Plan Review Details - Permit 16081342
Plan Review Stops For Permit 16081342
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-20 Cont ID  
Sent By jwitmer Date 2016-09-20 Time 07:09 Rev Time 0.00
Received By jwitmer Date 2016-09-20 Time 07:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-09-07 Cont ID  
Sent By jwitmer Date 2016-09-07 Time 06:59 Rev Time 0.00
Received By jwitmer Date 2016-09-07 Time 06:46 Sent To  
Notes
2016-09-07 06:59:20BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16081342
 ADD: 1200 S. FLAGLER DR. SUITE # 1201
 CONT: DEAN MITCHELL RESTORATION
 TEL: 561-881-8567
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 07/ 2016
 ACTION: DENIED
  
 1) SHEET A-1.01 INDICATES NEW FLOOR FINISHES AND IN THE
 FINISH SCHEDULE THERE IS ONLY ONE CATEGORY (F-1).
 PLEASE NOTE IN THE GUEST BATH THE FLOOR FINISH IS
 LABELED (F), IS THIS A TYPO? 107.2.1.3. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 2A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-09-07 Cont ID  
Sent By vperez Date 2016-09-07 Time 14:57 Rev Time 0.00
Received By vperez Date 2016-09-07 Time 14:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-09-02 Cont ID  
Sent By pleduc Date 2016-09-02 Time   Rev Time 0.00
Received By pleduc Date 2016-09-02 Time 11:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-20 Cont ID  
Sent By jwitmer Date 2016-09-20 Time 07:10 Rev Time 0.00
Received By jwitmer Date 2016-09-16 Time 13:16 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-10 Cont ID  
Sent By tklarge Date 2016-09-10 Time 12:43 Rev Time 0.00
Received By tklarge Date 2016-08-31 Time 11:02 Sent To  
Notes
2016-09-01 11:02:29B23

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-09-07 Cont ID  
Sent By jwitmer Date 2016-09-07 Time 06:52 Rev Time 0.00
Received By jwitmer Date 2016-09-07 Time 06:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-09-19 Cont ID  
Sent By jwitmer Date 2016-09-20 Time 07:10 Rev Time 0.00
Received By ccole Date 2016-09-19 Time 17:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-07 Cont ID  
Sent By ccole Date 2016-09-07 Time 15:55 Rev Time 0.00
Received By ccole Date 2016-09-07 Time 15:55 Sent To  
Notes
2016-09-07 15:56:371ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16081342
 9/7/16
  
 1) PROVIDE MECHANICAL PLANS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status N Date 2016-09-19 Cont ID  
Sent By jwitmer Date 2016-09-19 Time 16:24 Rev Time 0.00
Received By jwitmer Date 2016-09-19 Time 16:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-09-10 Cont ID  
Sent By tklarge Date 2016-09-10 Time 12:42 Rev Time 0.00
Received By tklarge Date 2016-09-10 Time 12:23 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***