Plan Review Details - Permit 16080448
| Plan Review Stops For Permit 16080448 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-09-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-29 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-29 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-08-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-08-18 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-18 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2016-08-18 11:05:56 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | DATE: 8/18/16 | | | | | | 1. PROVIDE DESIGN WIND LOAD CALCULATIONS. | | | 2. PROVIDE DIRECT BURIAL AUGER DEMENSIONS (W X D) BASED | | | ON WIND LOADS. | | | | | | | | | FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | | | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-09-29 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-29 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-29 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2016-09-29 14:07:37 | ROUTED TO CT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-08-18 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-08-18 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-08-18 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2016-08-18 10:36:12 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | - PROVIDE PHOTOMETRICS TO COMPLY WITH MINIMUM | | | ILLUMINATION LEVELS AND EXTERIOR BUILDING LIGHTING | | | ENERGY ALLOWANCES. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-29 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-28 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2016-09-28 14:10:54 | RESUB ROUTED TO MVALDES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-08-17 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-08-10 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2016-08-10 13:00:55 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-08-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-08-10 |
Time |
17:15 |
Sent To |
E |
|
| Notes |
|
|
|