| Plan Review Stops For Permit 16080477 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-09-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-09 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-09 |
Time |
09:27 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-08-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-08-16 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-08-16 |
Time |
07:51 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-08-12 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-08-12 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-08-22 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-08-22 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2016-08-17 13:22:47 | ROUTED TO FREDERIKE MITTNER | | 2016-08-15 19:28:21 | REVISED DRAWINGS. SOUTH FACADE WAS CHANGED ON SECOND | | | FLOOR PLAN. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-09-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-14 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-14 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2016-09-14 10:20:56 | SUBMITTAL OF REVISED A/C PLAN. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-13 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-02 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2016-09-06 08:46:05 | JGOMEZ'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-08-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-08-22 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-08-11 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2016-08-11 14:50:43 | REVISION ROUTED TO VPEREZ |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-09-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-14 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-14 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-09-13 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-09-13 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2016-09-13 16:02:15 | RESIDENTIAL REVISION, THIRD MECHANICAL CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | ORIGINAL COMMENT. | | | 1- THE MASTER BEDROOM AND BEDROOM #1 ON THE SECOND | | | FLOOR DON'T COMPLY WITH THE BALANCED RETURN AIR SEC. | | | M1602.4 FBC-RESIDENTIAL, 5TH EDITION (2014). THE | | | TRANSFER GRILLES (14"X6") ARE TOO SMALL BASED ON THE | | | SUPPLY AIR. NOTE: THE MASTER BEDROOM NEEDS TO CONSIDER | | | ALL THE SUPPLY AIR, INCLUDING THE CLOSET AND BATHROOM. | | | SEE EXCEPTIONS #2 AND #3 OF SEC M1602.4 | | | FBC-RESIDENTIAL, 5TH EDITION (2014) AND REVISE PLANS AS | | | REQUIRED. | | | | | | RESPONSE: | | | (1) ALL THE SUPPLY AIR INTO THE MASTER BEDROOM, | | | INCLUDING CLOSET AND BATHROOM NEEDS TO BE CONSIDERED TO | | | SIZE THE TRANSFER GRILL. 24"X6" TRANSFER GRILL DOESN'T | | | COMPLY. SEE EXCEPTION #2 AND #3 OF SEC. M1602.4 | | | FBC-RESIDENTIAL, 5TH EDITION (2014) AND REVISE AS | | | REQUIRED. | | | | | | (2) TRANSFER GRILLES AND TRANSFER DUCTS ARE NOT THE | | | SAME. TRANSFER GRILL SIZE IS NOT DETERMINED BY THE | | | 1-1/2 TIMES THE CROSS SECTIONAL AREA. SEE EXCEPTION #1 | | | AND #2 OF SEC. M1602.4 FBC-RESIDENTIAL, 5TH EDITION | | | (2014). 14"X6" TRANSFER GRILL SPECIFIED FOR BEDROOM #1 | | | DOESN'T COMPLY. REVISE SIZE OF TRANSFER GRILL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-08-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-08-22 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-08-22 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2016-08-22 17:39:52 | RESIDENTIAL REVISION, MECHANICAL SECOND CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | 1- THE SITTING ROOM ON THE FIRST FLOOR DOESN'T COMPLY | | | WITH THE BALANCED RETURN AIR SEC. M1602.4 | | | FBC-RESIDENTIAL, 5TH EDITION (2014). REVISE PLAN AS | | | REQUIRED. | | | | | | 2- THE MASTER BEDROOM AND BEDROOM #1 ON THE SECOND | | | FLOOR DON'T COMPLY WITH THE BALANCED RETURN AIR SEC. | | | M1602.4 FBC-RESIDENTIAL, 5TH EDITION (2014). THE | | | TRANSFER GRILLES (14"X6") ARE TOO SMALL BASED ON THE | | | SUPPLY AIR. NOTE: THE MASTER BEDROOM NEEDS TO CONSIDER | | | ALL THE SUPPLY AIR, INCLUDING THE CLOSET AND BATHROOM. | | | SEE EXCEPTIONS #2 AND #3 OF SEC M1602.4 | | | FBC-RESIDENTIAL, 5TH EDITION (2014) AND REVISE PLANS AS | | | REQUIRED. | | | | | | 3- A/C COMPRESSOR DETAIL SPECIFIES FLORIDA PRODUCT | | | APPROVAL FL14239 FOR THE HOLD DOWN CLIPS. INFORMATION | | | SPECIFIED DON'T MATCH INFORMATION SHOWN ON THE FLORIDA | | | PRODUCT APPROVAL. REVISE CONNECTORS TYPE, SIZE, | | | EMBEDMENT INTO CONCRETE AND CORNER DISTANCE. SEE | | | PRODUCT APPROVAL AND REVISE AS REQUIRED. SEC.R301.1 | | | FBC-RESIDENTIAL. | | | | | | 4- PLANS NEED THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. 107.2.1 | | | CITY AMENDMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-08-15 |
Time |
19:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-08-15 |
Time |
19:24 |
Sent To |
Z |
|
| Notes |
| 2016-08-15 19:30:39 | RESIDENTIAL REVISION, MECHANICAL REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | 1- ACCORDING TO THE DESCRIPTION ON THE REVISION FORM | | | AND FLOOR PLANS SUBMITTED A/C DUCT WORK LAYOUT AND | | | EQUIPMENT LOCATION WAS REVISED. NEED TO SUBMIT REVISED | | | MECHANICAL PLANS FOR REVIEW. PROVIDE 2 COPIES. SEC. | | | 107.3.5.3(10) CITY AMENDMENTS. | | | | | | 2- ACCORDING TO CITY RECORDS, THERE IS NO MECHANICAL | | | PERMIT FOR THE A/C WORK. NEED MECHANICAL PERMIT AS | | | REQUIRED BY SEC. 105.1 CITY AMENDMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-08-17 |
Time |
06:00 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-08-17 |
Time |
05:51 |
Sent To |
|
|
| Notes |
|
|