| Plan Review Stops For Permit 16080840 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-06-27 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-06-27 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2017-06-27 17:16:04 | BUILDING REVIEW APPROVED WITH PROVISO: (NOTE: PROVIDE | | | INFORMATION PRIOR TO INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS) | | | 1- INFORMATION SHOWN ON THE FRAMING DETAIL AND WALL | | | SECTION 1/A. DON'T MATCH. REVISE AS REQUIRED TO MATCH. | | | NOTE: ENGINEER TO REVISE DETAILS AND PROVIDE NEW | | | DRAWINGS WITHOUT WHITE-OUT OR PEN HANDWRITTEN | | | INFORMATION. | | | 2- INFORMATION SHOWN ON THE FRAMING DETAIL IS NOT | | | LEGIBLE. LETTERING IS TOO SMALL. REVISE AS REQ'D. | | | PROVIDE LARGER LETTERING. | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: A) WINDOW | | | MULLIONS. B) CURRENT HURRICANE SHUTTERS. C) MASTER | | | BEDROOM EXTERIOR SWING DOOR. PROVIDE COMPLETE PRODUCT | | | APPROVAL, INCLUDING THE FLORIDA PRODUCT APPROVAL COVER | | | PAGE. | | | 4- ENGINEER OF RECORD TO APPROVE IN WRITING ABOVE | | | PRODUCT APPROVALS. | | | 5- PROVIDE COMPLETE HURRICANE SHUTTERS INSTALLATION | | | SCHEDULE (2 COPIES). SEE CITY SAMPLE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-04 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-04 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2017-05-04 07:50:26 | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION, SECOND | | | BUILDING REVIEW CHECKLIST. | | | CODE: FBC 5TH EDITION (2014) | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS THAT PERMIT MAY BE ISSUED AND CONTRACTOR MAY | | | SUBMIT THE REQUIRED ITEMS AFTER THE PERMIT IS ISSUED | | | BUT BEFORE INSPECTIONS TO AVOID CONFLICTS/DELAYS. NOTE: | | | REVISION FEES MAY APPLY. CONTRACTOR TO RESPOND IN | | | WRITING IF THE PROVISO OPTION IS PREFERRED AT THIS | | | TIME. PERMIT MAY BE PROCESSED ONCE THE ENERGY | | | CALCULATIONS ARE SIGNED BY THE OWNER/AGENT, CONTRACTOR | | | COMPLETES THE EPL FORM AND THE COUNTY IMPACT FEES STAMP | | | AND PAID RECEIPT (IF REQUIRED) IS PROVIDED. | | | | | | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | RESPONSE: A) CONTRACTOR TO COMPLETE THE ENERGY | | | PERFORMANCE LEVEL (EPL) CARD AS REQUIRED BY SEC. | | | R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | B) OWNER OR LEGALLY DESIGNATED AGENT TO CERTIFY AT THE | | | BOTTOM OF THE ENERGY CALCULATIONS FORM SUBMITTED AS | | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | | 5TH EDITION (2014). | | | | | | C) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING THE BUILDER NAME. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | 2- INFORMATION SHOWN ON THE NEW "TYPICAL FRAMING AND | | | CONNECTIONS @ OPENINGS" DETAIL DOESN'T MATCH | | | INFORMATION SHOWN ON THE WALL SECTION 1/A. REVISE AS | | | REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 3- INFORMATION SHOWN ON THE NEW "TYPICAL FRAMING AND | | | CONNECTIONS @ OPENINGS" DETAIL IS NOT LEGIBLE. | | | LETTERING IS TOO SMALL TO READ AND IS NO ADEQUATE FOR | | | RECORDS RETENTION SCANNING. SEC. 107.2.1 AND SEC. | | | 107.2.1.4 CITY AMENDMENTS. REVISE AS REQUIRED. | | | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3 FOR: | | | A) WINDOW MULLIONS AS SHOWN ON PLANS. | | | RESPONSE: REPEAT COMMENT. | | | | | | B) NOA 12-0809.04 SUBMITTED FOR HURRICANE SHUTTERS | | | EXPIRED ON 04/18/2017. PROVIDE 2 COPIES OF CURRENT NOA. | | | | | | C) NEW MASTER BEDROOM EXTERIOR SWING DOOR. PROVIDE | | | FLORIDA PRODUCT APPROVAL COVER PAGE THAT CORRESPOND TO | | | DRAWINGS SUBMITTED. | | | RESPONSE: REPEAT COMMENT. | | | | | | 5- ENGINEER OF RECORD TO APPROVE IN WRITING ABOVE | | | PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | | | | 6- PROVIDE COMPLETE HURRICANE SHUTTERS INSTALLATION | | | SCHEDULE (2 COPIES). SEE CITY SAMPLE. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | RESPONSE: REPEAT COMMENT. | | | | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-04-25 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-04-25 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2017-04-25 09:38:14 | PLAN REVIEW FEES WERE NOT PAID. PLAN REVIEW FEES NEED | | | TO BE PAID AT TIME OF PERMIT APPLICATION SUBMITTAL. | | | PLAN REVIEW WILL NOT BE DONE UNTIL FEES ARE PAID. | | | CONTRACTOR TO ADVICE WHEN THE FEES ARE PAID TO RESUME | | | PLAN REVIEW CYCLE. | | | THANK YOU. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-15 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-15 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2016-09-15 08:54:57 | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION, BUILDING | | | REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014) | | | | | | ***NOTE: | | | CONTRACTOR NEEDS TO UPDATE THE LICENSE STATUS WITH THE | | | DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION | | | (DBPR). | | | | | | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | NOTE: THIS MAY BE DONE LATER WHEN THE PERMIT IS READY | | | TO BE PRINTED. | | | | | | 2- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED | | | BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | 3- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | | FOR THE NEW EXTERIOR DOOR AND WINDOWS. SEC. R301.1 | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | 4- PROVIDE COMPLETE SPECIFICATIONS FOR THE WALL | | | SHEATHING FASTENING AND EXTERIOR FINISH. SEC. R301.1 | | | FBC-RESIDENTIAL. | | | | | | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) WINDOW MULLIONS AS SHOWN ON PLANS. NOTE: CLEARLY | | | SPECIFY MULLION SIZE TO BE USED TO VERIFY COMPLIANCE | | | WITH THE CALCULATED DESIGN PRESSURES. SEC. R301.1 | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | B) WINDOW PRODUCT APPROVAL NOA 14-0722.07 SUBMITTED IS | | | FOR NON-IMPACT WINDOWS. THEREFORE NEED TO PROVIDE | | | PRODUCT APPROVAL FOR HURRICANE SHUTTERS. AND PROVIDE | | | COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | | | | C) NEW MASTER BEDROOM EXTERIOR SWING DOOR. PROVIDE | | | FLORIDA PRODUCT APPROVAL COVER PAGE THAT CORRESPOND TO | | | DRAWINGS SUBMITTED. | | | | | | D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS | | | AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT | | | APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED | | | CONNECTOR OR ENGINEER TO LIST THE CURRENT FLORIDA | | | PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED | | | CONNECTOR. | | | | | | 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ( NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-04-05 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-04-05 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-04-05 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-08-29 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-08-29 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-08-29 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-06-27 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-06-26 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2017-06-27 09:18:05 | IMPACT FEES ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-04 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-03 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2017-05-04 07:43:21 | MET WITH REGINALD. $75.00 PLAN REVIEW FEES WERE PAID. | | | OK TO RESUME PLAN REVIEWS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-04-25 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-03-29 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-21 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-08-19 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-06-27 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-06-27 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2017-06-27 17:05:45 | $1,101.25 PAID. MU-2017-014548. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-04 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-04 |
Time |
08:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-15 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-15 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2016-09-15 08:55:43 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-06-27 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-06-27 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2017-06-27 17:59:44 | MECHANICAL REVIEW APPROVED WITH PROVISO: (NOTE: PROVIDE | | | INFORMATION PRIOR TO INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS) | | | 1- MASTER BEDROOM A/C PLAN NEEDS TO SHOW COMPLIANCE | | | WITH THE BALANCED RETURN AIR AS REQUIRED BY SEC. | | | M1602.4 FBC-RESIDENTIAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-04 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-04 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2017-05-04 11:42:32 | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION SECOND | | | MECHANICAL REVIEW CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | NOTE: | | | MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS THAT PERMIT MAY BE ISSUED AND CONTRACTOR MAY | | | SUBMIT THE REQUIRED ITEMS AFTER THE PERMIT IS ISSUED | | | BUT BEFORE INSPECTIONS TO AVOID CONFLICTS/DELAYS. NOTE: | | | REVISION FEES APPLY. CONTRACTOR TO RESPOND IN WRITING | | | IF THE PROVISO OPTION IS PREFERRED AT THIS TIME. | | | | | | 1- PLANS DON'T SPECIFY IF A/C EQUIPMENT IS EXISTING OR | | | NEW. IT DOESN'T SPECIFY SIZE OF EQUIPMENT. PROVIDE | | | EQUIPMENT SIZING CALCULATIONS AS REQUIRED BY SEC. | | | R403.6 FBC-ENERGY CONSERVATION, 5TH EDITION (2014) TO | | | VERIFY COMPLIANCE WITH THE ADDITIONAL LOAD. | | | RESPONSE: PLANS ARE NOT CLEAR IF THE EXISTING A/C UNIT | | | NEEDS TO BE UPDATED TO SERVE THE ADDITIONAL LOAD. | | | CLEARLY SPECIFY ON PLANS IF THE A/C UNIT WAS UPDATED | | | AND SPECIFY ON PLANS EQUIPMENT LISTED IN THE EQUIPMENT | | | SIZING CALCULATIONS SUBMITTED. | | | | | | 2- A/C PLANS NEEDS TO SHOW COMPLIANCE WITH THE BALANCED | | | RETURN AIR AS REQUIRED BY SEC. M1602.4 FBC-RESIDENTIAL, | | | 5TH EDITION (2014). NOTE: TAKE INTO CONSIDERATION THAT | | | NEED TO COUNT ALL THE SUPPLY AIR GOING TO THE MASTER | | | BEDROOM, INCLUDING THE SUPPLY AIR TO THE UTILITY AREA | | | AND BATHROOM. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-04-25 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-04-25 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2017-04-25 16:09:49 | PLAN REVIEW FEES WERE NOT PAID. PLAN REVIEW FEES NEED | | | TO BE PAID AT TIME OF PERMIT APPLICATION SUBMITTAL. | | | PLAN REVIEW WILL NOT BE DONE UNTIL FEES ARE PAID. | | | CONTRACTOR TO ADVICE WHEN THE FEES ARE PAID TO RESUME | | | PLAN REVIEW CYCLE. | | | THANK YOU. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-09-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-19 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-19 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2016-09-19 17:23:40 | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION MECHANICAL | | | REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- PLANS DON'T SPECIFY IF A/C EQUIPMENT IS EXISTING OR | | | NEW. IT DOESN'T SPECIFY SIZE OF EQUIPMENT. PROVIDE | | | EQUIPMENT SIZING CALCULATIONS AS REQUIRED BY SEC. | | | R403.6 FBC-ENERGY CONSERVATION, 5TH EDITION (2014) TO | | | VERIFY COMPLIANCE WITH THE ADDITIONAL LOAD. | | | | | | 2- A/C PLANS NEEDS TO SHOW COMPLIANCE WITH THE BALANCED | | | RETURN AIR AS REQUIRED BY SEC. M1602.4 FBC-RESIDENTIAL, | | | 5TH EDITION (2014). NOTE: TAKE INTO CONSIDERATION THAT | | | NEED TO COUNT ALL THE SUPPLY AIR GOING TO THE MASTER | | | BEDROOM, INCLUDING THE SUPPLY AIR TO THE UTILITY AREA | | | AND BATHROOM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-04-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-21 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-21 |
Time |
12:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-09-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-21 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-21 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-04-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-04-07 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-09-19 |
|
|
Cont ID |
|
| Sent By |
pgrehic |
Date |
2016-09-19 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2016-09-19 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|