Plan Review Details - Permit 16081032
| Plan Review Stops For Permit 16081032 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-09-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-17 |
Time |
03:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-17 |
Time |
03:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-08-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-08-26 |
Time |
06:22 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-08-26 |
Time |
06:08 |
Sent To |
|
|
| Notes |
| 2016-08-26 06:05:33 | 1) INDICATE ON THE PLAN THE TYPE OF BACKER BOARD TO BE | | | INSTALLED IN THE SHOWER. COMPLY WITH FBC SEC.2509.2, | | | 2509.3. | | | 2) INDICATE ON THE PLAN IF EITHER THE SIDEWALL OR THE | | | BACKWALL OF THE SHOWER IS A FIRE RATED WALL ASSEMBLY | | | AND THE FIRE RATING OF EACH. IF EITHER OF THESE WALLS | | | ARE FIRE RATED, SUBMIT AN APPROVED FIRE RATED ASSEMBLY | | | FOR THE REPLACEMENT OF WALL(S). COMPLY WITH FBC SEC. | | | 708. | | | 3) INDICATE ON THE PAN IF ANY FLOOR TILE IS BEING | | | REPLACED. IF SO SUBMIT PRODUCT SPECIFICATIONS COMPLYING | | | WITH FBC SECS. 1207.3, 603.1, 703.4, 703.4.1, 703.4.2. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-17 |
Time |
03:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-13 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2016-09-14 11:18:38 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-08-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-08-26 |
Time |
06:22 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-08-24 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2016-08-25 11:17:46 | PLUMB <5K |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-09-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-17 |
Time |
03:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-17 |
Time |
03:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-08-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-08-26 |
Time |
05:42 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-08-26 |
Time |
05:35 |
Sent To |
|
|
| Notes |
| 2016-08-26 05:42:37 | 1) THIS PLUMBING WORK CANNOT BE DONE BY A GENERAL | | | CONTRACTOR AS THIS CONTRACTOR DOES NOT HOLD A PLUMBING | | | LICENSE. SUBMIT AN APPLICATION BY AN ACTIVELY LICENSED | | | AND INSURED PLUMBING CONTRACTOR IN ACCORDANCE WITH FL. | | | STATUTE 489. | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WATER | | | HEATER. WHAT IS THE CAPACITY IN GALLONS? IS THIS AN | | | EXACT REPLACEMENT OF THE EXISTING OR IS THE GALLON | | | CAAPACITY INCREASING? IF THE GALLON CAPACITY IS | | | INCREASING ALONG THE WITH THE ELEMENT RATING OF THE | | | HEATER THEN THE ELECTRIC SUPPLY TO THE HEATER MAY HAVE | | | TO BE MODIFIED. IF THIS IS AN EXACT REPLACEMENT, THEN | | | INDICATE SUCH ON THE PLAN AND INCLUDE THE OTHER | | | REQUIRED INFO. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
|