR POOL PUMP
 EQUIP, ALL AHU UNITS ARE UNDERSIZED PER NEC 310.15B16
 TABLE OF AMPACITIES
 14. SHOW ALL SMOKE DETECTOR OUTSIDE OF BEDROOMS TO BE
 CO(CARBON MONOXIDE) PER FBC RES 315, MAINTAIN REQUIRED
 DISTANCES FROM KITCHEN APPLIANCES.
 15. SHOW ATTIC ACCESS LIGHTING ON PLANS. FBC 107.3.5
 16. PLEASE TRANSFER GENERAL ELECTRICAL NOTES ON FIRST
 SHEET A1 TO SHEET A12. FBC 107.3.5
 17. FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY
 QUESTIONS OR CONCERNS.
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-10-05 Cont ID  
Sent By tklarge Date 2016-10-05 Time 06:09 Rev Time 0.00
Received By tklarge Date 2016-10-05 Time 06:09 Sent To  
Notes
2016-10-05 06:26:281) A SEPARATE PERMIT IS REQUIRED FOR THE GAS
 INSTALLATION.
 2) GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 3) A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO
 PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT
 REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB
 AMEND. TO FBC SEC.107.2.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-12-12 Cont ID  
Sent By skennedy Date 2016-12-12 Time 14:32 Rev Time 0.00
Received By skennedy Date 2016-12-05 Time 12:46 Sent To  
Notes
2016-12-06 12:47:01R32

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-29 Cont ID  
Sent By ccole Date 2016-11-29 Time 07:13 Rev Time 0.00
Received By ccole Date 2016-11-01 Time 12:54 Sent To  
Notes
2016-11-01 12:54:19R32

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-10-17 Cont ID  
Sent By ccole Date 2016-10-17 Time 12:16 Rev Time 0.00
Received By ccole Date 2016-09-07 Time 13:04 Sent To  
Notes
2016-09-07 13:04:22R20

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2016-12-16 Cont ID  
Sent By gdorsan Date 2016-12-16 Time 10:52 Rev Time 0.00
Received By gdorsan Date 2016-12-16 Time 10:51 Sent To  
Notes
2016-12-16 10:51:53PASSED BY SAK GD

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-11-23 Cont ID  
Sent By jgomez Date 2016-11-23 Time 07:02 Rev Time 0.00
Received By jgomez Date 2016-11-23 Time 06:51 Sent To  
Notes
2016-11-23 07:02:341- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
 NOTE: THIS MAY DONE LATER WHEN THE PERMIT IS READY TO
 BE ISSUED.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-09-20 Cont ID  
Sent By jgomez Date 2016-09-20 Time 18:13 Rev Time 0.00
Received By jgomez Date 2016-09-20 Time 18:13 Sent To  
Notes
2016-11-23 07:02:081- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
 NOTE: THIS MAY DONE LATER WHEN THE PERMIT IS READY TO
 BE ISSUED.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-12-12 Cont ID  
Sent By skennedy Date 2016-12-12 Time 11:59 Rev Time 0.00
Received By skennedy Date 2016-12-12 Time 11:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-11-29 Cont ID  
Sent By ccole Date 2016-11-29 Time 06:49 Rev Time 0.00
Received By ccole Date 2016-11-28 Time 17:24 Sent To  
Notes
2016-11-29 07:10:092ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16090159
 11/29/16
  
 1) SPECS HAVE BEEN SUBMITTED FOR THE CARRIER FX4D AIR
 HANDLER TO VERIFY CAPACITIES. PLEASE SUBMIT SPECS FOR
 THE 5-TON FB4C AIR HANDLER.
  
 2) THE AC CALCULATIONS ARE LISTING 18 OCCUPANTS FOR THE
 HOUSE. PLEASE REVIEW ACCA MANUAL J. INTERNAL GAINS
 CRITERIA FOR SIZING LOADS DETERMINE OCCUPANTS BASED ON
 THE NUMBER OF BEDROOMS PLUS ONE, WHICH WOULD BE 6 FOR
 THE MAIN HOUSE- PLEASE CORRECT.
  
 3) IF PROVIDING A FL. PRODUCT APPROVAL FOR CONDENSER
 ANCHORING CLIPS, PLEASE SUBMIT THE ENTIRE DOCUMENT
 INCLUDING THE COVER SHEET TO VERIFY- RULE 9N-3 FLORIDA
 DEPT. OF COMMUNITY AFFAIRS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-10-17 Cont ID  
Sent By ccole Date 2016-10-17 Time 11:47 Rev Time 0.00
Received By ccole Date 2016-10-17 Time 09:37 Sent To  
Notes
2016-10-17 12:11:241ST REVIEW FBC-2014 RESDIENTIAL MECHANICAL
 PERMIT #16090159
 10/17/16
  
 1) THE PLANS SHOW THE TOTAL SUPPLY CFMS EXCEEDING THE
 CAPACITIES OF THE SELECTED SYSTEMS: THE 2095 CFMS SHOWN
 ON THE 1ST FLOOR WOULD EXCEED THE CAPACITIY OF AC-1
 WHICH IS A 4-TON SYSTEM, AND THE 1610 CFMS SHOWN ON THE
 2ND FLOOR WOULD EXCEED THE CAPACITY OF AC-2 WHICH IS A
 3-TON SYSTEM.
  
 2) PLEASE UPDATE THE CODE REFERENCE AND SECTION NUMBER
 FOR THE C/U TIE DOWN.
  
 3) REFER TO TABLE M1507.4 RESIDENTIAL AND PROVIDE A
 KITCHEN EXHAUST SYSTEM AND THE EXHAUST VENTILATION
 RATE. PROVIDE A SUBMITTAL AND EQUIPMENT SCHEDULE FOR
 THE RANGE HOOD IF APPLICABLE- SEE SECTION M1503.
  
 4) THE ENERGY FORM R405-2014 IS LACKING THE OWNER'S
 NAME, OWNER'S SIGNATURE, THE JURISDICTION NUMBER, AND
 THE COMPLETED AIR BARRIER AND INSULATION CHECKLIST.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-11-19 Cont ID  
Sent By tklarge Date 2016-11-19 Time 04:14 Rev Time 0.00
Received By tklarge Date 2016-11-19 Time 03:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-10-05 Cont ID  
Sent By tklarge Date 2016-10-05 Time 06:09 Rev Time 0.00
Received By tklarge Date 2016-10-05 Time 05:41 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2016-12-12 Cont ID  
Sent By skennedy Date 2016-12-12 Time 11:58 Rev Time 0.00
Received By skennedy Date 2016-12-12 Time 11:58 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2016-11-23 Cont ID  
Sent By jgomez Date 2016-11-23 Time 07:04 Rev Time 0.00
Received By jgomez Date 2016-11-23 Time 07:04 Sent To  
Notes
2016-11-23 07:06:451- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 (A) ORIGINAL COMMENT:
 BALCONIES UNDERLAYMENT THAT IS DESIGNED TO RECEIVE TILE
 OR MARBLE AS SPECIFIED ON THE FINISH SCHEDULE ON SHEET
 A7. NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL SPECIFIC
 ASSEMBLY TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 SELECTED SYSTEM NO C-36 FROM HYDROSTOP FLORIDA PRODUCT
 APPROVAL FL20663 SUBMITTED IS NOT A DESIGNED
 UNDERLAYMENT TO RECEIVE TILE/MARBLE. SEE ROOF COVER
 NOTES 13 AND 14 AS REQUIRED BY SYSTEM NO C-36. NEED TO
 PROVIDE A PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE
 TILE/MARBLE.
  
  
 APPROVED PRODUCT APPROVALS:
 A) ROOF TILE NOA 12-0222.03.
  
 B) ROOF TILE ADHESIVE FL6332-R7.
  
 C) ROOF TILE UNDERLAYMENT. LEAKBARRIER FAST90
 FL10450-R8.
  
 D) ROOF TILE METAL CHANNEL FL5374-R4.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2016-09-21 Cont ID  
Sent By jgomez Date 2016-09-21 Time 17:22 Rev Time 0.00
Received By jgomez Date 2016-09-21 Time 17:22 Sent To  
Notes
2016-09-21 17:23:441- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) ROOF TILE. PROVIDE COMPLETE INFORMATION FOR THE
 SPECIFIC ROOF TILE TO BE INSTALLED. ONLY THE FLORIDA
 PRODUCT APPROVAL COVER PAGE FL7849-R9 WAS SUBMITTED.
 ALSO, NEED TO PROVIDE TWO COPIES. ONLY ONE WAS
 SUBMITTED.
  
 B) PEEL-N-STICK ROOF TILE UNDERLAYMENT AS SPECIFIED ON
 DRAWINGS.
  
 C) BALCONIES UNDERLAYMENT THAT IS DESIGNED TO RECEIVE
 TILE OR MARBLE AS SPECIFIED ON THE FINISH SCHEDULE ON
 SHEET A7. NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL
 SPECIFIC ASSEMBLY TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
  
  
  
 -FOAM ADHESIVE FL6332-R7 SUBMITTED.

Review Stop Z ZONING
Rev No 3 Status P Date 2016-12-12 Cont ID  
Sent By awooten Date 2016-12-12 Time   Rev Time 0.00
Received By awooten Date 2016-12-12 Time   Sent To  
Notes
2016-12-12 14:19:23***ZONING PROVISO***
  
 PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY,
 THE FOLLOWING CONDITIONS SHALL BE ADDRESSED:
  
 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN,
 SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW.
 2 THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED
 LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL
 LANDSCAPE INSPECTION.
  
 PLEASE CONTACT ME IF YOU HAVE ANY QUESTIONS.
  
 ALANA WOOTEN
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2016-11-17 Cont ID  
Sent By awooten Date 2016-11-17 Time 09:24 Rev Time 0.00
Received By awooten Date 2016-11-17 Time 09:21 Sent To  
Notes
2016-11-17 09:23:36******ZONING FAILED*******
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE AND
 IRRIGATION PLAN IN A SEPARATE LANDSCAPE PERMIT SHOWING
 COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR.
  
 PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS.
  
 ALANA WOOTEN
 PLANNING AND ZONING
 ASSOCIATE PLANNER
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By awooten Date 2016-09-12 Time   Rev Time 0.00
Received By awooten Date 2016-09-12 Time 08:31 Sent To  
Notes
2016-09-14 14:56:49*****ZONING REVIEW FAILED********
  
 SETBACK ENCROACHMENTS:
  
 STRUCTURAL INTRUSIONS. STRUCTURAL OVERHANGS, INCLUDING
 BUT NOT LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES,
 AND ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER
 THAN THREE FEET INTO ANY SETBACK.
  
 LANDSCAPING:
  
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
  
 SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
  
 PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS.
  
 ALANA WOOTEN
 PLANNING AND ZONING
 ASSOCIATE PLANNER
 561-822-1449
 [email protected]
  