Plan Review Details - Permit 16080805
Plan Review Stops For Permit 16080805
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-11-04 Cont ID  
Sent By cthroop Date 2016-11-04 Time 15:40 Rev Time 0.00
Received By cthroop Date 2016-11-04 Time 15:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-09-15 Cont ID  
Sent By cthroop Date 2016-09-15 Time 08:24 Rev Time 0.00
Received By cthroop Date 2016-09-14 Time 15:24 Sent To  
Notes
2016-09-15 08:34:20BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
  
 DEFICIENT APPLICATION
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
  
 1. PROVIDE FLOOR PLAN IDENTIFYING LOCATION OF NEW
 SLIDING GLASS DOORS.
 2. PROVIDE DESIGN WIND LOAD FOR DOOR OPENINGS.
 3. DESIGNER TO PRINT NAME AND SIGN PLAN.
 4. PROVIDE DETAIL OF CONCRETE SLAB OVER POUR.
 5. INCREASE IN "CONDITIONED SPACE" REQUIRES MECHANICAL
 PERMIT. PLEASE SUBMIT ENERGY CALCULATIONS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-11-04 Cont ID  
Sent By vperez Date 2016-11-04 Time 15:13 Rev Time 0.00
Received By vperez Date 2016-10-27 Time 19:57 Sent To  
Notes
2016-11-04 15:24:23SEE M ALBARRAN APPROVAL PROVISO. HE SIGNED ON I ITEM

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-08-30 Cont ID  
Sent By albarran Date 2016-08-30 Time 19:20 Rev Time 0.00
Received By albarran Date 2016-08-30 Time 18:26 Sent To  
Notes
2016-08-30 19:35:24ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 PROJECT NAME: HEATHERS
 JOB ADDRESS: 7905 PINE ISLAND WAY
 DESCRIPTION: RAISE FLOOR AND BRING ELECTRIC TO CODE &
 INSTALL SLIDING GLASS DOORS
 MASTER PERMIT: 16080805
  
 1. YOU SHALL PROVIDE AN ELECTRICAL FLOOR PLAN
 INDICATING THE REQUIRED RECEPTACLES, AND LIGHTING
 OUTLETS.
 2. YOU SHALL COME INTO COMPLIANCE WITH SMOKE DETECTOR
 REQUIREMENTS AS FOR A NEW HOME.
 3. YOU SHALL INSTALL TAMPER-RESISTANT RECEPTACLES AND
 ARC-FAULT CIRCUIT PROTECTION FOR ALL NEW WIRING.
 4. SECTION 107.2.1 OF THE WPB CITY AMENDMENTS REQUIRE
 THAT THE CONSTRUCTION DOCUMENTS BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE PROPOSED WORK AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO CODE REQUIREMENTS. (CLEARLY DEFINE YOUR
 SCOPE OF WORK ON THE PLANS). SUCH DRAWINGS SHALL
 INDICATE THE APPLICABLE DESIGN CODE, AND FURTHERMORE,
 THE DRAWINGS SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN. (YOUR NAME AND
 SIGNATURE SHALL APPEAR ON ALL DOCUMENTS).
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-11-04 Cont ID  
Sent By cthroop Date 2016-11-04 Time 15:40 Rev Time 0.00
Received By cthroop Date 2016-09-22 Time 08:07 Sent To  
Notes
2016-10-31 08:08:03R06

Review Stop I INCOMING/PROCESSING
Rev No 2 Status P Date 2016-10-27 Cont ID  
Sent By albarran Date 2016-10-27 Time 20:07 Rev Time 0.00
Received By albarran Date 2016-09-22 Time 12:49 Sent To  
Notes
2016-10-27 20:09:24CONDITIONAL APPROVAL OF ELECTRIC CONTINGENT TO
 COMPLIANCE WITH NOTES ADDED TO PLANS. 1 ENCLOSED AREA
 MUST HAVE A WALL SWITCH CONTROLLED LIGHT. 2. ALL
 OUTLETS IN THE NEWLY ENCLOSED AREA SHALL COMPLY W/NEC
 406.9.
2016-09-22 12:50:00R06

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-15 Cont ID  
Sent By cpuell Date 2016-09-15 Time 17:16 Rev Time 0.00
Received By cpuell Date 2016-08-18 Time 15:01 Sent To  
Notes
2016-08-19 15:02:47R18

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2016-09-14 Cont ID  
Sent By cthroop Date 2016-09-14 Time 15:24 Rev Time 0.00
Received By cthroop Date 2016-09-14 Time 15:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-11-04 Cont ID  
Sent By cthroop Date 2016-11-04 Time 15:40 Rev Time 0.00
Received By cthroop Date 2016-11-04 Time 15:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-15 Cont ID  
Sent By jvalido Date 2016-09-15 Time 17:00 Rev Time 0.00
Received By jvalido Date 2016-09-15 Time 16:44 Sent To  
Notes
2016-09-15 16:47:54CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE MECHANICAL PLANS (IF APPLICABLE). IF NO
 HVAC MAKE NOTE ON THE FLOOR PLANS "NO HVAC WORK DONE"
  
 FLORIDA ENERGY CODE FBC 2014
  
 PROVIDE FORM R405 - 2014 AND HEAT LOAD CALCULATIONS (IF
 APPLICABLE).
  
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2016-10-26 Cont ID  
Sent By njwira Date 2016-10-26 Time 14:18 Rev Time 0.00
Received By njwira Date 2016-10-26 Time 14:18 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2016-09-26 Cont ID  
Sent By njwira Date 2016-09-26 Time 16:52 Rev Time 0.00
Received By njwira Date 2016-09-23 Time 16:03 Sent To  
Notes
2016-09-26 16:52:329/26/16- FAILED
  
 TOWNHOUSE
  
 FAILED
  
 1. REQUIRES A 10FT. SIDE SETBACK ON THE SIDE BETWEEN
 BUILDINGS.
  
 PASSED
 1. DOES PROVIDE FOR THE 6FT REAR SETBACK.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-08-22 Cont ID  
Sent By nwair Date 2016-08-22 Time 17:07 Rev Time 0.00
Received By njwira Date 2016-08-22 Time 13:56 Sent To  
Notes
2016-08-22 17:10:468/22/16
  
 LANAI PROJECTS INTO A REQUIRED SETBACK FOR A PRIMARY
 STRUCTURE.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  