Plan Review Details - Permit 16080670
Plan Review Stops For Permit 16080670
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-14 Cont ID  
Sent By rmcdouga Date 2016-09-14 Time 15:37 Rev Time 0.00
Received By rmcdouga Date 2016-09-14 Time 15:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-08-30 Cont ID  
Sent By rmcdouga Date 2016-08-29 Time 18:59 Rev Time 0.00
Received By rmcdouga Date 2016-08-29 Time 18:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-14 Cont ID  
Sent By mvaldes Date 2016-09-14 Time 09:19 Rev Time 0.00
Received By mvaldes Date 2016-09-14 Time 09:04 Sent To B
Notes
2016-09-14 09:20:10ROUTED TO RM

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-08-18 Cont ID  
Sent By mvaldes Date 2016-08-18 Time 18:37 Rev Time 0.00
Received By mvaldes Date 2016-08-18 Time 18:04 Sent To  
Notes
2016-08-18 18:47:54REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
  
 1] CLARIFY HOW ALL UNGROUNDED AND GROUNDED FEEDER
 CONDUCTORS WILL FIT IN A 1/2'' CONDUIT ? PLEASE LOOK AT
 CONDUIT FILL TABLES AND ANNEXES.( # 6 AWG, 10 AWG )
  
 2] PROVIDE HEATER MANUFACTURE SPECS (GAS OR ELECTRIC) ?
 OTHERWISE IN ORDER TO VERIFY POOL PANEL IS ADEQUATE TO
 HANDLE LOADS PROVIDE EXISTING LOAD CALCS. FBC 107
  
 3] ALL POOL HEATERS SHALL BE EQUIPPED WITH ON-OFF
 CONTROL AND A TIME SWITCH PER FBC-E SECTION R4039.1 &
 R4039.2

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-08-20 Cont ID  
Sent By tklarge Date 2016-08-20 Time 05:10 Rev Time 0.00
Received By tklarge Date 2016-08-20 Time 05:10 Sent To  
Notes
2016-08-20 05:10:51THERE IS NO GAS ON THIS POOL.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-14 Cont ID  
Sent By rmcdouga Date 2016-09-14 Time 15:37 Rev Time 0.00
Received By rmcdouga Date 2016-09-02 Time 15:03 Sent To  
Notes
2016-09-02 15:03:33RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-30 Cont ID  
Sent By rmcdouga Date 2016-08-30 Time 07:06 Rev Time 0.00
Received By rmcdouga Date 2016-08-16 Time 15:23 Sent To  
Notes
2016-08-16 15:23:38ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-09-14 Cont ID  
Sent By rmcdouga Date 2016-09-14 Time 15:37 Rev Time 0.00
Received By rmcdouga Date 2016-09-14 Time 15:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-08-20 Cont ID  
Sent By tklarge Date 2016-08-20 Time 05:10 Rev Time 0.00
Received By tklarge Date 2016-08-20 Time 04:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-09-08 Cont ID  
Sent By njwira Date 2016-09-08 Time 16:38 Rev Time 0.00
Received By njwira Date 2016-09-06 Time 13:52 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-08-17 Cont ID  
Sent By njwira Date 2016-08-17 Time 17:16 Rev Time 0.00
Received By njwira Date 2016-08-17 Time 08:18 Sent To E
Notes
***NONE***