Plan Review Details - Permit 16080693
Plan Review Stops For Permit 16080693
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-09-15 Cont ID  
Sent By jwitmer Date 2016-09-15 Time 17:45 Rev Time 0.00
Received By jwitmer Date 2016-09-15 Time 17:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-09-14 Cont ID  
Sent By jwitmer Date 2016-09-14 Time 12:29 Rev Time 0.00
Received By jwitmer Date 2016-09-14 Time 12:01 Sent To  
Notes
2016-09-14 12:03:07BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16080693
 ADD: 1701 S. FLAGLER DR. # 1503
 CONT: CONSULTANTS FOR CONSTRUCTION
 TEL: 561-793-8186
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. SEPT. 14/2016
 ACTION: DENIED
  
 1) 2ND REQUEST. THE SUBMITTED TEST FROM BADGER CORK/
 ACOUSTIC CORK FOR ASTM E90 & E492 INDICATE THE TEST WAS
 COMPLETED WITH A DROPPED CEILING THAT IS WHY THEY HAVE
 THE HIGHER STC AND IIC RATINGS. PLEASE GO ONLINE TO THE
 ACOUSTICCORK WEBSITE, THEY HAVE MANY PRODUCTS THAT WERE
 TESTED WITH A 6 INCH CONCRETE SLAB, NO DROP CEILING FOR
 BOTH TILE, MARBLE PRODUCT AS WELL AS WOOD AND WOOD
 LAMINATES.
  
 1ST ROUND COMMENTS. THE SUBMITTED FLOOR INSULATION
 PRODUCT QEP PREMIUM 6MM CORK UNDERLAYMENT DOES NOT HAVE
 TESTING FOR FLAME SPREAD. THE SUBMITTAL OF BADGER CORK
 FLAME SPRAD TESTING CAN ONLY BE USED WHO BOUGHT OUT
 BADGER CORK WHICH IS THE PARENT COMPANY AMORIM CORK
 COM[POSITES AND THE PRODUCT SOLD UNDER THE NAME
 ACOUSTICORK.
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILINGS:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) PLEASE NOTE A CGC CAN NOT DESIGN THE PRESSURES FOR
 THE REPLACEMENT OF WINDOWS ON A HIGH RISE BUILDING.
 107.3.4.3 CERTIFICATIONS BY CONTRACTORS AUTHORIZED
 UNDER THE PROVISIONS OF SECTION 489.115 FLORIDA
 STATUTES, SHALL BE CONSIDERED EQUIVALENT TO SEALED
 PLANS AND SPECIFICATIONS BY A PERSON LICENSED UNDER
 CHAPTER 471, FLORIDA STATUTES, OR CHAPTER 481 FLORIDA
 STATUTES, BY LOCAL ENFORCEMENT AGENCIES FOR PLANS
 REVIEW FOR PERMITTING PURPOSES RELATING TO COMPLIANCE
 WITH THE WIND-RESISTANCE PROVISIONS OF THE CODE OR
 ALTERNATE METHODOLOGIES APPROVED BY THE FLORIDA
 BUILDING COMMISSION FOR ONE AND TWO-FAMILY DWELLINGS.
 LOCAL ENFORCEMENT AGENCIES MAY RELY UPON SUCH
 CERTIFICATION BY CONTRACTORS THAT THE PLANS AND
 SPECIFICATIONS SUBMITTED CONFORM TO THE REQUIREMENTS OF
 THE CODE FOR WIND RESISTANCE.
 UPON GOOD CAUSE SHOWN, LOCAL GOVERNMENT CODE
 ENFORCEMENT AGENCIES MAY ACCEPT OR REJECT PLANS SEALED
 BY PERSONS LICENSED UNDER CHAPTERS 471,481 OR 489,
 FLORIDA STATUTES.
  
 3-4) COMPLIED.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-20 Cont ID  
Sent By jwitmer Date 2016-08-20 Time 11:14 Rev Time  
Received By jwitmer Date 2016-08-20 Time 10:30 Sent To  
Notes
2016-08-20 10:48:43BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16080693
 ADD: 1701 S. FLAGLER DR. # 1503
 CONT: CONSULTANTS FOR CONSTRUCTION
 TEL: 561-793-8186
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. AUGUST 20/2016
 ACTION: DENIED
  
 1) THE SUBMITTED FLOOR INSULATION PRODUCT QEP PREMIUM
 6MM CORK UNDERLAYMENT DOES NOT HAVE TESTING FOR FLAME
 SPREAD. THE SUBMITTAL OF BADGER CORK FLAME SPRAD
 TESTING CAN ONLY BE USED WHO BOUGHT OUT BADGER CORK
 WHICH IS THE PARENT COMPANY AMORIM CORK COM[POSITES AND
 THE PRODUCT SOLD UNDER THE NAME ACOUSTICORK.
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) PLEASE NOTE A CGC CAN NOT DESIGN THE PRESSURES FOR
 THE REPLACEMENT OF WINDOWS ON A HIGH RISE BUILDING.
 107.3.4.3 CERTIFICATIONS BY CONTRACTORS AUTHORIZED
 UNDER THE PROVISIONS OF SECTION 489.115 FLORIDA
 STATUTES, SHALL BE CONSIDERED EQUIVALENT TO SEALED
 PLANS AND SPECIFICATIONS BY A PERSON LICENSED UNDER
 CHAPTER 471, FLORIDA STATUTES, OR CHAPTER 481 FLORIDA
 STATUTES, BY LOCAL ENFORCEMENT AGENCIES FOR PLANS
 REVIEW FOR PERMITTING PURPOSES RELATING TO COMPLIANCE
 WITH THE WIND-RESISTANCE PROVISIONS OF THE CODE OR
 ALTERNATE METHODOLOGIES APPROVED BY THE FLORIDA
 BUILDING COMMISSION FOR ONE AND TWO-FAMILY DWELLINGS.
 LOCAL ENFORCEMENT AGENCIES MAY RELY UPON SUCH
 CERTIFICATION BY CONTRACTORS THAT THE PLANS AND
 SPECIFICATIONS SUBMITTED CONFORM TO THE REQUIREMENTS OF
 THE CODE FOR WIND RESISTANCE.
 UPON GOOD CAUSE SHOWN, LOCAL GOVERNMENT CODE
 ENFORCEMENT AGENCIES MAY ACCEPT OR REJECT PLANS SEALED
 BY PERSONS LICENSED UNDER CHAPTERS 471,481 OR 489,
 FLORIDA STATUTES.
  
 3) 2014 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 3.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 3.2. RISK CATEGORY.
  
 3.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
  
 3.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 3.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
 TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING.
 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
  
 4) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL
 APPROVAL.FL 61G1-23.015 (2) THE ARCHITECT IS
 RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL PROJECT
 DATA, REPORTS, SHOP DRAWINGS ETC..
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-19 Cont ID  
Sent By mvaldes Date 2016-09-19 Time 14:03 Rev Time 0.00
Received By mvaldes Date 2016-09-19 Time 13:40 Sent To  
Notes
2016-09-19 14:05:00REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 PASSED WITH THE FOLLOWING PROVISO
  
 1] JACUZZI GFCI OUTLET SHALL BE ACCESSIBLE 1' FROM
 PANEL DOOR. NEC 680.73

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-08-18 Cont ID  
Sent By mvaldes Date 2016-08-18 Time 14:52 Rev Time 0.00
Received By mvaldes Date 2016-08-18 Time 14:18 Sent To  
Notes
2016-08-18 14:58:39REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 1] ELECTRICAL SUB-PERMIT REQUIRED. PROVIDE AN EXISTING
 RISER-DIAGRAM AND PANEL SCHEDULE WITH LOAD CALCS. FBC
 107.3.5.3
  
 2] SHOW LOCATIONS OF GFCI RECEPTACLE OUTLETS ON THE
 KITCHEN COUNTER-TOP. NEC 210.52(C)
  
 3] SHOW LOCATIONS OF GFCI RECEPTACLE OUTLETS WITHIN 3'
 OF THE BATHROOM SINK. NEC 210.52(D)
  
 4] SMOKE ALARMS REQUIRED PER FBC-R 314 & 315. IF
 EXISTING PLEASE MAKE A NOTE.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-20 Cont ID  
Sent By gjohnson Date 2016-09-20 Time 09:57 Rev Time 0.00
Received By gjohnson Date 2016-09-09 Time 13:12 Sent To  
Notes
2016-09-09 13:12:19B09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-07 Cont ID  
Sent By gjohnson Date 2016-09-07 Time 08:28 Rev Time 0.00
Received By gjohnson Date 2016-08-17 Time 13:08 Sent To  
Notes
2016-08-17 13:09:35B40

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-09-20 Cont ID  
Sent By gjohnson Date 2016-09-20 Time 09:57 Rev Time 0.00
Received By gjohnson Date 2016-09-20 Time 09:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-09-07 Cont ID  
Sent By gjohnson Date 2016-09-07 Time 08:12 Rev Time 0.00
Received By gjohnson Date 2016-09-07 Time 08:12 Sent To  
Notes
2016-09-07 08:23:011ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. IN THE MASTER BATHROOM IS THE SHOWER PAN BEING
 REPLACED, TOILET , LAVATORY'S? WPB AMEND TO FBC 107.2.1
  
 2. IN GUEST BATHROOM IS THE TUB, TOILET LAVATORY BEING
 REPLACED ? WPB AMEND TO FBC 107.2.1
  