Plan Review Details - Permit 16080482
Plan Review Stops For Permit 16080482
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-08-15 Cont ID  
Sent By mvaldes Date 2016-08-15 Time 09:16 Rev Time 0.00
Received By mvaldes Date 2016-08-15 Time 08:49 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2016-09-01 Cont ID  
Sent By skennedy Date 2016-09-01 Time 15:21 Rev Time 0.00
Received By skennedy Date 2016-09-01 Time 15:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-29 Cont ID  
Sent By gjohnson Date 2016-08-29 Time 09:06 Rev Time 0.00
Received By gjohnson Date 2016-08-10 Time 13:04 Sent To  
Notes
2016-08-11 13:05:16C13

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-09-01 Cont ID  
Sent By skennedy Date 2016-09-01 Time 15:21 Rev Time 0.00
Received By skennedy Date 2016-09-01 Time 15:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-08-23 Cont ID  
Sent By ccole Date 2016-08-23 Time 13:43 Rev Time 0.00
Received By ccole Date 2016-08-23 Time 13:43 Sent To  
Notes
2016-08-23 14:03:081ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16080482
 8/23/16
  
 1) SHEET 3.0 MP:THE 14X6" SUPPLY TRUNKS ARE UNDERSIZED
 FOR 600 CFMS EACH- MINIMUM SIZE REQUIRED IS 14X8" BASED
 ON THE ASHRAE HANDBOOK OF FUNDAMENTALS.
  
 2) 3.0 MP: PLEASE CORRECT THE FRESH AIR CALCULATION
 SPECIFYING 2000 CFMS REQUIRED FOR THE KITCHEN. REFER TO
 TABLE 403.3 WHICH REQUIRES A 0.7 CFM PER SQ. FT.
 EXHAUST RATE FOR THE KITCHEN.
  
 3) 3.0 MP: PLEASE CLARIFY THE PURPOSE OF THE 6"
 MOTORIZED DAMPER SHOWN IN THE DINNIG ROOM. WHICH SYSTEM
 IS THE DAMPER CONNECTED TO.
  
 6) 3.0 MP: BASED ON ASHRAE STANDARD RETURN GRILL SIZING
 - 2CFMS PER SQ. IN., THE 30X8" RETURN GRILL HAS AN
 INSUFFICIENT CAPACITY OF 580 CFMS- PLEASE ENLARGE THE
 GRILL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-09-01 Cont ID  
Sent By skennedy Date 2016-09-01 Time 15:21 Rev Time 0.00
Received By skennedy Date 2016-09-01 Time 15:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-08-29 Cont ID  
Sent By gjohnson Date 2016-08-29 Time 09:01 Rev Time 0.00
Received By gjohnson Date 2016-08-26 Time 12:44 Sent To  
Notes
2016-08-29 09:06:441ST REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE A CODE COMPLAINT SET OF PLANS THAT
 SHOWS THE EXACT SCOPE OF WORK THAT WAS DONE. PER WPB
 AMEND TO FBC 107.2.1
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  