| Plan Review Stops For Permit 16080576 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-07 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-07 |
Time |
10:38 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-08-31 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-08-31 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-31 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2016-08-31 14:01:31 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS | | | (INCLUDING OVERHEAD GARAGE DOOR). | | | 2. PROVIDE DESIGN WIND LOADS FOR ALL NEW OPENINGS. | | | 3. PROVIDE LANDINGS AT ALL EXT DOORS. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY | | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW AND | | | DOOR SUBMITTALS. | | | | | | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | | | | R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE | | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | | MINIMUM DIMENSION OF 36 INCHES (914 MM) MEASURED IN THE | | | DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE | | | PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4 UNIT | | | VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT). | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-07 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-07 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-08-17 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-08-17 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2016-08-17 10:25:25 | JOB PERMIT NUMBER: 16080576 | | | JOB ADDRESS: 925 39TH COURT | | | WEST PALM BEACH FLORIDA | | | DATE: AUGUST 17, 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | 1) SMOKE ALARMS REQUIRED IN EACH SLEEPING ROOM, OUTSIDE | | | OF EACH SLEEPING AREA, AND ON ANY ADDITIONAL HABITABLE | | | STORY OF A DWELLING. REFLECT LOCATION ON PLANS, THEY | | | SHALL BE INTERCONNECTED AND PROTECTED BY AN ARC-FAULT | | | BKR UNLESS EXCEPTIONS APPLY. FBC-R314 | | | 2) CARBON MONOXIDE ALARMS REQUIRED WITHIN 10' OF EACH | | | SLEEPING ROOM WHERE A FOSSIL FUEL APPLIANCE, FIREPLACE, | | | OR AN ATTACHED GARAGE IS PRESENT. REFLECT LOCATION ON | | | PLANS, THEY SHALL BE INTERCONNECTED AND PROTECTED BY AN | | | ARC-FAULT BKR UNLESS EXCEPTIONS APPLY. FBC-R315 | | | 3) SHEET E-1.0, IF ON THE MASTER BATH 2 SEPARATE OR A | | | DOUBLE SINK IS GONA BE USED ADD A 20 AMP GFCI OUTLET | | | WITHIN 3' OF THE BASIN EDGE AS PER FBC-R SECTION | | | E3901.6 | | | 4) SHEET E-1.0, INSTALL A 20 AMP GFCI OUTLET WITHIN | | | 12'' OF THE TOP OF THE COUNTER-TOP ON THE KITCHEN | | | ISLAND. FBC-R SECTION E3901.4.2 | | | 5) SHEET E-1.0, GARAGE DOOR OPENER OUTLET NOT SHOWN, | | | KEEP IN MIND THE RECEPTACLE SHALL BE GFCI PROTECTED PER | | | FBC-R SECTION E3902.2 | | | 6) SHEET E-1.0, ADD A GFCI OUTLET IN THE FRONT AND BACK | | | OF THE HOUSE, PLUS THE OUTSIDE LOGGIA REQUIRES 1 | | | RECEPTACLE ACCESSIBLE WITHIN 6.5' FROM GRADE. FBC-R | | | SECTION E3901.7 | | | 7) SHEET E-1.0, LAUNDRY ROOM DOESN'T SHOW LOCATION OF | | | WASHER AND DRYER OUTLETS. KEEP IN MIND ANY ADDITIONAL | | | RECEPTACLE WITHIN THE LAUNDRY ROOM SHALL BE GFCI | | | PROTECTED. FBC-107 MINIMUM PLAN REVIEW | | | 8) PROVIDE LOCATION OF THE NEW 200 AMP PANEL ''A'' ON | | | THE FLOOR PLAN TO VERIFY WORKING CLEARANCE AND A PANEL | | | SCHEDULE WITH MATCHING CIRCUITS. FBC-107 MINIMUM PLAN | | | REVIEW. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. WHEN RESUBMITTING, FOR A | | | QUICKER RETURN ON YOUR RE-SUBMITTAL, YOU ARE REQUIRED | | | TO PROVIDE A RESPONSE LETTER (NARRATIVE) ADDRESSING | | | EACH ITEM ALONG WITH THE STANDARD CITY RE-SUBMITTAL | | | FORM. | | | THE NARRATIVE SHOULD INCLUDE THE PLAN REVIEWER'S | | | COMMENTS AND YOUR RESPONSE OR ACTION TO SAME. | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO THE | | | SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARISON. CLOUDING THE CHANGES WILL BE GREATLY | | | APPRECIATED. | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-09-08 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-09-08 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-09-08 |
Time |
08:53 |
Sent To |
B |
|
| Notes |
| 2016-09-08 08:54:22 | 9/8/16 - ALL REVISION COMMENTS ADDRESSED AND CORRECTED. | | | APPROVED PERMIT RETURNED TO BOX R03. DLE |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-08-25 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-08-25 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-08-25 |
Time |
15:01 |
Sent To |
Z |
|
| Notes |
| 2016-08-25 15:44:39 | 8/25/16 - NONCONTRIBUTING HOUSE TO NORTHWOOD HILLS HD. | | | WORK APPROVED BY HISTORIC PRESERVATION BOARD ON JUNE | | | 29, 2016. MOST CHANGES FOLLOWED ON THE PLANS BUT THE | | | FOLLOWING TWO ITEMS MUST BE ADDRESSED FOR RESUBMITTAL: | | | 1.) CURRENT PLANS SHOW ROLLING METAL GARAGE DOORS | | | WHEREAS THE HPB APPROVED CARRIAGE-STYLE DOORS, IN | | | KEEPING WITH THE DESIGN GUIDELINES OF THE HISTORIC | | | DISTRICT. | | | 2.) PROVIDE PRODUCT APPROVALS FOR THE NEW WINDOWS AND | | | DOORS. THE CONFIGURATIONS PRESENTED ON THE PLANS ARE | | | ACCURATE, BUT NO PRODUCT APPROVALS WERE SUBMITTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-16 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-15 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2016-09-16 12:42:35 | IMPACT FEES ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-09-14 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-09-07 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-01 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-09-01 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-12 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2016-08-31 18:26:19 | ROUTED TO GEORGE J. - 8/31/2014 - JORGE VALIDO | | 2016-08-15 11:16:20 | R04 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2016-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-16 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-16 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-07 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-07 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2016-09-07 10:23:45 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-08-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-08-31 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-31 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2016-08-31 13:40:37 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1. PALM BEACH COUNTY IMPACT FEES APPLY. | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-09-13 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-09-13 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-08-31 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-08-31 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-08-31 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2016-08-31 18:15:19 | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED REPLACED SHEETS DETACHED. | | | | | | | | | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | | | (1) PROVIDE ON PLANS SIZE OF DUCT FEEDING DISTRIBUTION | | | BOX FOR DUCTS FEEDING THE LAUNDRY AND CABANA BATH. | | | (2) PROVIDE FLEX DUCT SIZE FOR 2" X 48" SIDEWALL | | | FEEDING FOYER & SITTING ROOM. | | | (3) PROVIDE FLEX DUCT SIZE FOR 2" X 48" SIDEWALL | | | FEEDING THE LIVING ROOM | | | (4) PROVIDE ALL EXHAUST FANS IN BATHROOMS CFM & EXHAUST | | | DUCT SIZES. | | | (5) SHOW TERMINATION OF DRYER EXHAUST. | | | (6) SHOW LOCATION OF CONDENSING UNIT. | | | (7) PROVIDE CONDENSER TIE DOWN DETAIL AS PER FBC 2014. | | | (8) IS THERE A KITCHEN EXHAUST??? IF THERE IS PROVIDE | | | KITCHEN EXHAUST DUCT SIZING, TERMINATION AND TOTAL CFM. | | | | | | FLORIDA ENERGY CODE FBC 2014 | | | | | | (9) FORM R405-2014 MUST BE SIGNED BY OWNER/AGENT. | | | | | | JORGE VALIDO | | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | | [email protected] | | | 561-805-6716 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-09-13 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-09-13 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-09-01 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-09-01 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-09-01 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2016-09-01 10:25:37 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. LABE THEL P-TRAP LOCATED DOWN STEAM OF MASTER | | | BATHROOM ON RISER DIAGRAM. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. KITCHEN SINK IS NOT VENTED IT SHALL COMPLY WITH FBC | | | PL P3101.2.1 VENTING REQUIRED. | | | EVERY TRAP AND TRAPPED FIXTURE SHALL BE VENTED IN | | | ACCORDANCE WITH ONE OF THE VENTING METHODS SPECIFIED IN | | | THIS CHAPTER. | | | | | | 3. A CLEANOUT IS REQUIRED WHERE THE 4IN BRANCH FOR KIT | | | , LAUNDRY EXITS BUILDING BEFORE IT CONNECTS TO | | | SEWER.PER FBC PL P3005.2.7 | | | | | | 4. A TRAP PRIMER IS REQUIRED ON ALL FLOOR DRAINS. PER | | | FBC PL P3201.2 TRAP SEALS AND TRAP SEAL PROTECTION. | | | TRAPS SHALL HAVE A LIQUID SEAL NOT LESS THAN 2 INCHES | | | (51 MM) AND NOT MORE THAN 4 INCHES (102 MM). TRAPS FOR | | | FLOOR DRAINS SHALL BE FITTED WITH A TRAP PRIMER OR | | | SHALL BE OF THE DEEP SEAL DESIGN. TRAP SEAL PRIMER | | | VALVES SHALL CONNECT TO THE TRAP AT A POINT ABOVE THE | | | LEVEL OF THE TRAP SEAL. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-07 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-07 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-08-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-08-31 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-31 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2016-08-31 13:54:30 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1. ROOFING PERMIT REQUIRED. | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOF SYSTEM. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY | | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING | | | SUBMITTALS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-08-25 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-08-25 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-08-25 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2016-08-25 17:16:07 | 8/25/16- PASSED | | | | | | SF-7 SINGLE FAMILY LOW DENSITY RESIDENTIAL HISTORIC | | | | | | NO TREES CAN BE REMOVED WITHOUT A TREE ALTERATION | | | PERMIT | | | DRIVEWAY NOT INCLUDED | | | | | | 1 KITCHEN MAKES THIS ONE UNIT WHICH IS PERMITTED IN | | | THIS ZONING DISTRICT | | | FRONT SETBACK IS 36FT. MEETING THE 25FT. SETBACK | | | REQUIREMENT | | | | | | SIDE SETBACK IS 30FT 5FT. MINIMUM MEETING THE 15FT. 5FT | | | MINIMUM REQUIREMENT | | | REAR SETBACK IS 15 FT. MEETING THE 15FT. REQUIREMENT | | | | | | MEETS LOT SIZE REQUIREMENTS | | | | | | PORCH IS NOT IS A REQUIRED SETBACK | | | | | | BUILDING HEIGHT IS 20FT MEETING THE 30FT. HEIGHT LIMIT | | | | | | NO ACCESSORY STRUCTURES | | | | | | PLEASE CONTACT | | | NATHAN WIRA | | | [email protected] | | | (561)822-1442 | | | |
|
|