Plan Review Details - Permit 16081161
Plan Review Stops For Permit 16081161
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-09-21 Cont ID  
Sent By jwitmer Date 2016-09-21 Time 13:18 Rev Time 0.00
Received By jwitmer Date 2016-09-21 Time 13:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-09-15 Cont ID  
Sent By jwitmer Date 2016-09-15 Time 13:41 Rev Time 0.00
Received By jwitmer Date 2016-09-15 Time 13:41 Sent To  
Notes
2016-09-15 13:44:52BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16081161
 ADD: 3300 BROADWAY
 CONT: GULFSTREAM ROOFING
 TEL: 786-357-5327
 E-MAIL: ??????? NOT GIVEN/ WE COMMUNICATE BY E-MAIL
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. SEPT. 15/2016
 ACTION: DENIED
  
  
 NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH RESPECT
 TO EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A
 LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO
 ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND
 ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY
 THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A
 CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN
 EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS,
 FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
 NO CHANGE IN
 PAPERWORK!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
  
 1) THE PRODUCT APPROVAL SUBMITTED IS 13-1022.15/ GAF
 CONVENTIONAL BUILT-UP ROOF SYSTEM FOR WOOD DECKS. 16
 PAGES. PLEASE NOTE THE WRITE UP FROM A+ENGINEERING
 TESTING LABS INDICATES THE NOA : 14-1030.02 SUBSYSTEM
 PAGES 26& 27. THE WRONG PRODUCT APPROVAL SUBMITTED OR
 THE WRONG ENGINEERING SUBMITTED? 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE
 CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND
 DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS,
 FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND
 RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED.
 PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE
 COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE
 SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR
 ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH
 THE CONSTRUCTION DOCUMENTS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-30 Cont ID  
Sent By jwitmer Date 2016-08-30 Time 06:27 Rev Time 0.00
Received By jwitmer Date 2016-08-30 Time 06:13 Sent To  
Notes
2016-08-30 06:27:22BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16081161
 ADD: 3300 BROADWAY
 CONT: GULFSTREAM ROOFING
 TEL: 786-357-5327
 E-MAIL: ??????? NOT GIVEN/ WE COMMUNICATE BY E-MAIL
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. AUGUST 30/2016
 ACTION: DENIED
  
 1) THE PRODUCT APPROVAL SUBMITTED IS 13-1022.15/ GAF
 CONVENTIONAL BUILT-UP ROOF SYSTEM FOR WOOD DECKS. 16
 PAGES. PLEASE NOTE THE WRITE UP FROM A+ENGINEERING
 TESTING LABS INDICATES THE NOA : 14-1030.02 SUBSYSTEM
 PAGES 26& 27. THE WRONG PRODUCT APPROVAL SUBMITTED OR
 THE WRONG ENGINEERING SUBMITTED? 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE
 CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND
 DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS,
 FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND
 RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED.
 PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE
 COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE
 SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR
 ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH
 THE CONSTRUCTION DOCUMENTS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-15 Cont ID  
Sent By jwitmer Date 2016-09-15 Time 13:44 Rev Time 0.00
Received By jwitmer Date 2016-09-14 Time 13:28 Sent To  
Notes
2016-09-14 13:28:49RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-30 Cont ID  
Sent By jwitmer Date 2016-08-30 Time 06:27 Rev Time 0.00
Received By jwitmer Date 2016-08-29 Time 16:26 Sent To  
Notes
2016-08-29 16:26:58JWITMER